  1. China Acoustic Modern Acoustic Wall Panel Board for Interior Exterior Decoration Use
  2. China Acoustic Modern Acoustic Wall Panel Board for Interior Exterior Decoration Use
  3. China Acoustic Modern Acoustic Wall Panel Board for Interior Exterior Decoration Use
  4. China Acoustic Modern Acoustic Wall Panel Board for Interior Exterior Decoration Use

Acoustic Modern Acoustic Wall Panel Board for Interior Exterior Decoration Use

  1. MOQ: 60
  2. Price: CN¥16.59-18.18
  3. Get Latest Price
Application Living Room, Indoor
Keywords Accoustic Wall Panels
Size 1220*2440mm.Other Size
Material 100% Polyester Fiber, Black MDF+Polyester Fiber
Density 550kg/m3 ~ 880kg/m3
Product name ACOUSTIC WOOD PANEL WALL
After-sale Service Online Technical Support, Onsite Installation, Onsite Training, Onsite Inspection, Free Spare Parts, Return and Replacement
Noise Reduction Coefficient 1.0
Thickness Customized Thickness
Project Solution Capability graphic design, 3D model design, total solution for projects, Cross Categories Consolidation
Type Accoustic Wall Panels
Design Style Modern
Color Customized Color
Feature Eco-Friendly
Warranty More Than 5 Years
Installation glue or nail
Place of Origin Guangdong, China
Brand Name SUNHOUSE
Model Number AWP-03
Certification CE/ISO9001/ISO14001/FSC

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Application Living Room, Indoor Keywords Accoustic Wall Panels
Size 1220*2440mm.Other Size Material 100% Polyester Fiber, Black MDF+Polyester Fiber
Density 550kg/m3 ~ 880kg/m3 Product name ACOUSTIC WOOD PANEL WALL
After-sale Service Online Technical Support, Onsite Installation, Onsite Training, Onsite Inspection, Free Spare Parts, Return and Replacement Noise Reduction Coefficient 1.0
Thickness Customized Thickness Project Solution Capability graphic design, 3D model design, total solution for projects, Cross Categories Consolidation
Type Accoustic Wall Panels Design Style Modern
Color Customized Color Feature Eco-Friendly
Warranty More Than 5 Years Installation glue or nail
Place of Origin Guangdong, China Brand Name SUNHOUSE
Model Number AWP-03 Certification CE/ISO9001/ISO14001/FSC
High Light polyester acoustic baffles for office ,hanging sound absorbers for studio ,modern sound control wall panels
Polyester Fiber · Interior Acoustic Treatment

PET Polyester Fiber Acoustic Wall Panels

Decorative sound-absorbing panels for interior walls and selected ceiling applications. Compare material construction, available dimensions, sound-absorption testing, installation options and documentation requirements before specifying a product.

9 / 12 mm Thickness600 × 1200 mm600 × 2400 mmWall Acoustic Treatment
Overview

What Is a PET Acoustic Wall Panel?

PET acoustic panels are interior sound-absorbing boards made from polyester fibers. Their porous fiber structure can help absorb incident sound and reduce unwanted reflections within a room. They are used in offices, meeting rooms, classrooms, hospitality interiors and other spaces where speech clarity and reverberation control matter.

Acoustic treatment and sound insulation are not the same: a surface absorber may improve a room's sound environment, but it does not by itself make a wall soundproof or prevent noise transfer between rooms.

01 / Material & Function

How Polyester Fiber Acoustic Panels Work

Sound entering the porous fiber structure loses some acoustic energy through interaction with the material. Performance changes with panel thickness, fiber structure, frequency and mounting arrangement.

Porous PET Fiber StructureFiber-based construction provides a path for sound energy to enter the absorber instead of reflecting entirely from a hard wall.
Decorative Wall FinishCan combine interior surface treatment with acoustic design; evaluate actual colors, textures and edge finishes using physical samples.
Thickness & DensityBoth influence acoustic behavior. Nominal panel thickness alone does not establish an NRC or absorption class.
Mounting & Air GapDirect fixing and batten-mounted installations can produce different absorption results. Match the tested assembly.
Hard Interior SurfaceSound can reflect repeatedly, contributing to reverberation.
PET Acoustic TreatmentAbsorbing part of the incident sound can help control reflections.
Conceptual explanation only; not a measured acoustic test or before-and-after performance claim.
02 / Product Data

PET Acoustic Wall Panel Technical Specifications

These sizes and thicknesses follow the supplied product description. Acoustic, fire and moisture-related ratings require confirmation against the specific production model and test documentation.

Polyester fiber acoustic panel specification overview
Parameter Specification / Verification
Product Type PET Polyester Fiber Acoustic Wall Panel
Base Material Polyester Fiber (PET)
Nominal Thickness 9 mm / 12 mm
Panel Dimensions 600 × 1200 mm / 600 × 2400 mm
Area per Full Panel 0.72 m² / 1.44 m² respectively
Surface & Color Confirm available colors, felt texture and edge finishing by sample
Acoustic Performance Provide tested frequency-band absorption and NRC or αw where available
Density / Weight Request model-specific kg/m³ or kg/m² data
Moisture Performance Described as moisture resistant; verify applicable exposure and test limits
Reaction to Fire “B1” stated in the supplied description; test standard and valid report must be identified
Installation Adhesive or mechanical fixing only where approved for the product and substrate
Recommended Location Interior wall treatment; ceiling use subject to approved fixing and project requirements
Important: Neither an NRC value nor a certified B1 fire rating can be confirmed from the supplied description alone. Do not publish a numeric absorption claim without a model-matched laboratory report.
03 / Acoustic Selection

Understanding NRC, αw and Mounting Conditions

Acoustic products should be selected using test data for the relevant frequencies and installation arrangement. Two PET panels with the same thickness may perform differently because of density, fiber structure, backing and air space.

Metric What It Describes Buyer Check
NRC Noise Reduction Coefficient: a single-number summary of sound absorption derived from reverberation-room test data. Ask for the ASTM C423 test report and specimen mounting.
αw (Alpha-w) Weighted sound absorption coefficient calculated using ISO 11654. Confirm the reported rating and mounting conditions.
Frequency-Band Data Shows absorption behavior at individual test frequencies; more informative than one overall number. Review the complete measured frequency table.
Air Cavity / Backing A gap, backing substrate or alternate mounting changes how the assembly interacts with sound. Compare like-for-like tested constructions.
Do not compare an NRC measured with an air gap directly against another product tested flush to a rigid wall as though the test setups were identical. Sound absorption is not a sound transmission loss or STC rating.
04 / Verification

Acoustic & Fire Test Standards

These are relevant testing and classification references, not claims that the listed PET panel has passed them. Scope and laboratory reports must be checked for each target market.

Evaluation Reference Purpose
Sound Absorption Measurement ISO 354 Reverberation-room measurement of sound absorption.
Weighted Absorption Rating ISO 11654 Rating of sound absorption for building absorbers (αw).
US Acoustic Measurement ASTM C423 Reverberation-room measurement and absorption coefficients.
European Reaction to Fire EN 13501-1 Fire reaction classification; check exact class and application field.
B1 Declaration Check the actual report (e.g., DIN 4102-1 if that is the cited method) “B1” is ambiguous without its named test/classification system.
Fire-rating caution: A DIN 4102-1 B1 statement must not automatically be rewritten as EN 13501-1 B-s1,d0 or another European class. Classifications can depend on tested thickness, substrate and fixing method.
05 / Jobsite Guidance

PET Acoustic Panel Installation Considerations

The intended application, wall condition and required acoustic performance should determine the fixing system. Follow product-specific installation instructions and local fire requirements.

  • Substrate: Check that the surface is dry, sound, clean and suitable for the selected fixing method.
  • Direct Adhesive Fixing: Confirm adhesive compatibility with PET, the substrate and applicable fire requirements.
  • Mechanical / Batten Fixing: Use an engineered, approved fixing detail; consider the effect of any air cavity on acoustic performance.
  • Panel Layout: Plan seams, corners, outlets, edge trims and cutting waste before production.
  • Ceiling Applications: Verify fastening security, allowable panel size and fire classification for overhead use.
  • Moisture & Cleaning: Avoid assuming suitability for exterior or continuously wet areas; follow tested limits and care instructions.
06 / Material Comparison

PET Acoustic Panels vs. Fabric-Wrapped Acoustic Panels

Both systems may absorb sound, but their construction, appearance and mounting requirements are different. Acoustic comparison should be based on the same test setup.

Property PET Fiber Panel Fabric-Wrapped Absorber
Typical Construction Exposed pressed polyester fiber panel Acoustic core covered with decorative fabric
Visual Finish Visible felt-like fiber texture Fabric-covered finish
Thickness 9 / 12 mm in this described range Depends on selected construction
Acoustic Rating Depends on measured model and mounting Depends on measured assembly and mounting
Selection Consideration Direct decorative treatment and cut-to-shape layouts Fabric appearance, core thickness and frame options
07 / Common Questions

Frequently Asked Questions

Do PET acoustic panels soundproof a room?

No. They are primarily used to manage reflected sound and reverberation inside a space. Sound isolation between rooms requires a suitable wall or ceiling construction designed for transmission loss.

Is 12 mm always acoustically better than 9 mm?

Not automatically at every frequency or mounting condition. Compare absorption coefficient curves from tests conducted with consistent mounting arrangements.

What NRC value does this PET panel achieve?

No verified NRC figure was provided for the specified 9 mm or 12 mm products. Request a test report identifying specimen thickness, mounting arrangement and measured absorption.

Does “B1 fire rated” mean EN 13501-1 Class B?

No. B1 must be tied to the actual cited standard, report and product construction. The DIN and EN classifications should not be treated as interchangeable.

Are PET panels suitable for humid areas?

The supplied description states moisture resistance, but an approved exposure range or test result was not included. Verify suitability for the project's humidity, condensation and cleaning conditions.

08 / Wholesale Planning

Bulk Purchasing & Project Specification Checklist

For a comparable quotation and smoother project approval, provide the design and performance requirements together rather than requesting price by panel thickness alone.

Size & Quantity9 or 12 mm; 600 × 1200 or 600 × 2400 mm; total area, planned cuts and expected waste.
Appearance ApprovalColor references, surface texture, edge cut quality and samples from the intended production finish.
Acoustic DocumentationFull ISO 354 / ASTM C423 results, NRC or αw, specimen construction and mounting method.
Compliance & ShippingCorrect fire report, density, carton packing, delivery destination and project schedule.
Panel-area reference: 600 × 1200 mm covers 0.72 m²; 600 × 2400 mm covers 1.44 m² before cutting waste. For RFQs, identify whether quantity is net installed area or gross material area.
Technical References

Standards & Guidance Sources

Official standard descriptions provide context for acoustic assessment. Links do not represent a certification of this product.

  • ISO 354 — Measurement of Sound Absorption in a Reverberation Room
  • ISO 11654 — Rating of Sound Absorption
  • ASTM C423 — Reverberation-Room Sound Absorption Test
  • UK Government — Reaction-to-Fire Classification Guidance
PET Acoustic Wall Panels · Technical reference for B2B product evaluation · Verify all project claims against model-specific reports

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Trading Company,Exporter,Manufacturer

  • Ecer Certification:

    Verified Supplier

About Foshan Huiju One-Stop Ceiling, Flooring and Partition System Supplier Founded in 1993, Foshan Huiju Decoration Material Co. Ltd. has developed into an established supplier of decorative building materials, providing coordinated ceiling, flooring, partition and furniture board solutions for... About Foshan Huiju One-Stop Ceiling, Flooring and Partition System Supplier Founded in 1993, Foshan Huiju Decoration Material Co. Ltd. has developed into an established supplier of decorative building materials, providing coordinated ceiling, flooring, partition and furniture board solutions for...

+ Read More

Get in touch with us

  • Reach Us
  • Foshan Huiju Decoration Material Co. Ltd.
  • Weiye International Building, No. 75 Lingnan Road, Dali Town, Nanhai District, Foshan City
  • https://www.fshuiju.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement