| Delivery Time | 15-20days |
| Minimum Oeder Quantity | 1set |
| Maintenance | Monthly Testing Recommended |
| Power | Battery |
| Bus Voltage | DC 14V ~ DC 24V |
| Alarm Concentration | 0.65~15.5%FT |
| Indicated Light | Red (Alarm/Failed), Green (Running) |
| Light Intensity | 135cd |
| Installation | Wall mounting |
| Usage | Fire alarm display and alarming |
| Operatingtemperaturerange | -10°C to 50°C |
| Packaging Details | Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper |
| Nominal Diameter | 15mm, 20mm |
| Power Voltage | DC 24V |
| Payment Terms | T/T,L/C |
| Temperature | -10℃ to +55℃ |
| Working Voltage | DC19-28V |
| Supply Ability | 300000 sets per month |
| Poe | Optional |
| Model Number | J-SAP-JBF4121A |
| Brand Name | XINGJIN |
| Certification | CCC;GB/T 3836.1-2021;GB/T 3836.4-2021;GB 19880-2005 |
| Place of Origin | Guangzhou,China |
View Detail Information
Explore similar products
J-SAP-JBF4121A-Ex Explosion-proof property Manual Fire Alarm Button
Multi- Sensor Smoke And Heat Detector For Commercial Fire Alarm System
Explosion- Proof Manual Fire Alarm Button For Hazardous Area Use
Intelligent Fire Alarm Control Panel With Gas Extinguishing Integration
Product Specification
| Delivery Time | 15-20days | Minimum Oeder Quantity | 1set |
| Maintenance | Monthly Testing Recommended | Power | Battery |
| Bus Voltage | DC 14V ~ DC 24V | Alarm Concentration | 0.65~15.5%FT |
| Indicated Light | Red (Alarm/Failed), Green (Running) | Light Intensity | 135cd |
| Installation | Wall mounting | Usage | Fire alarm display and alarming |
| Operatingtemperaturerange | -10°C to 50°C | Packaging Details | Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper |
| Nominal Diameter | 15mm, 20mm | Power Voltage | DC 24V |
| Payment Terms | T/T,L/C | Temperature | -10℃ to +55℃ |
| Working Voltage | DC19-28V | Supply Ability | 300000 sets per month |
| Poe | Optional | Model Number | J-SAP-JBF4121A |
| Brand Name | XINGJIN | Certification | CCC;GB/T 3836.1-2021;GB/T 3836.4-2021;GB 19880-2005 |
| Place of Origin | Guangzhou,China |
Products Description
The J-SAP-JBF4121A-Ex is a microprocessor‑based intrinsically safe manual fire alarm button designed for use in hazardous areas requiring explosion‑proof protection. It is suitable for connection to addressable fire alarm control panels via a non‑polarised two‑bus system, offering reliable manual alarm initiation with low power consumption and extended communication range.
Product Advantages
Microprocessor‑Based DesignBuilt around a dedicated microprocessor, the device ensures stable performance and fast response. The use of SMT surface‑mount technology enhances reliability and product consistency across all units. Non‑Polarised Two‑Bus CommunicationThe unit operates on a non‑polarised two‑bus system, which eliminates the need to distinguish between positive and negative terminals during wiring. This design simplifies installation, reduces the risk of connection errors, and supports communication distances of up to 1000 metres while maintaining low current consumption. Intrinsically Safe Explosion‑Proof ConstructionThe device is of intrinsically safe type and must be used in conjunction with a certified safety barrier. It is suitable for installation in hazardous environments where explosive gases or vapours may be present. Electronic AddressingAddress assignment is carried out using a dedicated electronic encoder, enabling fast and accurate on‑site configuration. The coding method supports straightforward system commissioning and re‑addressing when required. Simple and Secure OperationTo activate an alarm, the operator presses the front panel. The button mechanism is designed for ease of use, ensuring quick manual fire reporting. After activation, the panel can only be reset using the matching special key, preventing unauthorised or accidental reset. Plug‑In Structure for Easy MaintenanceThe unit features a plug‑in mechanical design, allowing the button assembly to be easily inserted into or removed from its base. This simplifies initial installation, routine maintenance, and future replacement, reducing on‑site labour time and effort. |
Products Parameters
| Operating environmental conditions | |
|---|---|
| Operating temperature | -10 to +55°C |
| Storage temperature | -30 to +75°C |
| Relative humidity | ≤ 95% RH (40 ± 2°C) |
| Parameter | Technical Specification |
|---|---|
| Operating Voltage | DC 18-28V, modulated type provided by controller (must use safety barrier) |
| Standby Current | ≤0.3mA (24V) |
| Alarm Current | ≤1mA (24V) |
| Explosion-proof Mark | Ex ib IIC T6 Gb |
| Addressing Method | Electronic encoder addressing |
| Addressing Range | 1-200 |
| Indicator Light | Fire indicator flashes momentarily in standby mode; stays steady red when pressed and in alarm |
| Dimensions | 90mm (L) × 90mm (W) × 52mm (H) |
| Wiring System | Two-wire bus, non-polarity |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
600000-1200000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro... About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro...
Get in touch with us
Leave a Message, we will call you back quickly!