| Filling Pressure | 5.6 MPa, 4.2 MPa |
| Discharge Time | ≤10s |
| Filling Density | ≤1250kg/m³ |
| Driving Device Pressure | 6.0MPa(20℃) |
| Pressure of Adding Pressure Cylinder | 13.5MPa |
| Ambient Temperature | 0~50℃ |
| Cylinder Volume | 90Ltr, 120Ltr, 150Ltr, 180Ltr, 245Ltr |
| Power | DC24V/1A |
| Payment Terms | L/C, D/P, T/T, Western Union, Paypal, Credit card |
| Supply Ability | 3000 sets per month |
| Delivery Time | 10-15 days |
| Packaging Details | Plywood outer box with bubble bag or paper |
| Brand Name | Xingjin |
| Model Number | QMQ5.6/90W-XJ, QMQ5.6/120W-XJ, QMQ5.6/150W-XJ, QMQ5.6/180W-XJ, QMQ4.2/245W-XJ |
| Certification | CAL,CMA,CNAS,ILAC-MRA,CCC |
| Place of Origin | Guangdong, China |
View Detail Information
Explore similar products
90L Cylinder Volume 13.5Mpa FM200 Piston Flow System Environmentally Friendly
90L Cylinder Volume FM200 Piston Flow System with 10s Discharge Time and 800m2
FM200 Piston Flow System Piston Flow Fire Extinguishing System with 180Ltr
High Safety FM200 Piston Flow System with 150Ltr Cylinder Volume and ≤10s
Product Specification
| Filling Pressure | 5.6 MPa, 4.2 MPa | Discharge Time | ≤10s |
| Filling Density | ≤1250kg/m³ | Driving Device Pressure | 6.0MPa(20℃) |
| Pressure of Adding Pressure Cylinder | 13.5MPa | Ambient Temperature | 0~50℃ |
| Cylinder Volume | 90Ltr, 120Ltr, 150Ltr, 180Ltr, 245Ltr | Power | DC24V/1A |
| Payment Terms | L/C, D/P, T/T, Western Union, Paypal, Credit card | Supply Ability | 3000 sets per month |
| Delivery Time | 10-15 days | Packaging Details | Plywood outer box with bubble bag or paper |
| Brand Name | Xingjin | Model Number | QMQ5.6/90W-XJ, QMQ5.6/120W-XJ, QMQ5.6/150W-XJ, QMQ5.6/180W-XJ, QMQ4.2/245W-XJ |
| Certification | CAL,CMA,CNAS,ILAC-MRA,CCC | Place of Origin | Guangdong, China |
| High Light | Piston Flow FM200 Gas Suppression System ,CCC fm 200 fire system ,Piston Flow fm 200 fire system | ||
The use of FM200 fire extinguishing agent as a fire suppressant is not prohibited by the Montreal Protocol. It is a clean agent belonging to a class of compounds introduced specifically to facilitate the phase-out of ozone-depleting gases such as Halon 1301. It is the most widely used chemical replacement for Halon 1301 and has been used successfully to help protect tens of thousands of high-technology facilities in 70 countries around the world.
The Piston Flow Type FM200 Gas Suppression System is a fire suppression system that uses a piston mechanism to discharge the FM200 gas agent quickly and effectively. The system is designed to protect critical facilities such as data centers, computer rooms, and other facilities containing valuable equipment.
The system comprises a storage container that holds the pressurized FM200 gas agent, a set of distribution piping, and a specially designed discharge head. When the system is activated, the piston mechanism is triggered, creating a pressure shock wave that pushes the FM200 gas agent through the distribution piping and into the protected area.
The FM200 gas agent effectively suppresses fire by reducing oxygen levels in the affected area, smothering the flames and preventing the fire from spreading. The system is designed to detect and suppress fire quickly, minimizing damage to equipment and facilities and reducing downtime.
The Piston Flow Type FM200 Gas Suppression System is environmentally friendly and leaves no residue behind after discharge. The system is also cost-effective to maintain and easy to install, making it an ideal fire suppression solution for critical facilities.
The system can be integrated with other fire suppression and alarm systems, providing comprehensive protection for the protected area. It is particularly useful for areas with high ceilings or where discharge piping restrictions exist, such as in large data centers or industrial locations.
Xingjin FM200 gas piston flow type fire suppression systems are ideal for use in occupied areas. Independent toxicity studies have established that the agent is low in both acute and chronic toxicity, with high safety margins between its normal use concentrations and the no observable adverse effect level (NOAEL).
| No. | Name | Specification |
|---|---|---|
| 1 | Device Model | QMQ5.6/90W-XJ, QMQ5.6/120W-XJ, QMQ5.6/150W-XJ, QMQ5.6/180W-XJ, QMQ4.2/245W-XJ |
| 2 | Cylinder Volume | 90Ltr, 120Ltr, 150Ltr, 180Ltr, 245Ltr |
| 3 | Filling Capacity of Gas | 112.5kg, 150kg, 187.5kg, 225kg, 306.25kg |
| 4 | Max Working Pressure | 8MPa, 5.3MPa |
| 5 | Max Protected Area | Single zone: 800m² |
| 6 | Max Protected Volume | Single zone: 3600m³ |
| 7 | Spraying Time | ≤10s |
| 8 | Agent Filling Density | ≤1250kg/m³ |
| 9 | Power | DC24V/1A |
| 10 | Pressure of Adding Pressure Cylinder | 13.5MPa |
| 11 | Pressure of Driving Device | 6.0MPa (20°C) |
| 12 | Condition of Reserving Room for Container | Temperature: 0~50°C |
This system mainly consists of an agent storage cylinder, container valve, driving cylinder group, adding pressure cylinder group, distributing valve, liquid flow check valve, gas flow check valve, safety valve, pressure switch, frame, nozzle, high pressure hose, pressure-relief device, level gauge, relief valve, and pipe system. These components can constitute a unit independent system. Combined distribution systems and other forms can implement fire protection for single and multiple zones.
Pipe fittings are the conduits that connect the extinguishing device and guide the agent into the protective zone, such as high-pressure galvanized steel pipe, flange, and elbow.
Electrical accessories are used to detect and monitor the entire protective area and control the whole system, as well as warn people to evacuate and prevent fire expansion.
These three integrated parts work together efficiently to detect, supervise, alarm, and extinguish fire automatically.
We always pack with polyfoam first and then place the goods into a wooden case. Sometimes, to meet customer or safety requirements, we will make a pallet for the goods.
Q: Are you a manufacturer or a trading company?
A: We are a manufacturer.
Q: Is the OEM order available?
A: Yes, we produce in accordance with each client's requirements.
Q: Where is your factory located? How can I visit there?
A: Our factory is located in Guangzhou, Guangdong Province, China. You are very welcome to visit our factory.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
600000-1200000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro... About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro...
Get in touch with us
Leave a Message, we will call you back quickly!