| Payment Terms | T/T,L/C |
| Supply Ability | 30000set/month |
| Delivery Time | 15-20days |
| Packaging Details | Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper |
| Density | 1.05g/cm3 ±0.1g/cm3 |
| Melting point temperature | 170℃±10℃ |
| Nominal working pressure | 5.7Mpa |
| Maximum working pressure | 12.1Mpa |
| Operating temperature range | (0~49)℃ |
| Maximum length of fire detection tube | 25m |
| Maximum loading factor | 0.6kg/L |
| Brand Name | XINGJIN |
| Model Number | WZ-Q/T-EJ45-XJ60 |
| Certification | GSG\TUV\GB6653-2008 |
| Place of Origin | Guangzhou,China |
View Detail Information
Explore similar products
3Kg Fm200 Fire Extinguisher Tube With GB25972-2010 Standard
42kg Co2 Fire Extinguishing Devices Fire Detection Tube Of Indirect Type: 0-49℃,
Co2 Direct Type Fire Extinguisher Tube 12.1Mpa Max Working Pressure
Automatic Carbon Dioxide Fire Extinguisher
Product Specification
| Payment Terms | T/T,L/C | Supply Ability | 30000set/month |
| Delivery Time | 15-20days | Packaging Details | Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper |
| Density | 1.05g/cm3 ±0.1g/cm3 | Melting point temperature | 170℃±10℃ |
| Nominal working pressure | 5.7Mpa | Maximum working pressure | 12.1Mpa |
| Operating temperature range | (0~49)℃ | Maximum length of fire detection tube | 25m |
| Maximum loading factor | 0.6kg/L | Brand Name | XINGJIN |
| Model Number | WZ-Q/T-EJ45-XJ60 | Certification | GSG\TUV\GB6653-2008 |
| Place of Origin | Guangzhou,China | ||
| High Light | CO2 automatic fire extinguishing device ,indirect temperature sensing fire tube ,fire detection tube with CO2 | ||
CO2 Indirect Fire Trace Tube Fire Suppression System is an advanced automatic fire suppression solution designed to detect and extinguish fires at the earliest stage. The system integrates fire detection, system activation, and fire extinguishing into a single detection tube without requiring electricity, sensors, or complex control panels.
The CO2 fire detection tube is installed close to potential fire sources. When the temperature reaches approximately 170°C, the tube ruptures at the hottest point, causing a pressure drop that activates the cylinder valve. The CO2 extinguishing agent is then released through the discharge pipe and nozzle, delivering rapid point-to-point fire suppression.
This CO2 indirect fire trace tube system is widely used to protect electrical equipment, cabinets, power distribution panels, communication equipment, and other enclosed or semi-enclosed spaces where early fire detection is critical.![]()
The fire detection tube functions as both a fire detector and activation device, automatically releasing the extinguishing agent once a fire occurs.
The system operates mechanically without electrical power, eliminating the risk of electrical failure and reducing installation complexity.
The tube bursts directly at the hottest point, allowing the system to suppress fire at the source within seconds, preventing fire spread.
With only a CO2 cylinder, fire detection tube, and discharge nozzle, the system is compact and easy to install even inside small equipment enclosures.
Compared with traditional gas fire suppression systems, the fire trace tube system reduces agent consumption by up to 80%, significantly lowering installation and maintenance costs.
Because the system does not rely on electronic components, it is resistant to vibration, dust, humidity, and electromagnetic interference.
The CO2 indirect fire detection tube system is ideal for protecting small enclosed spaces or critical equipment where traditional fire suppression systems are difficult to install.
Typical applications include:
Electrical cabinets and control panels
Power distribution cabinets
UPS battery cabinets
Telecommunication cabinets
Server racks and IT equipment
Cable trays and cable tunnels
Industrial machinery enclosures
Power plants and substations
Broadcasting and communication facilities
These environments often contain electrical equipment where rapid fire detection and localized suppression are essential to prevent major damage.
CO2间接式说明书
The CO2 indirect fire trace tube system mainly consists of the following components:
CO2 extinguishing agent cylinder
Container valve
Fire detection tube (pressurized sensing tube)
Discharge pipe
Nozzle
Pressure gauge
Check valve
Pressure switch
Alarm bell
Special tube fittings
When the detection tube ruptures due to heat, the pressure drop activates the container valve, allowing the CO2 extinguishing agent to discharge through the nozzle and suppress the fire immediately.
CO2间接式说明书
| Parameter | Specification |
|---|---|
| Fire Suppression Agent | CO2 |
| System Type | Indirect Fire Trace Tube |
| Working Pressure | 5.7 MPa |
| Maximum Working Pressure | 12.1 MPa |
| Operating Temperature | 0 – 49°C |
| Minimum Agent Density | 1.5 kg/m³ |
| Detection Tube Diameter | Ø6 mm |
| Tube Melting Temperature | 170 ±10°C |
| Maximum Detection Tube Length | 25 m |
| Maximum Discharge Pipe Length | 12 m |
The CO2 automatic fire trace tube system works through a simple but highly reliable mechanism:
The pressurized fire detection tube is installed close to potential fire hazards.
When a fire occurs, the tube softens and ruptures at the hottest point (around 170°C).
The pressure drop inside the tube triggers the container valve.
The CO2 extinguishing agent is released through the discharge pipe and nozzle.
The fire is rapidly suppressed at the ignition source.
The pressure switch activates an alarm signal to notify personnel.
This process enables fully automatic fire detection and suppression without human intervention.
CO2间接式说明书
Early fire detection directly at the ignition source
Automatic operation without electrical power
Minimal installation space required
Quick discharge and efficient fire suppression
Suitable for enclosed equipment protection
Low installation and maintenance cost
Reliable operation in harsh environments
15+ years of fire protection manufacturing experience
OEM / ODM customization available
Strict quality control and international standards
Professional technical support for system design
Fast delivery for global projects
Our CO2 fire trace tube suppression systems are widely exported and used in industrial facilities, energy infrastructure, telecommunications equipment rooms, and electrical protection applications worldwide.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
600000-1200000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro... About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro...
Get in touch with us
Leave a Message, we will call you back quickly!