| Voltage | 220 V / 380 V |
| Payment Terms | L/C,T/T |
| Filter Mesh | 2 x 1500 mesh |
| Cyclone Separator | One |
| Supply Ability | 3 sets per season |
| Packaging Details | TO BE DETERMINED |
| Motor Power | 1.5 kW / 2.2 kW |
| Delivery Time | 45 working days after downpayment |
| Weight | 200 kg |
| Overall Dimension | 1200*650*1750 mm |
| Certification | CE |
| Model Number | C516 |
| Brand Name | Xinmeiteng |
| Place of Origin | Qingdao |
View Detail Information
Explore similar products
Stirring Volume 15m³ Rebonded Foam Machine Capacity 40r/m Scraps Plastic Foam
Seat Cushion Rebonded Foam Machine Foam Rebonding Equipment For Mattress
PE EVA Foam Recycling Machine EPE Polystyrene Rebonded Equipment Triple Shot
CE Rebonded Foam Machine Rebond Foam Product Line For PU Recycling
Product Specification
| Voltage | 220 V / 380 V | Payment Terms | L/C,T/T |
| Filter Mesh | 2 x 1500 mesh | Cyclone Separator | One |
| Supply Ability | 3 sets per season | Packaging Details | TO BE DETERMINED |
| Motor Power | 1.5 kW / 2.2 kW | Delivery Time | 45 working days after downpayment |
| Weight | 200 kg | Overall Dimension | 1200*650*1750 mm |
| Certification | CE | Model Number | C516 |
| Brand Name | Xinmeiteng | Place of Origin | Qingdao |
| High Light | 1.5 kW Foam Dust Collector ,2.2 kW Dust Extraction System ,220 V 380 V Dust Collector | ||
The C516 foam dust extraction system is available with a 1.5 kW or 2.2 kW motor, on 220 V or 380 V supply. Filtration is one cyclone separator plus 2 x 1500 mesh stainless steel elements, machine weight is 200 kg and the overall dimension is 1200*650*1750 mm.
A small foam shop and a full cutting line do not need the same extractor. One hood on a single machine needs a smaller fan than three hoods on a duct run. The C516 is offered in two motor sizes and two voltages so the unit matches the installation instead of being oversized or running short.
Suits a single hood on one cutting or trimming machine.
Suits a longer duct run with two or three hoods.
Connects to single-phase or three-phase supply.
Both motor sizes use the cyclone and 2 x 1500 mesh filters.
Test at the farthest hood. A unit that pulls well at the nearest hood can still be short at the end of the duct, and that is where the dust escapes.
Suction falls with duct length and with every bend. A fan that is adequate on a one-metre connection to a single machine can be marginal at the end of a six-metre run with two elbows. That is why the C516 is offered in two motor sizes rather than one.
The 1.5 kW unit suits a single hood close to the collector. The 2.2 kW unit is the choice when the duct run is longer or when two or three hoods are open at the same time. Both use the same cyclone and the same two 1500 mesh stainless elements, so the filtration result does not change with the motor size.
Voltage is the other constraint. A small shop may only have a 220 V supply, while a production line will have 380 V three-phase. Offering both means the unit can be installed without a supply upgrade, which is often the difference between a quick installation and a project.
| Parameter | Value |
|---|---|
| Model | C516 |
| Machine type | Fireproof dust collection system |
| Fire-proof level | Level A (non-combustible) |
| Motor power | 1.5 kW / 2.2 kW |
| Voltage | 220 V / 380 V |
| Cyclone separator | One |
| Stainless steel filter | 2 x 1500 mesh |
| Weight | 200 kg |
| Overall dimension | 1200*650*1750 mm |
| Certification | CE |
| Symptom | Likely cause | Action |
|---|---|---|
| Weak suction at the hood | Filter clogged or duct joint leaking | Clean the filters and check every duct joint |
| Dust escapes from the cabinet | Door seal worn or filter seated wrong | Replace the seal and reseat the filter |
| Motor overheats | Blocked duct or too many hoods on one unit | Clear the blockage and check motor current |
| Filter tears early | Sharp debris or wrong mesh fitted | Fit the correct 1500 mesh filter and check the inlet |
| Unit vibrates | Fan imbalance or loose mounting | Balance the fan and tighten the mounts |
| Dust settles in the duct | Air velocity too low for the run | Shorten the duct run and check fan speed |
Dust collector faults usually appear as falling suction before they appear as a motor fault. Check the filter, the duct joints and the number of open hoods first, because those three account for most weak-suction complaints.
Confirm the rotation direction of the fan before running the unit. A three-phase fan running backwards moves air, but not enough to carry dust through the duct.
Keep the duct run as short and as straight as the layout allows. Every extra bend reduces the suction available at the hood, whatever the motor size.
The motor and fan need little more than a current check and a mounting check. Record the current at commissioning, then compare it on each service, because a rise usually means a blocked duct or a loaded filter.
The filters and the duct joints set the suction. Clean the stainless elements on schedule, check the door seal, and inspect the duct joints for leaks that let dust bypass the hood.
The unit ships in an export crate with the cabinet, fan and filter elements braced for transport. The crate is sized to the 1200*650*1750 mm machine envelope.
The shipment includes the duct connection sizes, the electrical requirements and a commissioning checklist, with remote support during installation.
A: 1.5 kW for a single hood close to the unit; 2.2 kW for longer duct runs or two to three hoods.
A: Yes, the unit is available in 220 V and 380 V versions.
A: Yes, one cyclone separator plus 2 x 1500 mesh stainless steel filters.
A: Test suction at the farthest hood and record the motor current at commissioning.
Tell us the dust source, number of machines on the duct run, duct length and the voltage available on site. We will confirm the motor size, filter configuration and hood layout, then quote it with the delivery schedule. Spare filters and ducting parts are available with every order.
Company Details
Business Type:
Manufacturer
Year Established:
2002
Total Annual:
1500000-3000000
Employee Number:
50~200
Ecer Certification:
Verified Supplier
XINMEITENG is located in the beautiful seaside city of Qingdao, adjacent to Jinan-Qingdao, Qingyin, Yanqing and Qinghu highways, and connected to Jiaodong International Airport and Qingdao Port Terminal, with a superior geographical location. The company has advanced processing equipment, with more... XINMEITENG is located in the beautiful seaside city of Qingdao, adjacent to Jinan-Qingdao, Qingyin, Yanqing and Qinghu highways, and connected to Jiaodong International Airport and Qingdao Port Terminal, with a superior geographical location. The company has advanced processing equipment, with more...
Get in touch with us
Leave a Message, we will call you back quickly!