| Payment Terms | T/T, L/C |
| Supply Ability | 30000set/month |
| Delivery Time | 15-20days |
| Packaging Details | Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper |
| Cylinder Volume | 90Ltr, 120Ltr, 150Ltr, 180Ltr, 245Ltr |
| Filling Capacity of Gas | 112.5kg, 150kg, 187.5kg, 225kg, 306.25kg |
| Max Working Pressure | 8Mpa, 5.3Mpa |
| Max protected area | Single zone: 800m2 |
| Max protected volume | Single zone: 3600m3 |
| Spraying Time | ≤10s |
| Agent Filling Density | ≤1250kg/m3 |
| Power | DC24V/1A |
| Pressure of Adding Pressure Cylinder | 13.5Mpa |
| Pressure of Driving Device | 6.0Mpa(20℃) |
| Condition of Reserving Room for Container | temperature: 0~50℃ |
| Brand Name | XINGJIN |
| Model Number | QMQ5.6/90W-XJ, QMQ5.6/120W-XJ QMQ5.6/150W-XJ, QMQ5.6/180W-XJ QMQ4.2/245W-XJ |
| Certification | GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1 |
| Place of Origin | Guangzhou,China |
View Detail Information
Explore similar products
2.5Mpa 180L Hfc-227ea Fm200 Cabinet Fire Extinguishing System With High Quality
Cabinet FM200(HFC227ea) Fire Suppression System Low Maintenance High Safety With
Xingjin red FM200 Cabinet System Factory Direct Quality Assurance Best Price
Certified FM200 Cabinet System Automatic Or Manual Start Fire Extinguisher Class
Product Specification
| Payment Terms | T/T, L/C | Supply Ability | 30000set/month |
| Delivery Time | 15-20days | Packaging Details | Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper |
| Cylinder Volume | 90Ltr, 120Ltr, 150Ltr, 180Ltr, 245Ltr | Filling Capacity of Gas | 112.5kg, 150kg, 187.5kg, 225kg, 306.25kg |
| Max Working Pressure | 8Mpa, 5.3Mpa | Max protected area | Single zone: 800m2 |
| Max protected volume | Single zone: 3600m3 | Spraying Time | ≤10s |
| Agent Filling Density | ≤1250kg/m3 | Power | DC24V/1A |
| Pressure of Adding Pressure Cylinder | 13.5Mpa | Pressure of Driving Device | 6.0Mpa(20℃) |
| Condition of Reserving Room for Container | temperature: 0~50℃ | Brand Name | XINGJIN |
| Model Number | QMQ5.6/90W-XJ, QMQ5.6/120W-XJ QMQ5.6/150W-XJ, QMQ5.6/180W-XJ QMQ4.2/245W-XJ | Certification | GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1 |
| Place of Origin | Guangzhou,China | ||
| High Light | FM200 fire suppression system ,high pressure FM200 storage ,inert gas data center suppression | ||
Piston Flow Type of FM200 Fire Suppression System
Description:
Heptafluoropropane (HFC-227ea/FM200) is a clean gas fire extinguishing agent that primarily extinguishes fires chemically, while also providing physical extinguishing properties. It is colorless, odorless, low-toxic, non-conductive, and non-contaminating to the objects being protected.
Our company's externally stored pressurized heptafluoropropane (HFC-227ea) fire extinguishing system (compliant with standard Q/HFRD 001-2046) incorporates advanced domestic and international gas fire extinguishing research technologies, offering high strength, safety, reliability, and easy operation and maintenance. It features both automatic and manual activation. Relying on an external drive, it delivers the agent over a greater distance within the effective fire extinguishing time.
This automatic fire extinguishing system primarily consists of a fire extinguishing agent storage cylinder, container valve, power drive cylinder assembly, drive gas cylinder assembly, selector valve, liquid check valve, gas check valve, safety valve, signal feedback device, cylinder frame, nozzle, high-pressure hose, pressure reducing device, level gauge, low-leakage, high-sealing valve, and piping system, allowing it to be assembled into a standalone unit. It can be used in various forms, such as combined distribution systems, to provide single-zone and multi-zone fire protection. It is widely used in computer rooms, power distribution rooms, telecommunications centers, libraries, archives, treasure collection rooms, underground projects, and other locations for Class A surface fires, Class B and C fires, and electrical equipment fires. However, it is not suitable for fires involving active substances such as potassium, sodium, magnesium, and uranium, as well as metal chlorides and digestive fiber.
Fire extinguishing principle of fire extinguishing agent:
HFC-227ea fire extinguishing agent extinguishes fire mainly due to its fast heat removal speed. Its fire extinguishing principle is composed of the following three parts:
1) cooling the protected area; 2) dispersion of fire extinguishing agent; 3) consumption of oxygen.
(1) HFC-227ea fire extinguishing agent is sprayed into the protected area in liquid form. When spraying out of the nozzle, the liquid fire extinguishing agent can quickly turn into gas and absorb the heat of the master. It reduces the temperature of the protected area and the surrounding of the flame.
(2) HFC-227ea fire extinguishing agent is composed of large molecules. When extinguishing a fire, some of the bonds in the molecules are broken and heat is absorbed.
(3) The spraying of fire extinguishing agent and the presence of flame in the protected area reduce the concentration of oxygen, thereby reducing the combustion rate.
Working principle of independent unit system
The working principle of this system is relatively simple. Only when a fire occurs, the alarm control panel issues a command. After a delay, the solenoid valve opens and releases the nitrogen in the driving gas bottle group. The starting gas passes through the starting pipeline, opens the power drive bottle group to work, and the gas in the power drive bottle group pushes the fire extinguishing agent in the fire extinguishing agent storage bottle. The fire extinguishing agent passes through the connecting hose and the liquid flow one-way valve into the collecting pipe, the delivery pipe network, and the nozzle to spray the fire extinguishing agent into the protected area to put out the fire.
| Multiple cylinders for one zone | Multiple cylinders for multiple zones |
Applications:
It is widely used in computer rooms, power distribution rooms, telecommunications centers, libraries, archives, treasure chest and underground engineering for the class A, B, C fire and electrical equipment fire. But it is not applicable to potassium, sodium, magnesium, uranium and active metal chloride and digestive fiber fire places.
Working Principles and Operations of Various Activation Modes:
Automatic Control—Set the control mode selector on the fire extinguishing controller to "Automatic." When a fire detector in a protected area signals a fire, the alarm control panel automatically sounds an audible and visual alarm. Simultaneously, a linkage command is issued to close interlocking devices (such as ventilation and air conditioning systems, fire shutters, etc.). After a pre-set 30-second delay, a signal is output to activate the fire extinguishing system, causing the electromagnetically activated gas cylinders in the corresponding protected area to open. The release of priming gas opens the corresponding selector valves and fire extinguishing agent storage cylinders, releasing the fire extinguishing agent and extinguishing the fire.
Manual Control—Set the control mode selector on the fire extinguishing controller to "Manual." When a fire detector in a protected area signals a fire, the alarm control panel automatically sounds an audible and visual alarm. At the same time, a linkage command is issued to shut down related equipment (such as ventilation and air conditioning, fire shutter doors, etc.), but no signal to start the fire extinguishing system is output. At this time, the on-duty personnel need to confirm the fire and press the manual control button on the fire extinguishing controller or the emergency start button outside the protection zone to open the driving gas cylinder group and the fire extinguishing agent storage bottle according to the automatic procedure, release the fire extinguishing agent, and implement fire extinguishing.
Packaging and Shipping for Inert Gas Fire Suppression System
Packaging:
The Inert Gas Fire Suppression System will be carefully packaged to ensure safe delivery and handling. The packaging will consist of the following materials:Heavy-duty cardboard box,Bubble wrap,Protective foam inserts,Instruction manual
Shipping:
We offer worldwide shipping for our Inert Gas Fire Suppression System. The following shipping options are available:
All shipments will be sent using a reliable and trusted courier service to ensure timely and secure delivery.Customers will receive a tracking number via email once their order has been shipped.
Special Handling Instructions:
If there are any special handling instructions for your shipment, please contact us at least 24 hours before your order is shipped. We will do our best to accommodate your request.
Why Choose Us
![]()
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
>50000
Employee Number:
>100
Ecer Certification:
Verified Supplier
GUANGZHOU XINGJIN FIRE EQUIPMENT CO., LTD. is a professional manufacturer of making and installing fm200 fire suppression system and other fire fighting equipments. Guangzhou Xingjin Fire Equipment Co., Ltd., surrounded by convenient transportation and beautiful environment, is located... GUANGZHOU XINGJIN FIRE EQUIPMENT CO., LTD. is a professional manufacturer of making and installing fm200 fire suppression system and other fire fighting equipments. Guangzhou Xingjin Fire Equipment Co., Ltd., surrounded by convenient transportation and beautiful environment, is located...