| Working temperature | -10~50℃ |
| Relative humidity | ≤97% |
| Standard of examination | GB25972-2010 |
| Capacity of cylinder | 120L |
| Pattern of extinguishing | Enclosed flooding |
| Type | Conduit |
| Payment Terms | T/T, L/C |
| Supply Ability | 30000 set system |
| Delivery Time | 15-20 working days after payment or receipt of L/C |
| Packaging Details | Plywood outer box with bubble bag or paper |
| Brand Name | xingjin |
| Certification | CAL,CMA,CNAS,ILAC-MRA,CCC |
| Place of Origin | China |
View Detail Information
Explore similar products
100L Cylinder Manual Actuation FM200 Gas Suppression System Colorless Tasteless
Totally Automatic One Zone FM200 Fire Suppression System with No Pipeline for
40L Single Cabinet FM200 Fire Extinguishing System Pipe Network FM200 Gas
Enclosed Flooding Piped FM200 Suppression System for Single Zone Protection —
Product Specification
| Working temperature | -10~50℃ | Relative humidity | ≤97% |
| Standard of examination | GB25972-2010 | Capacity of cylinder | 120L |
| Pattern of extinguishing | Enclosed flooding | Type | Conduit |
| Payment Terms | T/T, L/C | Supply Ability | 30000 set system |
| Delivery Time | 15-20 working days after payment or receipt of L/C | Packaging Details | Plywood outer box with bubble bag or paper |
| Brand Name | xingjin | Certification | CAL,CMA,CNAS,ILAC-MRA,CCC |
| Place of Origin | China | ||
| High Light | fm 200 suppression system ,firefighting equipments ,fm200 gas suppression system 120L | ||
| No. | Specification | Technical Parameter |
|---|---|---|
| 1 | Filling pressure | 4.2 MPa / 5.6 MPa |
| 2 | Scale of protective region for one zone | Area: max single-zone is 800 m² Volume: max single-zone is 3600 m³ |
| 3 | Spraying time | ≤ 10 s |
| 4 | Filling density | ≤ 950 kg/m³ / ≤ 1080 kg/m³ |
| 5 | Power | DC 24V / 1.6A |
| 6 | Nitrogen pressure of driving device | 6.0 ± 1.0 MPa (20°C) |
| 7 | Condition of reserving room for container | Temperature: -10–50°C, relative humidity: ≤ 97% |
| 8 | Max working pressure | 5.3 MPa / 8.0 MPa |
| 9 | Min working pressure | 4.2 MPa / 4.6 MPa |
Suitable for electronic computer rooms, data processing centers, telecommunications facilities, expensive medical equipment, industrial equipment, libraries, museums and art galleries, clean rooms, anechoic chambers, emergency power facilities, and flammable liquid storage areas.
Also ideal for locations where fire is likely to occur, such as paint-spraying production lines, aging electrical equipment, rolling machines, printing machines, oil switches, oil-immersed transformers, melt impregnating tanks, large generators, drying equipment, cement production processes involving pulverized coal, and ship engine rooms and cargo holds.
The FM200 Gas Suppression System formed with conduit in the 120L model is mainly composed of three parts: extinguishing devices, pipe fittings, and electrical accessories.
These include the cylinder used to fill and store FM200, the frame, and the driving device (nitrogen cylinder) that triggers the storage cylinder to discharge the agent.
These are the conduits that connect the extinguishing device and guide the agent into the protective zone, such as high-pressure galvanized steel pipes, flanges, and elbows.
These are used to detect and monitor the entire protective area and control the whole system. They also warn people to evacuate and prevent fire expansion.
These three integrated parts work together efficiently to detect, supervise, alarm, and extinguish fire automatically.
Every fire suppression system has its strong points. Below are the key advantages of the pipe network type FM200 fire suppression system.
Thanks to its structure and the assembly of other useful components, it can concentrate on one very large protection zone with the combination of multiple storage cylinders. Its coverage can also be very small with a single-cylinder system.
One set of pipe network system can achieve an even discharge across large zones in a short time with the help of the pipeline deployment.
The most distinctive and flexible advantage of this system is the combined distribution system, which combines multiple rooms in one district or building, even with different dimensions or on different floors. It reduces cost through the safe and efficient utilization of fire extinguishing gas. Selective valves guide the extinguishing gas into the room on fire, making it relatively smarter to monitor each room and avoid accidents.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
600000-1200000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro... About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro...
Get in touch with us
Leave a Message, we will call you back quickly!