| Payment Terms | T/T, L/C |
| Supply Ability | 30000set/month |
| Delivery Time | 15-20days |
| Packaging Details | Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper |
| Main ingredients | Nitrogen (N2), Argon (Ar), Carbon Dioxide (CO2) |
| Operating ambient temperature | 0~50 ℃ |
| Nominal working pressure (20℃) | 15MPa |
| Maximum working pressure (20℃) | 17.2MPa |
| Storage bottle volume | 80/90L |
| Storage bottle filling volume (20℃) | 12/13.5m3 |
| System operating voltage | 220V AC,24V DC |
| System startup method | Electrical automatic, electrical manual, mechanical emergency start |
| Safety relief pressure (MPa) | 23±1.15 |
| The outlet thread of the container valve | M30×1.5 |
| Brand Name | XINGJIN |
| Model Number | IG541 |
| Certification | CCC,CAC,ROHS |
| Place of Origin | Guangzhou,China |
View Detail Information
Explore similar products
Argonite Fire Suppression System Ig55
30MPa IG541 Inergen Gas Fire Suppression System For Minimal Damage
IG55 Argonite Fire System
15MPa 80L 90L Inergen Gas Fire Suppression System Reasonable Good Price High
Product Specification
| Payment Terms | T/T, L/C | Supply Ability | 30000set/month |
| Delivery Time | 15-20days | Packaging Details | Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper |
| Main ingredients | Nitrogen (N2), Argon (Ar), Carbon Dioxide (CO2) | Operating ambient temperature | 0~50 ℃ |
| Nominal working pressure (20℃) | 15MPa | Maximum working pressure (20℃) | 17.2MPa |
| Storage bottle volume | 80/90L | Storage bottle filling volume (20℃) | 12/13.5m3 |
| System operating voltage | 220V AC,24V DC | System startup method | Electrical automatic, electrical manual, mechanical emergency start |
| Safety relief pressure (MPa) | 23±1.15 | The outlet thread of the container valve | M30×1.5 |
| Brand Name | XINGJIN | Model Number | IG541 |
| Certification | CCC,CAC,ROHS | Place of Origin | Guangzhou,China |
| High Light | IG541 fire suppression piping network ,corrosion-resistant inert gas fire system ,enclosed space fire safety pipes | ||
IG541 Mixed Gas Automatic Fire Suppression System
Product Introduction:
IG541 mixed gas extinguishing agent is a colorless, odorless, non-toxic, and non-conductive pure "green" compressed gas. It is composed of atmospheric gases—nitrogen, argon, and carbon dioxide—with abundant raw materials. During the fire extinguishing process, it does not obstruct people's vision and does not produce temperature differences or corrosive decomposition products. The release of the extinguishing agent simply returns the gases to their natural state. It has no ozone depletion potential (ODP), does not produce a "greenhouse effect," and does not produce chemical substances that damage the atmosphere. It does not cause the toxicity problems associated with halogenated alkanes and their alternative extinguishing agents during the fire extinguishing process. It is an ideal extinguishing agent suitable for places where people frequently work.
![]()
Composition and quality indicators of the mixed gas:
| Main ingredients | Nitrogen(N2) | Argon gas(Ar) | Carbon dioxide(CO2) |
| Purity requirements for each component | >99.9% | >99.9% | >99.5% |
| Moisture content requirements for each component | <5ppm | <4ppm | <10ppm |
| Oxygen content requirements for each component | <3ppm | <3ppm | <10ppm |
|
Extinguishing Principle of the Extinguishing Agent: The extinguishing principle of the IG541 gas mixture is primarily to reduce the oxygen concentration (below 15%) to inhibit combustion and thus extinguish the fire. It can extinguish Class A surface fires, Class B flammable liquid fires, and fires involving energized electrical equipment in enclosed spaces using total flooding methods.
|
Product features:
MULTI ZONE PROTECTION
The conveying distance can reach over 150m
According to usage requirements, the lG541 fire extinguishing system can form a unit independentsystem and a combined distribution system, using a fully submerged method to achieve fireprotection for a single protection zone and multiple protection zones, The system has high storagepressure, and the distance from the steel cylinder to the nozzle can reach over 150M
CLEAN GAS
Colorless and non-toxicNot damaging equipment
Good electrical insulation, no harm to personnel at the sceneof a fire, lt can be started in automatically, manually ormechanical emergency mode according to the needs of different occaslon.
Technical Parameters:
IG541 FIRE EXTINGUISHING SYSTEMMIXED GAS EXTINGUISHING AGENT
The lG541 mixed gas fire extinguishing system generally consists of a mixtureof 52% nitrogen40% gas, and 8% carbon dioxide, with a lower cost thanHFC-227ea, After spraying, it will not cause a sharp drop in temperature in theprotective zone, and will not cause any harm to precision equipment and otherprecious properties
| Operating ambient temperature: ℃ | 0~50 | ||
|
Work
Pressure |
Nominal work pressure(20℃)MPa | 15 | |
| Maximum working pressure(20℃)MPa | 17.2 | ||
| Minimum working pressure(20℃)MPa | 13.6 | ||
| Storage bottle volumeL | 80 | 90 | |
| Storage bottle filling capacity(20℃)m3 | 12 | 13.5 | |
| System operating voltage | 220V AC,24V DC | ||
| System startup mode | Electrical automatic, electrical manual, mechanical emergency start | ||
|
Fire extinguishing Concentration |
Extinguish Class A solid surface fires | 28.1% | |
| Extinguish Class B liquid fires | 33.8% | ||
|
Design concentration |
Extinguish Class A solid surface fires | 36.5% | |
| Extinguish Class B liquid fires | 43.9% | ||
| The design concentration in a workplace where people are present | 37.5~43% | ||
The extinguishing principle of the IG541 gas mixture is primarily to reduce the oxygen concentration (below 15%) to inhibit combustion and thus extinguish the fire. It can extinguish Class A surface fires, Class B flammable liquid fires, and fires involving energized electrical equipment in enclosed spaces using total flooding methods.
Application Locations:
Computer rooms, communication equipment rooms, transformer rooms, electrical switch and distribution rooms, generator rooms, oil immersion tanks, drying equipment, paint booths, electrical instrument rooms, control centers, libraries and archives, and cultural relic storage facilities, etc.
![]()
![]()
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
600000-1200000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro... About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro...
Get in touch with us
Leave a Message, we will call you back quickly!