Payment Terms | T/T,Western Union or Paypal |
Supply Ability | 1972pcs/month |
Delivery Time | 3~25 working days |
Packaging Details | Carton |
Usage | Measuring torque |
Type | Stationary torque transducer |
Mounting | Flange-to-flange |
Capacity | 0-100Nm(Selectable) |
Output | Analog sensor |
Brand Name | Forsentek |
Model Number | FTA |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
M8 Tension Load Cell 100kg Tension Force Sensor 1KN Force Transducer 200lb
Tension Load cell 200kg Tension Force Transducer 2KN Force Measurement 450lb
M8 Threaded Tension Load Cell 300kg Compression Force Transducer 3KN
Tension Load Cell 500kg Tension Force Sensor 5KN Force Transducer 1.1klb
Product Specification
Payment Terms | T/T,Western Union or Paypal | Supply Ability | 1972pcs/month |
Delivery Time | 3~25 working days | Packaging Details | Carton |
Usage | Measuring torque | Type | Stationary torque transducer |
Mounting | Flange-to-flange | Capacity | 0-100Nm(Selectable) |
Output | Analog sensor | Brand Name | Forsentek |
Model Number | FTA | Certification | CE |
Place of Origin | China |
Reaction Torque Transducer 2lbf*in 5 lb-in 10 lb*in 20 in-lb Torque Sensor With Display Unit
Flange-to-Flange Type Reaction Torque Sensor FTA is strain gague based with mV/V output intended for non-rotating torque measurement,torque meter FTA offers 1.77lb*in / 4.4 lbf*in / 8.8lb-in / 17.7 lbf*in / 26.5lbf-in / 44 lbf-in / 88lb*in / 177 lb-in / 265lbf*in / 442 lbf-in / 885lbf*in eleven rated capacities to choose from.0.2NM-30Nm versions are made of aluminum while 50-100NM version are made of alloy steel.4-6.5 thru holes located on both ends of the torque cell can be used for bolting between shafts,switches or mounting plates.Torque load cell FTA has no moving parts which makes it very durable and suitable for industrial environments,it’s applicable for torque measurement in both clockwise and anticlockwise direction, reaction torque meter FTA can also be used for rotating torque measurement under certain configuration. Disconnectable cable with mating connector is included,each torque meter will come with a calibration certificate to guarantee the performance and quality.Typical applications for this type of torque meter are for example motor torque measurement, test bench applications, screw driver calibration, twist measurement and so on. Reaction torquemeter FTA can be modified or customized as per request.
Dimensions(in milimeter)
Specifications
Capacity | 0.2N*m / 1.77 lb-in / 2kgf*cm 0.5N-m / 4.4 lbf-in / 5 kgf*cm 1Nm / 8.8 lb*in / 10 kg*cm 2N-m / 17.7 lbf-in / 20 kg-cm 3N*m / 26.5 lbf*in / 30 kgf-cm 5Nm / 44 lbf*in / 50 kgf*cm 10N*m / 88 lb-in / 100kgf*cm 20N-m / 177 lb*in / 200 kg*cm 30Nm / 265 lbf-in / 300 kg-cm 50N*m / 442 lbf*in / 500kg*cm 100N-m / 885 lb*in / 1000 kg*cm |
Rated output | 1.5 mV/V |
Excitation | 3-15V |
Zero balance | ±0.05mV/V |
Nonlinearity | ±0.2% R.O. |
Hysteresis | ±0.2% R.O. |
Nonrepeatability | ±0.1% R.O. |
Creep(10min) | ±0.1% R.O. |
Safe overload | 150% F.S. |
Ultimate overload | 200% F.S. |
Compensated temp. | -10...+40oC |
Operating temp. | -20...+60oC |
Temp. shift zero | ±0.02% R.O./oC |
Temp. shift span | ±0.02% R.O./oC |
Input resistance | 350(700) ohms |
Output resistance | 350(700) ohms |
Insulation resistance | >2000M ohms |
Ingress protection | IP50 |
Material of element | <50NM Aluminum >30NM Alloy steel |
Cable | Ø5*3000mm 4-core shielded cable with mating connector |
Wiring code | Clockwise@ Red--Excitation+ Black--Excitation- Green--Signal+ White--Signal- |
A torque sensor is a transducer that converts mechanical torque into mV signal proportional to the applied torque.The acting torsion causes deformation of the measuring element,the bonded strain gage deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally,thus the moment can be measured by measuring the output signal from the transducer.
Torque cell output: = (Power supply * Rated output) * Load / Capacity
Rated output is normally within 1mV/V~3mV/V.
Power supply is normally within 3-15V.
Load / Capacity is within 0-1.
So the torque sensor output signal is normally within -45mV...+45mV.
Example one: FTA-20Nm with 1.5mV/V rated output powered by 3.3V DC,the output range is -4.95mV...+4.95mV.
Example two: FTA-100Nm with 1.5mV/V rated output powered by 12V DC,the output range is -18mV...+18mV.
Torque sensor + Signal amplifier to deliver -5-5V 0-10V 4-20mA output.
Example: FTA-5Nm working with -5-5V amplifier,the torque-output relationship will be 0-5N*m torque in CW direction VS 0-5V output,0-5N-m torque in CCW direction VS 0-(-5V) output,which is linear within the error range.
Torque sensor + Digital meter:
-Display torque value in real time
-Peak holding to grab the maximum torque during testing
-RS485 or RS232 interface
-0-5V/0-10V/4-20mA analog output
-Switch output
Click here to download datasheet
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2008
Total Annual:
7000000-9000000
Employee Number:
100~150
Ecer Certification:
Site Member
Located in China,Forsentek Co., Limited has provided load cells,force sensors and measuring solutions to more than 30 countries all over the world. At Forsentek,you can find universal products like: Compression load cell Force sensor force transducer Button load cell Micro load cell ... Located in China,Forsentek Co., Limited has provided load cells,force sensors and measuring solutions to more than 30 countries all over the world. At Forsentek,you can find universal products like: Compression load cell Force sensor force transducer Button load cell Micro load cell ...
Get in touch with us
Leave a Message, we will call you back quickly!