China factories

Chat Now Send Email
China factory - Guangzhou Xingjin Fire Equipment Co.,Ltd.

Guangzhou Xingjin Fire Equipment Co.,Ltd.

  • China,Guangzhou ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Self-Actuating FM200 Fire Suppression Tube / Automatic Solution For Cable Tunnel
China Self-Actuating FM200 Fire Suppression Tube / Automatic Solution For Cable Tunnel

  1. China Self-Actuating FM200 Fire Suppression Tube / Automatic Solution For Cable Tunnel
  2. China Self-Actuating FM200 Fire Suppression Tube / Automatic Solution For Cable Tunnel
  3. China Self-Actuating FM200 Fire Suppression Tube / Automatic Solution For Cable Tunnel
  4. China Self-Actuating FM200 Fire Suppression Tube / Automatic Solution For Cable Tunnel
  5. China Self-Actuating FM200 Fire Suppression Tube / Automatic Solution For Cable Tunnel

Self-Actuating FM200 Fire Suppression Tube / Automatic Solution For Cable Tunnel

  1. MOQ: 5 set
  2. Price: USD265-296/set
  3. Get Latest Price
Payment Terms T/T, L/C
Supply Ability 30000set/month
Delivery Time 15-20days
Packaging Details Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
Type Fm200 direct type/ indirect type
Capacity of agent 2kg, 3kg, 4kg, 6kg, 9kg, 12kg
Working pressure 2.5Mpa
Max working pressure 4.2Mpa
Working temperature 0-50℃
Density of unit volume 0.7kg/m3
Length of detecting tube 5m-25m
Length of releasing tube 0.5m-1.5m
Brand Name XINGJIN
Model Number WZ-Q/T-QZ3-XJ60
Certification GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1
Place of Origin Guangzhou,China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C Supply Ability 30000set/month
Delivery Time 15-20days Packaging Details Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
Type Fm200 direct type/ indirect type Capacity of agent 2kg, 3kg, 4kg, 6kg, 9kg, 12kg
Working pressure 2.5Mpa Max working pressure 4.2Mpa
Working temperature 0-50℃ Density of unit volume 0.7kg/m3
Length of detecting tube 5m-25m Length of releasing tube 0.5m-1.5m
Brand Name XINGJIN Model Number WZ-Q/T-QZ3-XJ60
Certification GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1 Place of Origin Guangzhou,China

Temperature self starting fire extinguishing device


Product Introduction:
  Temperature-sensing, self-actuating fire extinguishing devices are a type of advanced fire extinguishing device that has recently been developed both domestically and internationally. They are fixed, non-electric, and self-actuating. They require no power source or traditional fire detection and alarm equipment. The entire system consists solely of a fire extinguishing agent storage cylinder and a flexible fire detection tube. The fire detection tube integrates fire detection, device activation, and fire extinguishing agent release. These flexible fire detection tubes can be conveniently positioned closest to any potential ignition source. In the event of a fire, the fire detection tubes rupture due to heat, instantly releasing the fire extinguishing agent for targeted extinguishing.

 

Product Type:
  Automatic fire extinguishing systems with fire detector tubes can be divided into direct and indirect fire detector tubes based on their system structure.
1. Direct Temperature-Sensitive Self-Activating Fire Extinguishing System



1) Components
  It primarily consists of a container containing fire extinguishing agent, a container valve, a pressurized fire detector tube that releases the agent and has fire detection capabilities, a pressure gauge, a check valve, a pressure switch, an alarm, and a dedicated connector for the fire detector tube.
  The fire detector tube is a high-tech non-metallic composite product. It combines long-term leak resistance, flexibility, and effective temperature sensitivity. After pressurization, it explodes within a certain temperature range to release the extinguishing agent or transmit a fire signal.
2) Working Principle
  The fire detector tube is connected to the fire extinguishing agent container via a container valve. It is positioned above the most likely fire source to detect the fire source. When a fire occurs, the fire detector tube softens and explodes at the highest point of heat exposure. The pressure drop in the fire detector tube activates the container valve, releasing the fire extinguishing agent through the explosion hole in the fire detector tube, extinguishing the fire. At the same time, an alarm bell sounds, alerting the user that the fire extinguishing system has been activated. The user needs to verify the fire extinguishing process, repair the system, and refill the extinguishing agent.
2. Indirect Temperature-Sensing Self-Activating Fire Extinguishing Device





1) Components
  This device primarily consists of a container containing the extinguishing agent, a container valve, a pressurized fire detection tube, a release tube, a nozzle, a pressure gauge, a check valve, a pressure switch, an alarm bell, and a dedicated connector for the fire detection tube.
2) Operating Principle
  The fire detection tube is connected to the extinguishing agent container via the container valve and positioned above the most likely fire source to detect the fire source. Upon encountering a fire, the fire detection tube softens and ruptures at the highest point of heat exposure. The pressure drop in the fire detection tube activates the container valve, releasing the extinguishing agent through the release tube to the nozzle, extinguishing the fire. At the same time, an alarm bell sounds, alerting the user that the fire extinguishing system has been activated. The user needs to verify the fire extinguishing process, repair the system, and refill the extinguishing agent.


 


 

System Application Scope:

  The temperature-sensing automatic fire extinguishing system solves the long-standing fire prevention problem in fire-prone spaces such as electrical equipment, control boxes, and distribution boards, a problem that has plagued the fire protection industry. Currently, this system has been widely used in power plants, telecommunications, broadcasting, petrochemical, and railway systems in China, accumulating a wealth of successful experience.

  1. Suitable for firefighting in the following locations:

Microwave rooms, decimeter wave rooms, meter wave rooms, substations, and uninterruptible power supply rooms within radio and television transmission towers; programmable switching rooms, control rooms, and signaling transfer point rooms within communication systems; control rooms, electronic equipment rooms, computer rooms, relay rooms, and substations in power plants; areas where cables cross, are densely packed, and where intermediate joints are located; substation cabinets, elevator control cabinets, and cable trays with trough boxes or bridges; and other locations with relatively enclosed enclosures for special or critical equipment.

  2. Applicable Fire Types
  2.1 Heptafluoropropane-filled automatic fire extinguishing devices with fire-detecting tubes can be used to extinguish the following fires:
  Fires involving combustible gases where the gas source can be shut off before extinguishing the fire;
  Fires involving Class A, B, or C liquids or meltable solids such as paraffin and asphalt;
   Fires involving solid surfaces and deep-seated fires involving some solid materials such as cotton, fabric, and paper;
   Electrical fires.
  2.3 Heptafluoropropane-filled automatic fire extinguishing devices with fire-detecting tubes must not be used to extinguish the following fires:
  Fires involving chemicals containing oxidants, such as nitrocellulose and gunpowder;
   Fires involving reactive metals such as potassium, sodium, magnesium, titanium, and zirconium;
  Fires involving metal hydrides such as potassium hydride and sodium hydride.

 

Packaging and Shipping for Inert Gas Fire Suppression System
Packaging:
The Inert Gas Fire Suppression System will be carefully packaged to ensure safe delivery and handling. The packaging will consist of the following materials:Heavy-duty cardboard box,Bubble wrap,Protective foam inserts,Instruction manual
Shipping:
We offer worldwide shipping for our Inert Gas Fire Suppression System. The following shipping options are available:
All shipments will be sent using a reliable and trusted courier service to ensure timely and secure delivery.Customers will receive a tracking number via email once their order has been shipped.

Special Handling Instructions:
If there are any special handling instructions for your shipment, please contact us at least 24 hours before your order is shipped. We will do our best to accommodate your request.




Why Choose Us


Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2010

  • Total Annual:

    >50000

  • Employee Number:

    >100

  • Ecer Certification:

    Verified Supplier

GUANGZHOU XINGJIN FIRE EQUIPMENT CO., LTD. is a professional manufacturer of making and installing fm200 fire suppression system and other fire fighting equipments.  Guangzhou Xingjin Fire Equipment Co., Ltd., surrounded by convenient transportation and beautiful environment, is located... GUANGZHOU XINGJIN FIRE EQUIPMENT CO., LTD. is a professional manufacturer of making and installing fm200 fire suppression system and other fire fighting equipments.  Guangzhou Xingjin Fire Equipment Co., Ltd., surrounded by convenient transportation and beautiful environment, is located...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou Xingjin Fire Equipment Co.,Ltd.
  • Room 703&704, N0.3 Building, NO.8 Lianyun Erheng Road, Shiqi Town, Panyu District, Guangzhou, China
  • https://www.fm200-system.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement