China KGD - WQ - 502 Engine Exhaust Full - Flow Dilution Constant - Volume Sampling
China KGD - WQ - 502 Engine Exhaust Full - Flow Dilution Constant - Volume Sampling

  1. China KGD - WQ - 502 Engine Exhaust Full - Flow Dilution Constant - Volume Sampling

KGD - WQ - 502 Engine Exhaust Full - Flow Dilution Constant - Volume Sampling

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
System Accuracy ≤ ±2% (Checked by propane injection)
Diluted Exhaust Flow Rate 1 - 12 m³/min; 3 - 24 m³/min; 9 - 60 m³/min; 30 - 150 m³/min
Diluted Exhaust Temperature Control 40 ± 5 °C
Gas Bag Sampling Flow Rate 3 L/min, 6 L/min or 9 L/min
Number of Gas Bags 3 diluted air gas bags, 3 diluted exhaust gas bags
Gas Bag Cabinet Temperature Control 35 ± 5 °C
Brand Name KACISE
Model Number KGD-WQ-502
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
System Accuracy ≤ ±2% (Checked by propane injection) Diluted Exhaust Flow Rate 1 - 12 m³/min; 3 - 24 m³/min; 9 - 60 m³/min; 30 - 150 m³/min
Diluted Exhaust Temperature Control 40 ± 5 °C Gas Bag Sampling Flow Rate 3 L/min, 6 L/min or 9 L/min
Number of Gas Bags 3 diluted air gas bags, 3 diluted exhaust gas bags Gas Bag Cabinet Temperature Control 35 ± 5 °C
Brand Name KACISE Model Number KGD-WQ-502
Certification CE Place of Origin CHINA
High Light KGD Engine Exhaust Sampling SystemWQ 502 Engine Exhaust Sampling System

KGD - WQ - 502 Engine Exhaust Full - flow Dilution Constant - volume Sampling System

Product Introduction

The KGD - WQ - 502 Engine Exhaust Full - flow Dilution Constant - volume Sampling System is specifically designed for measuring the diluted emissions of vehicles and engines. It features a fully - functional and technologically - advanced hardware configuration and software platform. When used in conjunction with high - precision gas and particle online analyzers, it can meet the requirements of current major mobile source emission standards and Euro 7 emission standards for laboratory Type I emission tests.

Product Features

  • Offers a wide range of diluted exhaust flow rate options to meet the testing needs of engines and vehicles with various fuels and displacements.
  • Through the combination of a high - performance heat exchanger and a Venturi tube, it can accurately control the diluted exhaust flow rate and ensure the accuracy and stability of the system.
  • Thanks to the constant - temperature control functions of the heat exchanger and the gas bag cabinet, it can effectively prevent the condensation of diluted exhaust.
  • Equipped with a high - performance diluted air filtration device to meet the emission test requirements for ultra - low emission levels.

Technical Parameters

Parameter Details
System Accuracy ≤ ±2% (Checked by propane injection)
Diluted Exhaust Flow Rate 1 - 12 m³/min; 3 - 24 m³/min; 9 - 60 m³/min; 30 - 150 m³/min
Diluted Exhaust Temperature Control 40 ± 5 °C
Gas Bag Sampling Flow Rate 3 L/min, 6 L/min or 9 L/min
Number of Gas Bags 3 diluted air gas bags, 3 diluted exhaust gas bags
Gas Bag Cabinet Temperature Control 35 ± 5 °C
Particle Sampling Flow Rate 35 - 65 L/min
Number of Particle Sampling Channels 3 diluted exhaust sampling channels, 1 diluted air sampling channel
Particle Sampling Box Temperature Control 47 ± 5 °C
Diluted Air Filtration Device Activated carbon filter, pre - filter, and H13 - grade high - efficiency filter
Application Environment Ambient temperature 5 - 35 °C; Ambient humidity ≤ 80%RH; Atmospheric pressure 80 - 102 kPa

 


 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement