China factories

Chat Now Send Email
China factory - Guangzhou Xingjin Fire Equipment Co.,Ltd.

Guangzhou Xingjin Fire Equipment Co.,Ltd.

  • China,Guangzhou ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Self-Actuating Fire Suppression Tube Automatic Fire Extinguishing Device for
China Self-Actuating Fire Suppression Tube Automatic Fire Extinguishing Device for

  1. China Self-Actuating Fire Suppression Tube Automatic Fire Extinguishing Device for
  2. China Self-Actuating Fire Suppression Tube Automatic Fire Extinguishing Device for
  3. China Self-Actuating Fire Suppression Tube Automatic Fire Extinguishing Device for
  4. China Self-Actuating Fire Suppression Tube Automatic Fire Extinguishing Device for
  5. China Self-Actuating Fire Suppression Tube Automatic Fire Extinguishing Device for

Self-Actuating Fire Suppression Tube Automatic Fire Extinguishing Device for

  1. MOQ: 5 set
  2. Price: USD265-296/set
  3. Get Latest Price
Payment Terms T/T, L/C
Supply Ability 30000set/month
Delivery Time 15-20days
Packaging Details Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
Type Fm200 direct type/ indirect type
Capacity of agent 2kg, 3kg, 4kg, 6kg, 9kg, 12kg
Working pressure 2.5Mpa
Max working pressure 4.2Mpa
Working temperature 0-50℃
Density of unit volume 0.7kg/m3
Length of detecting tube 5m-25m
Length of releasing tube 0.5m-1.5m
Brand Name XINGJIN
Model Number WZ-Q/T-QZ3-XJ60
Certification GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1
Place of Origin Guangzhou,China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C Supply Ability 30000set/month
Delivery Time 15-20days Packaging Details Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
Type Fm200 direct type/ indirect type Capacity of agent 2kg, 3kg, 4kg, 6kg, 9kg, 12kg
Working pressure 2.5Mpa Max working pressure 4.2Mpa
Working temperature 0-50℃ Density of unit volume 0.7kg/m3
Length of detecting tube 5m-25m Length of releasing tube 0.5m-1.5m
Brand Name XINGJIN Model Number WZ-Q/T-QZ3-XJ60
Certification GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1 Place of Origin Guangzhou,China
High Light FM200 fire suppression tube ,self-actuating cable tunnel protection ,rack fire suppression unit
Temperature Self-Starting Fire Extinguishing Device

Temperature-sensing, self-actuating fire extinguishing devices are an advanced fire suppression solution developed both domestically and internationally. They are fixed, non-electric, and self-actuating, requiring no power source or traditional fire detection and alarm equipment. The entire system consists solely of a fire extinguishing agent storage cylinder and a flexible fire detection tube. The fire detection tube integrates fire detection, device activation, and fire extinguishing agent release. These flexible tubes can be conveniently positioned closest to any potential ignition source. In the event of a fire, the tube ruptures due to heat, instantly releasing the extinguishing agent for targeted suppression.

Product Types

Automatic fire extinguishing systems with fire detector tubes can be divided into direct and indirect fire detector tube systems based on their system structure.

1. Direct Temperature-Sensitive Self-Activating Fire Extinguishing System
Components

The system primarily consists of a container containing fire extinguishing agent, a container valve, a pressurized fire detector tube that releases the agent and has fire detection capabilities, a pressure gauge, a check valve, a pressure switch, an alarm, and a dedicated connector for the fire detector tube.

The fire detector tube is a high-tech non-metallic composite product. It combines long-term leak resistance, flexibility, and effective temperature sensitivity. After pressurization, it ruptures within a certain temperature range to release the extinguishing agent or transmit a fire signal.

Working Principle

The fire detector tube is connected to the fire extinguishing agent container via a container valve and is positioned above the most likely fire source to detect it. When a fire occurs, the fire detector tube softens and ruptures at the highest point of heat exposure. The pressure drop in the tube activates the container valve, releasing the fire extinguishing agent through the rupture hole in the fire detector tube to extinguish the fire. At the same time, an alarm bell sounds, alerting the user that the system has been activated. The user must then verify the extinguishing process, repair the system, and refill the extinguishing agent.

Diagram of direct temperature-sensitive self-activating fire extinguishing system showing container, valve, and fire detector tube layout
2. Indirect Temperature-Sensing Self-Activating Fire Extinguishing Device
Components

This device primarily consists of a container containing the extinguishing agent, a container valve, a pressurized fire detection tube, a release tube, a nozzle, a pressure gauge, a check valve, a pressure switch, an alarm bell, and a dedicated connector for the fire detection tube.

Operating Principle

The fire detection tube is connected to the extinguishing agent container via the container valve and positioned above the most likely fire source to detect it. Upon encountering a fire, the fire detection tube softens and ruptures at the highest point of heat exposure. The pressure drop in the tube activates the container valve, releasing the extinguishing agent through the release tube to the nozzle, extinguishing the fire. At the same time, an alarm bell sounds, alerting the user that the system has been activated. The user must then verify the extinguishing process, repair the system, and refill the extinguishing agent.

Diagram of indirect temperature-sensing self-activating fire extinguishing device showing container, release tube, and nozzle arrangement
System Application Scope

The temperature-sensing automatic fire extinguishing system solves the long-standing fire prevention problem in fire-prone spaces such as electrical equipment, control boxes, and distribution boards—a challenge that has long affected the fire protection industry. Currently, this system has been widely used in power plants, telecommunications, broadcasting, petrochemical, and railway systems in China, accumulating a wealth of successful experience.

1. Suitable Firefighting Locations
  • Microwave rooms, decimeter wave rooms, meter wave rooms, substations, and uninterruptible power supply rooms within radio and television transmission towers
  • Programmable switching rooms, control rooms, and signaling transfer point rooms within communication systems
  • Control rooms, electronic equipment rooms, computer rooms, relay rooms, and substations in power plants
  • Areas where cables cross, are densely packed, and where intermediate joints are located
  • Substation cabinets, elevator control cabinets, and cable trays with trough boxes or bridges
  • Other locations with relatively enclosed enclosures for special or critical equipment
2. Applicable Fire Types

Heptafluoropropane-filled automatic fire extinguishing devices with fire-detecting tubes can be used to extinguish the following fires:

  • Fires involving combustible gases where the gas source can be shut off before extinguishing the fire
  • Fires involving Class A, B, or C liquids or meltable solids such as paraffin and asphalt
  • Fires involving solid surfaces and deep-seated fires involving some solid materials such as cotton, fabric, and paper
  • Electrical fires
3. Prohibited Fire Types

Heptafluoropropane-filled automatic fire extinguishing devices with fire-detecting tubes must not be used to extinguish the following fires:

  • Fires involving chemicals containing oxidants, such as nitrocellulose and gunpowder
  • Fires involving reactive metals such as potassium, sodium, magnesium, titanium, and zirconium
  • Fires involving metal hydrides such as potassium hydride and sodium hydride
Packaging and Shipping
Packaging

The Inert Gas Fire Suppression System will be carefully packaged to ensure safe delivery and handling. Packaging materials include:

  • Heavy-duty cardboard box
  • Bubble wrap
  • Protective foam inserts
  • Instruction manual
Shipping

We offer worldwide shipping for our Inert Gas Fire Suppression System. All shipments are sent using a reliable and trusted courier service to ensure timely and secure delivery. Customers will receive a tracking number via email once their order has been shipped.

Special Handling Instructions

If there are any special handling instructions for your shipment, please contact us at least 24 hours before your order is shipped. We will do our best to accommodate your request.

Why Choose Us
Company advantages and credentials for the FM200 fire suppression tube system

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2010

  • Total Annual:

    600000-1200000

  • Employee Number:

    100~300

  • Ecer Certification:

    Verified Supplier

About Us:   Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro... About Us:   Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou Xingjin Fire Equipment Co.,Ltd.
  • Room 703&704, N0.3 Building, NO.8 Lianyun Erheng Road, Shiqi Town, Panyu District, Guangzhou, China
  • https://www.fm200-system.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement