Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Self-Contained FM200 Cabinet System with Automatic Activation and \u226410s Spraying","imgUrl":"https:\/\/img.chinax.com\/nimg\/bd\/09\/1a88cabc562350111d92216d05f0-200x200-1\/self_contained_fm200_cabinet_system_with_automatic_activation_and_e2_89_a410s_spraying.jpg","attrs":{"Supply Ability":"3000set\/month","Filling pressure":"2.5Mpa","Model Number":"GQQ40 GQQ70 GQQ90 GQQ100 GQQ120 GQQ150 GQQ180","Minimum Order Quantity":"5 set"}}
{"title":"2.5Mpa 180L Hfc-227ea Fm200 Cabinet Fire Extinguishing System With High Quality","imgUrl":"https:\/\/img.chinax.com\/nimg\/3c\/d4\/1e66442eb04bb2a72f1a6c2e370f-200x200-1\/2_5mpa_180l_hfc_227ea_fm200_cabinet_fire_extinguishing_system_with_high_quality.jpg","attrs":{"Brand Name":"xingjin","Certification":"CAL,CMA,CNAS,ILAC-MRA,CCC","Place of Origin":"China","Minimum Order Quantity":"1set system"}}
{"title":"Cabinet FM200 Fire Suppression System with Single Zone Management DC24V\/1.6A","imgUrl":"https:\/\/img.chinax.com\/nimg\/6d\/3c\/de01ebc5fbbb2f39c023b4799a7b-200x200-1\/cabinet_fm200_fire_suppression_system_with_single_zone_management_dc24v_2f1_6a_power_and_e2_89_a410s_spraying_time.jpg","attrs":{"Brand Name":"xingjin","Certification":"CAL,CMA,CNAS,ILAC-MRA,CCC","Place of Origin":"China","Minimum Order Quantity":"2set system"}}
{"title":"Xingjin red FM200 Cabinet System Factory Direct Quality Assurance Best Price","imgUrl":"https:\/\/img.chinax.com\/nimg\/a6\/2d\/6de6b61cf93ca079c640b07213b0-200x200-1\/xingjin_red_fm200_cabinet_system_factory_direct_quality_assurance_best_price.jpg","attrs":{"Brand Name":"Guangzhou Xingjin Fire Equipment Co.,Ltd.","Model Number":"40L\/70L\/90L\/100L\/120L\/150L","Place of Origin":"Guangzhou, Guangdong, China","Certification":"GSG\\TUV\\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1"}}
{"title":"Certified FM200 Cabinet System Automatic Or Manual Start Fire Extinguisher Class","imgUrl":"https:\/\/img.chinax.com\/nimg\/60\/50\/8b88adbbf6cc2a934cf4f0f5ea6a-200x200-1\/certified_fm200_cabinet_system_automatic_or_manual_start_fire_extinguisher_class_a_2fb_2fc_fires.jpg","attrs":{"Brand Name":"Guangzhou Xingjin Fire Equipment Co.,Ltd.","Model Number":"40L\/70L\/90L\/100L\/120L\/150L","Place of Origin":"Guangzhou, Guangdong, China","Certification":"GSG\\TUV\\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1"}}
{"title":"2.5MPa Pressure High-Performance FM200 Cabinet System For Effective Fire","imgUrl":"https:\/\/img.chinax.com\/nimg\/3d\/6a\/986040b55b35525c41bf65a6e454-200x200-1\/2_5mpa_pressure_high_performance_fm200_cabinet_system_for_effective_fire_protection.jpg","attrs":{"Brand Name":"Xingjin\/OEM","Model Number":"40L\/70L\/90L\/100L\/120L\/150L","Place of Origin":"Guangzhou, Guangdong, China","Certification":"GSG\\TUV\\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1"}}
{"title":"Enclosed Flooding FM200 Cabinet System Single Zone Easy Installation 200L","imgUrl":"https:\/\/img.chinax.com\/nimg\/09\/b3\/ec2da354b230afa818926c957e25-200x200-1\/enclosed_flooding_fm200_cabinet_system_single_zone_easy_installation_200l_capacity.jpg","attrs":{"Brand Name":"Guangzhou Xingjin Fire Equipment Co.,Ltd.","Model Number":"40L\/70L\/90L\/100L\/120L\/150L","Place of Origin":"Guangzhou, Guangdong, China","Product Name":"FM200 Cabinet System"}}
Self-Contained FM200 Cabinet Unit - Automatic Gas Suppression System Solution
Product Overview
The FM200 Cabinet Fire Suppression System (also known as a pre-engineered fire extinguishing system) is a self-contained clean agent fire protection unit that integrates the agent storage cylinder, actuation device, piping, and discharge nozzle into a compact cabinet enclosure. It requires no complex pipe network installation and no dedicated cylinder storage room, making it particularly suitable for spaces with limited room or for retrofit projects where extensive construction is not feasible.
The unit can be placed directly inside or adjacent to the protected area and integrated with a fire alarm control panel to achieve fully automatic detection, alarm, and fire suppression. When a fire occurs, the agent is discharged within 10 seconds, rapidly filling the entire protected enclosure to achieve total flooding fire suppression.
Key Features
Compact Integrated Design - Saves Space: The system is fully assembled and tested before leaving the factory. The cabinet has a compact footprint - with single-cabinet models starting at just 500×450×1450mm - allowing flexible placement in server rooms, electrical rooms, and other space-constrained environments without the need for a separate equipment room.
No Pipe Network - Quick Installation: Unlike traditional pipe network systems, this unit requires no complex piping installation. On-site work is limited to positioning the cabinet and connecting the control power supply, significantly reducing installation time. This makes it an ideal solution for retrofit projects and tight construction schedules.
High Efficiency - Clean and Residue-Free: Using FM200 (HFC-227ea) as the extinguishing agent, the system discharges within 10 seconds, rapidly establishing the extinguishing concentration at the early stage of a fire. As a clean agent, FM200 is non-conductive, non-corrosive, and leaves no residue - ensuring no secondary damage to sensitive electronic equipment and valuable assets.
Intelligent Integration with Multiple Activation Modes: The system can be integrated with a fire alarm control panel for automatic detection and activation. It supports three activation modes:
Automatic Activation: Discharges automatically upon double-confirmation of fire signals from detectors
Electrical Manual Activation: Manual start via emergency push button
Mechanical Emergency Activation: Direct manual operation of the cylinder valve in case of control panel failure
Flexible Configuration for Various Enclosure Sizes: Available in both single-cabinet and dual-cabinet configurations, with agent filling capacities ranging from 40kg to 300kg to meet the protection requirements of different enclosure sizes. For larger protected areas, multiple cabinets can be combined to extend protection capacity.
Fire Detection: Smoke or heat detectors installed in the protected area transmit fire signals to the fire alarm control panel.
Signal Confirmation: The control panel activates audible and visual alarms to warn personnel to evacuate, while simultaneously initiating linked equipment (e.g., shutting down HVAC systems and fire dampers).
Time Delay: The system enters a delay period (typically 0-30 seconds, adjustable), providing a safe window for personnel evacuation.
Agent Release: At the end of the delay, the control panel outputs DC24V to activate the solenoid actuator on the cylinder valve.
Total Flooding Fire Suppression: FM200 is discharged through the flexible hose and nozzle, filling the protected area and reaching the extinguishing concentration within 10 seconds for total flooding fire suppression.
Signal Feedback: After agent discharge, the pressure switch sends a feedback signal to the control panel, illuminating the discharge indicator light.
About the Extinguishing Agent
FM200 (HFC-227ea) is a colourless, odourless, low-toxicity, non-conductive, and non-corrosive clean agent. Its fire suppression mechanism combines chemical inhibition with physical cooling:
Chemical Inhibition: Decomposes at high temperatures to release fluorine-containing free radicals, which interrupt the combustion chain reaction
Physical Cooling: Absorbs a significant amount of heat during vaporisation, lowering the flame temperature
Environmental Properties:
Zero Ozone Depletion Potential (ODP)
Short atmospheric lifetime (approximately 36 years)
Safe for occupied spaces (NOAEL value of 9%)
Applications
This system is suitable for small to medium-sized protected enclosures where rapid fire suppression, equipment protection, and cleanliness are critical:
Industry / Sector
Typical Protected Areas
Data Centres & IT
Server rooms, computer rooms, data storage facilities
Telecommunications
Switching rooms, base station equipment rooms, signalling transfer points
Power Facilities
Electrical distribution rooms, transformer rooms, generator rooms, UPS battery rooms
Cultural Heritage
Library rare book collections, archives, museum exhibition halls
Industrial Facilities
Clean rooms, precision equipment rooms, control rooms, laboratories
Commercial Facilities
Bank data centres, security monitoring centres, fire control rooms
Suitable Fire Types:
Class A: Solid surface fires (paper, wood, textiles, etc.)
Class B: Liquid fires or meltable solid fires
Class C: Electrical fires (energised equipment)
Unsuitable Fire Types:
Chemical products containing oxidising agents (e.g., nitrocellulose, gunpowder)
Powder-coated steel enclosure housing all components, offering a professional appearance and high protection rating
Agent Storage Cylinder
Stores FM200 agent at 2.5MPa working pressure
Container Valve
Agent release valve assembly with solenoid actuator and manual emergency operation
Flexible Hose
Connects the container valve to the nozzle for agent delivery
Nozzle
Multi-orifice design ensuring uniform agent distribution
Pressure Gauge
Displays the storage pressure status of the cylinder
Signal Feedback Device
Sends a signal to the control panel after agent discharge
Installation Instructions
Pre-Installation Checks:
Verify that the protected enclosure volume meets design requirements
Inspect the cabinet for any transport damage
Confirm that the model and agent filling quantity match the design specifications
Installation Steps:
Cabinet Positioning: Place the cabinet at the designated location within or adjacent to the protected area, positioned securely against a wall
Cylinder Installation: Place the agent cylinder inside the cabinet and secure firmly using cylinder brackets
Hose Connection: Connect the flexible hose and ensure the nozzle is oriented correctly
Power Connection: Route the DC24V power cable into the cabinet and connect to the solenoid valve interface
Signal Connection: Connect the signal feedback device to the fire alarm control panel
System Testing: Perform a simulated activation test to verify system integration and proper operation
Installation Precautions:
The system should be installed inside or adjacent to the protected area
Ambient temperature must remain between 0°C and +50°C
Avoid direct sunlight and proximity to heat sources
Ensure sufficient clearance in front of the cabinet for operation and maintenance
The cabinet must be installed securely to prevent tipping
Maintenance and Servicing
Routine Maintenance:
Weekly: Inspect cabinet appearance, indicator lights, and pressure gauge (must remain in the green zone)
Monthly: Check all connections for looseness or leaks; clean cabinet surfaces
Quarterly: Test solenoid actuator operation (with agent cylinder isolated)
Annually: Weigh the agent cylinder - if leakage exceeds 5% of the filling quantity, refill or replace
Post-Discharge Restoration:
After the system has been discharged, professional service is required for restoration:
Replace the solenoid actuator on the container valve
Re-fill the agent cylinder according to design specifications
Re-charge the nitrogen pressurisation to the specified pressure
Perform a complete system re-commissioning
Reset the fire alarm control panel
Important Safety Notes:
⚠️ The agent cylinder contains high-pressure gas - only qualified personnel should handle it
⚠️ During discharge, the system produces a certain amount of hydrogen fluoride gas - ensure personnel have evacuated before activation
⚠️ If the pressure gauge reading falls below the green zone, contact a qualified service provider immediately
⚠️ Keep the system away from direct sunlight and high temperatures to prevent overpressure
Packaging and Shipping
Packaging:
The cabinet is packed in a wooden crate with protective cushioning material
All components are individually secured to prevent damage during transit
Product certificate, instruction manual, and installation drawings are included
Shipping Precautions:
Avoid rough handling and inversion during transport
Storage temperature range: -10°C to +50°C
Protect from rain and damp conditions
Store away from fire sources and heat
Frequently Asked Questions
Q: What is the difference between the cabinet system and a hanging unit?
A: The cabinet system offers larger agent capacity (40kg-300kg) and provides total flooding protection for small to medium-sized enclosures. Hanging units have smaller agent capacity (typically ≤30kg) and are better suited for small enclosed spaces or point-of-risk protection.
Q: How can the cabinet system be used for larger enclosures?
A: For enclosures exceeding the protection range of a single unit, dual-cabinet configurations or multiple units can be deployed. Alternatively, the cabinet-type system with pipe network can be used for multi-point discharge.
Q: Does the cabinet system require a dedicated cylinder room?
A: No. The cabinet system integrates the agent cylinder within the cabinet enclosure and can be placed directly inside or adjacent to the protected area - no separate cylinder room is required.
Q: What is the recovery process after system discharge?
A: After discharge, a qualified service provider must replace the actuation components, re-fill the agent cylinder and nitrogen, and perform a full system re-commissioning before the system can be returned to service.
Q: How can I check for agent leakage?
A: The pressure gauge provides an initial indication - the reading should remain within the green zone. Annual weighing of the cylinder provides accurate leakage data.
Why Choose Guangzhou Xingjin Fire Equipment?
Factory Direct Supply: Over 15 years of manufacturing experience, offering competitive pricing and stable supply
Quality Assurance: Products manufactured in strict compliance with GB16670-2006 and other national standards
Export Experience: Products exported to the Middle East, Southeast Asia, and other global markets
Technical Support: Comprehensive technical consultation services from system selection and design to installation
After-Sales Service: Prompt response to customer needs with professional technical support and maintenance services
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
600000-1200000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
About Us:
Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro... About Us:
Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro...