China KGD-WQ-504 Portable Emission Testing System (PEMS) with Real-time Measurement
China KGD-WQ-504 Portable Emission Testing System (PEMS) with Real-time Measurement

  1. China KGD-WQ-504 Portable Emission Testing System (PEMS) with Real-time Measurement

KGD-WQ-504 Portable Emission Testing System (PEMS) with Real-time Measurement

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Repeatability ≤ ±0.5% F.S.
Drift ≤ ±1% F.S./8h
VPR Removal Efficiency >99.0% (C40)
Minimum Particle Size Limit 23 nm or 10 nm
Measurement Principle Electrical charge counting method
Measuring Range 600 - 1.3×10⁹ #/cm³
Brand Name KACISE
Model Number KGD-WQ-504
Certification CE
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Repeatability ≤ ±0.5% F.S. Drift ≤ ±1% F.S./8h
VPR Removal Efficiency >99.0% (C40) Minimum Particle Size Limit 23 nm or 10 nm
Measurement Principle Electrical charge counting method Measuring Range 600 - 1.3×10⁹ #/cm³
Brand Name KACISE Model Number KGD-WQ-504
Certification CE Place of Origin CHINA
High Light PEMS Portable Emission Testing SystemKGD-WQ-504 Emission Testing SystemKGD-WQ-504 Portable Emission Testing System
KGD-WQ-504 Portable Emission Testing System (PEMS)
Product Overview

The KGD-WQ-504 Portable Emission Testing System is specifically designed for in-use vehicle on-road emission tests. It can continuously and real-time measure or collect volume concentrations of air pollutants including CO, CO₂, NO, NO₂, NOₓ, O₂, and THC, as well as particulate matter number concentration, exhaust gas flow, global positioning data, meteorological data, and OBD parameters.

The system features test process guidance, automatic calculation of total emissions, and export of test reports, meeting certification tests, in-use compliance tests, and related research and development test requirements for global vehicle on-road emission regulations.

KGD-WQ-504 Portable Emission Testing System
Product Features
  • Core sensing technology under independent control
  • One-stop service throughout the entire life cycle
  • Small in size, light in weight, and low energy consumption
  • Easy to install and use with lithium-ion battery life exceeding 8 hours
  • Modular design with plug-and-play functionality
  • Flexibly meets various regulatory and R&D test requirements
  • High-standard waterproof and shockproof construction
  • Maintains stable test performance under various harsh working conditions
Technical Specifications
Host System - Gas Analyzers
Gas Component CO CO₂ NO NO₂
Measurement Principle NDIR NDIR NDUV NDUV
Measuring Range 0 - 0.5 - 5% 0 - 5 - 20% 0 - 3000 ppm 0 - 1000 ppm
Common Specifications
Response Time T10-90 < 2.5s
Accuracy ≤ ±2.0%RS or ≤ ±0.3%FS
Linearity Determination coefficient: ≥ 0.998; Standard deviation: ≤ 1% F.S.; Slope: 0.99-1.01; Intercept coefficient: ≤ 0.5% F.S.
Repeatability ≤ ±0.5% F.S.
Drift ≤ ±1% F.S./8h
Operating Environment Operating temperature: -10 to 45°C; Relative humidity: ≤ 90%RH; Altitude: 0-3000m
Exhaust Gas Flow Measurement
Temperature Range -5 to 500°C
Exhaust Gas Temperature Measurement Accuracy ≤ ±1% reading or ± 2°C
Exhaust Gas Flow Measurement Range 10-600kg/h; 100-2000kg/h
Exhaust Gas Flow Measurement Accuracy ≤ ±2.0% reading or ≤ ±0.5% full-scale value
Exhaust Gas Flow Measurement Linearity Determination coefficient: ≥ 0.990; Standard deviation: ≤ 1% full-scale value; Slope: 0.99-1.01; Intercept coefficient: ≤ 1% full-scale value
Response Time < 1s
THC/CH₄ Analyzer
Gas Component THC THC CH₄ CH₄
Measurement Principle HFID HFID NMC-FID NMC-FID
Minimum Range 0 - 100 ppmC 0 - 100 ppmC 0 - 100 ppmC 0 - 100 ppmC
Maximum Range 0 - 10000 ppmC 0 - 10000 ppmC 0 - 3000 ppmC 0 - 3000 ppmC
Response Time T10-90 < 2.5s
Accuracy ≤ ±2.0% MRS or ≤ ±0.3% F.S.
Linearity Determination coefficient: ≥ 0.998; Standard deviation: ≤ 1% F.S.; Slope: 0.99-1.01; Intercept coefficient: ≤ 0.5% F.S.
Repeatability ≤ ±0.5% F.S.
Drift ≤ ±1% F.S./8h
PN Analyzer (Particulate Number)
Minimum Particle Size Limit 23 nm or 10 nm
Measurement Principle Electrical charge counting method
Measuring Range 600 - 1.3×10⁹ #/cm³
Measurement Accuracy ≤ ±10%
VPR Removal Efficiency >99.0% (C40)
Response Time T90 < 5s
NH₃/N₂O Analyzer
Gas Component NH₃ NH₃ N₂O N₂O
Measuring Range 0 - 1000 ppm
Response Time T10-90 < 2.5s
Accuracy ≤ ±2.0% MRS or ≤ ±0.3% F.S.
Linearity Determination coefficient: ≥ 0.998; Standard deviation: ≤ 1% F.S.; Slope: 0.99-1.01; Intercept coefficient: ≤ 0.5% F.S.
Repeatability ≤ ±0.5% F.S.
Drift ≤ ±1% F.S./8h

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • 2nd Building, Tianyuan International Mansion, High-tech Zone, Xi'an City, Shaanxi Province, China
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement