China KGD - WQ - 502 Engine Exhaust Full - Flow Dilution Constant - Volume Sampling
China KGD - WQ - 502 Engine Exhaust Full - Flow Dilution Constant - Volume Sampling

  1. China KGD - WQ - 502 Engine Exhaust Full - Flow Dilution Constant - Volume Sampling

KGD - WQ - 502 Engine Exhaust Full - Flow Dilution Constant - Volume Sampling

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
System Accuracy ≤ ±2% (Checked by propane injection)
Diluted Exhaust Flow Rate 1 - 12 m³/min; 3 - 24 m³/min; 9 - 60 m³/min; 30 - 150 m³/min
Diluted Exhaust Temperature Control 40 ± 5 °C
Gas Bag Sampling Flow Rate 3 L/min, 6 L/min or 9 L/min
Number of Gas Bags 3 diluted air gas bags, 3 diluted exhaust gas bags
Gas Bag Cabinet Temperature Control 35 ± 5 °C
Brand Name KACISE
Model Number KGD-WQ-502
Certification CE
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
System Accuracy ≤ ±2% (Checked by propane injection) Diluted Exhaust Flow Rate 1 - 12 m³/min; 3 - 24 m³/min; 9 - 60 m³/min; 30 - 150 m³/min
Diluted Exhaust Temperature Control 40 ± 5 °C Gas Bag Sampling Flow Rate 3 L/min, 6 L/min or 9 L/min
Number of Gas Bags 3 diluted air gas bags, 3 diluted exhaust gas bags Gas Bag Cabinet Temperature Control 35 ± 5 °C
Brand Name KACISE Model Number KGD-WQ-502
Certification CE Place of Origin CHINA
High Light KGD Engine Exhaust Sampling SystemWQ 502 Engine Exhaust Sampling System

KGD - WQ - 502 Engine Exhaust Full - flow Dilution Constant - volume Sampling System

Product Introduction

The KGD - WQ - 502 Engine Exhaust Full - flow Dilution Constant - volume Sampling System is specifically designed for measuring the diluted emissions of vehicles and engines. It features a fully - functional and technologically - advanced hardware configuration and software platform. When used in conjunction with high - precision gas and particle online analyzers, it can meet the requirements of current major mobile source emission standards and Euro 7 emission standards for laboratory Type I emission tests.

Product Features

  • Offers a wide range of diluted exhaust flow rate options to meet the testing needs of engines and vehicles with various fuels and displacements.
  • Through the combination of a high - performance heat exchanger and a Venturi tube, it can accurately control the diluted exhaust flow rate and ensure the accuracy and stability of the system.
  • Thanks to the constant - temperature control functions of the heat exchanger and the gas bag cabinet, it can effectively prevent the condensation of diluted exhaust.
  • Equipped with a high - performance diluted air filtration device to meet the emission test requirements for ultra - low emission levels.

Technical Parameters

Parameter Details
System Accuracy ≤ ±2% (Checked by propane injection)
Diluted Exhaust Flow Rate 1 - 12 m³/min; 3 - 24 m³/min; 9 - 60 m³/min; 30 - 150 m³/min
Diluted Exhaust Temperature Control 40 ± 5 °C
Gas Bag Sampling Flow Rate 3 L/min, 6 L/min or 9 L/min
Number of Gas Bags 3 diluted air gas bags, 3 diluted exhaust gas bags
Gas Bag Cabinet Temperature Control 35 ± 5 °C
Particle Sampling Flow Rate 35 - 65 L/min
Number of Particle Sampling Channels 3 diluted exhaust sampling channels, 1 diluted air sampling channel
Particle Sampling Box Temperature Control 47 ± 5 °C
Diluted Air Filtration Device Activated carbon filter, pre - filter, and H13 - grade high - efficiency filter
Application Environment Ambient temperature 5 - 35 °C; Ambient humidity ≤ 80%RH; Atmospheric pressure 80 - 102 kPa

 


 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement