| Overload Capacity | 1.5 times the sensor range is allowed (1.2 times for ranges above 60MPa) |
| Operating Temperature | -20℃ ~ 70℃ |
| Burst Pressure | 2 times the sensor range (1.5 times for ranges above 60MPa) |
| Output Signal | 4mA ~ 20mA DC, 1V ~ 5V DC, RS485, etc. (optional) |
| Delivery Time | 5-8 work days |
| Long-Term Stability | 0.2%F.S per year |
| Payment Terms | L/C,D/A,D/P,T/T,Western Union |
| Pressure Type | Gauge pressure, absolute pressure, negative pressure (optional) |
| Accuracy | ±0.1%F.S, 0.25%F.S, 0.5%F.S (optional) |
| Supply Ability | Production output can be flexibly adjusted according to order quantity. |
| Range | 0-5kPa ~ 260MPa (see the selection table for details) |
| Communication Protocol | MODBUS RTU protocol, HART protocol |
| Power Supply | 10V ~ 30V DC (24V DC power supply is recommended) |
| Packaging Details | Carton Package/Wooden Crate Package |
| Model Number | FD80A |
| Place of Origin | China |
| Certification | IP65/IP68 |
| Brand Name | FRD |
View Detail Information
Explore similar products
FD80A Intelligent Compact Gauge Pressure Transducer 4-20 MA Hirshmann
FD80B High Precision Industrial Pressure Transmitter IP65 Explosion Proof
Temperature Transmitter
FRD FD3051S LT Single Flange Pressure Transmitter – Smart Diaphragm Level &
Product Specification
| Overload Capacity | 1.5 times the sensor range is allowed (1.2 times for ranges above 60MPa) | Operating Temperature | -20℃ ~ 70℃ |
| Burst Pressure | 2 times the sensor range (1.5 times for ranges above 60MPa) | Output Signal | 4mA ~ 20mA DC, 1V ~ 5V DC, RS485, etc. (optional) |
| Delivery Time | 5-8 work days | Long-Term Stability | 0.2%F.S per year |
| Payment Terms | L/C,D/A,D/P,T/T,Western Union | Pressure Type | Gauge pressure, absolute pressure, negative pressure (optional) |
| Accuracy | ±0.1%F.S, 0.25%F.S, 0.5%F.S (optional) | Supply Ability | Production output can be flexibly adjusted according to order quantity. |
| Range | 0-5kPa ~ 260MPa (see the selection table for details) | Communication Protocol | MODBUS RTU protocol, HART protocol |
| Power Supply | 10V ~ 30V DC (24V DC power supply is recommended) | Packaging Details | Carton Package/Wooden Crate Package |
| Model Number | FD80A | Place of Origin | China |
| Certification | IP65/IP68 | Brand Name | FRD |
| High Light | FRD SENSOR FD80A pressure transmitter ,high-precision industrial pressure transmitter ,intelligent pressure monitoring device | ||
The FD80A intelligent pressure transmitter is a mature mass-produced industrial pressure measuring device from FRD SENSOR. Adopting advanced monocrystalline silicon sensing technology, it features compact structure and high protection grade, suitable for pressure detection of gas, liquid and steam media. It supports 4-20mA, HART and RS485 Modbus multi-signal output, converting field pressure values into standard industrial signals for PLC, DCS and remote IoT systems. With strong overload resistance, impact resistance and low temperature drift, it stably serves chemical, water treatment, HVAC, power and other industrial automation scenarios.
| Range | 0-5kPa ~ 260MPa (see the selection table for details) |
| Pressure Type | Gauge pressure, absolute pressure, negative pressure (optional) |
| Overload Capacity | 1.5 times the sensor range is allowed (1.2 times for ranges above 60MPa) |
| Burst Pressure | 2 times the sensor range (1.5 times for ranges above 60MPa) |
| Accuracy | ±0.1%F.S, 0.25%F.S, 0.5%F.S (optional) |
| Long-Term Stability | 0.2%F.S per year |
| Operating Temperature | -20℃ ~ 70℃ |
| Power Supply | 10V ~ 30V DC (24V DC power supply is recommended) |
| Output Signal | 4mA ~ 20mA DC, 1V ~ 5V DC, RS485, etc. (optional) |
| Communication Protocol | MODBUS RTU protocol, HART protocol |
| Electrical Interface | GDM connector, aviation connector, cable gland with direct lead, IP68 protection cable with direct lead |
| Protection Level | IP65, IP68 |
| Explosion-Proof Rating | Ex ia IIC T4 Ga, Ex d IIC T6 Gb, Ex tD A21 IP66 T80℃ |
| Warranty Period | 12 months |
One device realizes three functions: differential pressure measurement, liquid level conversion and flow conversion, saving project cost.
It operates stably under high static pressure; pipeline pressure fluctuation will not affect measuring accuracy, suitable for high-pressure systems.
Built-in anti-overload structure withstands single-sided high-pressure impact and protects the sensor from field pressure error.
Supports HART debugging and RS485 network communication for remote calibration, range adjustment and data collection.
Full-range temperature compensation ensures excellent long-term stability with minimal zero and span drift.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2002
Total Annual:
1000000-5000000
Employee Number:
86~96
Ecer Certification:
Verified Supplier
.gtr-container-comp789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 20px; max-width: 100%; box-sizing: border-box; margin: 0 auto; } .gtr-container-comp789-section { margin-bottom: 25px; ... .gtr-container-comp789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 20px; max-width: 100%; box-sizing: border-box; margin: 0 auto; } .gtr-container-comp789-section { margin-bottom: 25px; ...