| Delivery Time | 15-20days |
| Working Voltage | DC19-28V |
| Light Intensity | 135cd |
| Payment Terms | T/T,L/C |
| Bus Voltage | DC 14V ~ DC 24V |
| Nominal Diameter | 15mm, 20mm |
| Maintenance | Monthly Testing Recommended |
| Temperature | -10℃ to +55℃ |
| Poe | Optional |
| Minimum Oeder Quantity | 1set |
| Power Voltage | DC 24V |
| Supply Ability | 300000 sets per month |
| Indicated Light | Red (Alarm/Failed), Green (Running) |
| Usage | Fire alarm display and alarming |
| Alarm Concentration | 0.65~15.5%FT |
| Installation | Wall mounting |
| Power | Battery |
| Packaging Details | Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper |
| Operatingtemperaturerange | -10°C to 50°C |
| Model Number | J-SAP-JBF4121A |
| Brand Name | XINGJIN |
| Certification | CCC;GB/T 3836.1-2021;GB/T 3836.4-2021;GB 19880-2005 |
| Place of Origin | Guangzhou,China |
View Detail Information
Explore similar products
J-SAP-JBF4121A-Ex Explosion-proof property Manual Fire Alarm Button
Multi- Sensor Smoke And Heat Detector For Commercial Fire Alarm System
Explosion- Proof Manual Fire Alarm Button For Hazardous Area Use
Intelligent Fire Alarm Control Panel With Gas Extinguishing Integration
Product Specification
| Delivery Time | 15-20days | Working Voltage | DC19-28V |
| Light Intensity | 135cd | Payment Terms | T/T,L/C |
| Bus Voltage | DC 14V ~ DC 24V | Nominal Diameter | 15mm, 20mm |
| Maintenance | Monthly Testing Recommended | Temperature | -10℃ to +55℃ |
| Poe | Optional | Minimum Oeder Quantity | 1set |
| Power Voltage | DC 24V | Supply Ability | 300000 sets per month |
| Indicated Light | Red (Alarm/Failed), Green (Running) | Usage | Fire alarm display and alarming |
| Alarm Concentration | 0.65~15.5%FT | Installation | Wall mounting |
| Power | Battery | Packaging Details | Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper |
| Operatingtemperaturerange | -10°C to 50°C | Model Number | J-SAP-JBF4121A |
| Brand Name | XINGJIN | Certification | CCC;GB/T 3836.1-2021;GB/T 3836.4-2021;GB 19880-2005 |
| Place of Origin | Guangzhou,China |
Products Description
In automatic mode, when any detector senses a fire, it immediately transmits a signal to the control panel. The control panel then activates the audible and visual alarm devices, starts the exhaust fans, disconnects non‑essential power supplies, and sends a command to recall all elevators. If a person discovers the fire, they can press a manual call point to trigger the same sequence.
For areas protected by a gas‑based fire suppression system, the release sequence begins only after two independent detectors have been activated. Once this condition is met, a pre‑determined delay timer starts. After the delay elapses, the extinguishing gas is released, and the release indicator lights illuminate to clearly warn people not to enter the protected area. All these functions work together to ensure fast fire detection and safe occupant evacuation.
1. Detection Layer (Sensors)The detection layer acts as the sensory system of the fire alarm installation. It includes smoke detectors, heat detectors, and combined smoke‑and‑heat detectors.
|
|
2. Input Layer (Manual and Monitoring Equipment)This layer enables manual initiation and external equipment monitoring. It consists of manual call points, input modules, short‑circuit isolators, and fire telephone sockets.
|
|
3. Control Layer (The “Brain” of the System)The control layer is the central intelligence of the entire fire alarm system. Its main components are the Fire Alarm Control Panel (FACP) and the Gas Suppression Control Panel.
|
|
. Execution Layer (Alarm and Action Equipment)The execution layer carries out the commands issued by the control panel. It includes alarm sounder‑strobes, output modules, fire alarm bells, and gas release indicators.
|
Product Advantages
| J-SAP-JBF4121A-Ex Manual Fire Alarm Button 1.Built-in microprocessor, stable performance. 2.Adopts SMT surface mount technology, with high reliability and good consistency.3.Uses a dual-bus system, without polarity requirements, ensuring low power consumption while enabling the transmission distance to reach up to 1000m4.Explosion-proof type is intrinsically safe, requiring a safety barrier to be connected for use.5.Electronic coding method, can be addressed through a dedicated electronic encoder6.Operation is simple. Pressing the operation panel on the panel can realize reporting fire alarm to the controller.7.The operation panel of the manual alarm button needs to be reset after being pressed. This must be done using adedicated key that matches the button. 8.The manual alarm button adopts a plug-in structure, which is easy for customers to install, construct and maintain |
Products Parameters
| Operating environmental conditions | |
|---|---|
| Operating temperature | -10 to +55°C |
| Storage temperature | -30 to +75°C |
| Relative humidity | ≤ 95% RH (40 ± 2°C) |
| Parameter | Technical Specification |
|---|---|
| Operating Voltage | DC 18-28V, modulated type provided by controller (must use safety barrier) |
| Standby Current | ≤0.3mA (24V) |
| Alarm Current | ≤1mA (24V) |
| Explosion-proof Mark | Ex ib IIC T6 Gb |
| Addressing Method | Electronic encoder addressing |
| Addressing Range | 1-200 |
| Indicator Light | Fire indicator flashes momentarily in standby mode; stays steady red when pressed and in alarm |
| Dimensions | 90mm (L) × 90mm (W) × 52mm (H) |
| Wiring System | Two-wire bus, non-polarity |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
600000-1200000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro... About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro...