China Fire Alarm Emergency Enable Disable Control Button
China Fire Alarm Emergency Enable Disable Control Button

  1. China Fire Alarm Emergency Enable Disable Control Button
  2. China Fire Alarm Emergency Enable Disable Control Button
  3. China Fire Alarm Emergency Enable Disable Control Button
  4. China Fire Alarm Emergency Enable Disable Control Button
  5. China Fire Alarm Emergency Enable Disable Control Button

Fire Alarm Emergency Enable Disable Control Button

  1. MOQ: 100 set system
  2. Price: USD3-4/pc
  3. Get Latest Price
Delivery Time 15-20days
Bus Voltage DC 14V ~ DC 24V
Working Ambient -10℃~50℃
Screen LED
Additionalfeatures Interconnectivity, Remote Monitoring, Voice Alerts
Payment Terms T/T,L/C
Applications School
Alarming Temperature 54℃ ~ 70℃
Supply Ability 300000 sets per month
Gift Box Size 345*274*74mm
Wireless Frequency 433MHz
Packing Size 138*118*48mm
Packaging Details Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
Max Power Consumption 0.5W
Band Material PU
Warranty 1 year
Certification CCC;GB/T 3836.1-2021;GB/T 3836.4-2021;GB 19880-2005
Place of Origin Guangzhou,China
Model Number J-SAP-JBF4121A
Brand Name XINGJIN

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Delivery Time 15-20days Bus Voltage DC 14V ~ DC 24V
Working Ambient -10℃~50℃ Screen LED
Additionalfeatures Interconnectivity, Remote Monitoring, Voice Alerts Payment Terms T/T,L/C
Applications School Alarming Temperature 54℃ ~ 70℃
Supply Ability 300000 sets per month Gift Box Size 345*274*74mm
Wireless Frequency 433MHz Packing Size 138*118*48mm
Packaging Details Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper Max Power Consumption 0.5W
Band Material PU Warranty 1 year
Certification CCC;GB/T 3836.1-2021;GB/T 3836.4-2021;GB 19880-2005 Place of Origin Guangzhou,China
Model Number J-SAP-JBF4121A Brand Name XINGJIN

Products Description

  In automatic operation mode, upon receiving fire signals from detectors, the control panel activates audible and visual alarms, starts exhaust fans, disconnects non‑essential power supplies, and initiates elevator recall. Manual call points provide a secondary activation method for personnel who identify a fire situation. In gas-protected zones, two independent detectors must be activated simultaneously before the pre‑discharge timer starts. Once the delay elapses, the extinguishing agent is released, and the discharge indicators illuminate to prevent entry. This integrated sequence ensures rapid fire detection and safe occupant evacuation.


1. Detection Layer (Sensors)

The detection layer forms the sensing front‑end of the fire alarm system. It includes smoke detectors, heat detectors, and combined smoke‑heat detectors.

  • Smoke detectors monitor airborne particulates and are recommended for offices, hotels, and similar indoor spaces.

  • Heat detectors respond to temperature increases and are suitable for kitchens, garages, and boiler rooms.

  • Combined detectors utilise both smoke and heat sensing to reduce false alarms, making them ideal for hospitals and high‑value commercial premises.

  • Beam‑type smoke detectors are designed for large open areas such as warehouses and stadiums.

  • Flame detectors are recommended for high‑risk locations such as fuel depots and petrochemical facilities.

2. Input Layer (Manual and Monitoring Equipment)

This layer enables human intervention and integration with external monitoring devices. It comprises manual call points, input modules, short‑circuit isolators, and fire telephone sockets.

  • Manual call points are installed near exits and stairwells, allowing occupants to manually trigger an alarm.

  • Input modules receive signals from external equipment, including water flow switches and pressure switches.

  • Short‑circuit isolators automatically disconnect faulty sections of the circuit, protecting the system from widespread failure.

  • Fire telephone sockets provide direct voice communication between firefighters and the control centre during emergencies.

3. Control Layer (System Intelligence)

The control layer functions as the central intelligence of the fire alarm system. Its primary components are the fire alarm control panel and the gas extinguishing control panel.

  • The fire alarm control panel processes signals from all detectors and modules, determines alarm conditions, and coordinates activation of downstream equipment.

  • The gas extinguishing control panel is specifically configured for FM200, IG541, and CO₂ systems. It supports programmable start‑up delays, manual/automatic mode selection, and pressure feedback monitoring.

  • Additional control devices include repeater panels for floor‑by‑floor alarm indication and fire broadcast hosts for delivering clear evacuation announcements.

4. Execution Layer (Alarm and Actuation Equipment)

The execution layer carries out commands issued by the control panel. It includes alarm indicating appliances, output modules, fire alarm bells, and gas discharge indicators.

  • Alarm indicating appliances produce high‑intensity audible and visual signals to alert occupants for evacuation.

  • Output modules interface with building systems such as exhaust fans, fire dampers, power cut‑off relays, and elevator recall controllers.

  • Fire alarm bells offer a cost‑effective notification solution for conventional system installations.

  • Gas discharge indicators are installed at the entrances of protected areas. They illuminate prior to and during agent release to warn personnel against entry.


Product Advantages

J‑SAP‑M‑A62E – Addressable Manual Call Point

  • Certified to GB 19880

  • Simple and reliable addressing via portable programming tool

  • Stable communication with high noise immunity

  • Resettable operating element for repeated use

J‑SAP‑M‑A62KE – Conventional Manual Call Point

  • Certified to GB 19880

  • Integrated two‑wire fire telephone socket

  • Passive output contacts enable external device control via interposing relay

  • Resettable press button mechanism

J‑SAP‑M‑A62E‑Ex – Addressable Intrinsically Safe Manual Call Point

  • Certified to GB 19880, GB/T 3836.1 and GB/T 3836.4

  • Intrinsic safety explosion‑proof design

  • Fully electronic addressing with on‑site reprogramming via encoder

  • Direct control capability for external equipment

  • Resettable operating element


Products Parameters

Specifications J-SAP-M-A62E J-SAP-M-A62KE J-SAP-M-A62E-Ex
Operating Voltage Loop 24V DC 24V Loop 24V
Operating Current Quiescent current: <300µA
Alarm current: <2mA
Quiescent current: <0µA
Alarm current: <25mA
Quiescent current: <300µA
Alarm current: <1mA
Dimension (with base) 90×90×43mm (W×H×D) 90×90×43mm (W×H×D) 100×90×43mm (W×H×D)
Explosion-proof Sign - - Ex ib IIC T6 Gb
Operating Environment Operating Temperature: -10°C to 55°C
Relative Humidity: ≤ 95% (Non-condensing at 40°C ±2°C)



Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2010

  • Total Annual:

    600000-1200000

  • Employee Number:

    100~300

  • Ecer Certification:

    Verified Supplier

About Us:   Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro... About Us:   Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou Xingjin Fire Equipment Co.,Ltd.
  • Room 703&704, N0.3 Building, NO.8 Lianyun Erheng Road, Shiqi Town, Panyu District, Guangzhou, China
  • https://www.fm200-system.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement