| Payment Terms | T/T |
| Supply Ability | 200pcs/month |
| Delivery Time | 1 week |
| Packaging Details | Original Packed by Carton |
| Brand | Eltek |
| Part number | 241119.825 |
| Country of Origin | China |
| Brand Name | Eltek |
| Model Number | 241119.825 |
| Certification | CE |
| Place of Origin | China |
View Detail Information
Explore similar products
Flatpack2 Integrated 19" Marine 8kW DC Eltek Power System 85 - 300 VAC Input
48V 24kW 6U Eltek Power System 600A Flatpack2 48/3000 HE or SHE Smartpack R
Rectiverter Power Core 6kVA 1ph MB
Rectiverter Power Core 6 kVA AC 16,8 kW DC CTEJ0806.4001 Provides AC Backup
Product Specification
| Payment Terms | T/T | Supply Ability | 200pcs/month |
| Delivery Time | 1 week | Packaging Details | Original Packed by Carton |
| Brand | Eltek | Part number | 241119.825 |
| Country of Origin | China | Brand Name | Eltek |
| Model Number | 241119.825 | Certification | CE |
| Place of Origin | China | ||
| High Light | 241119.825 Rectifier Module ,3000W Eltek Flatpack2 Rectifier Module ,Eltek Flatpack2 380V Rectifier Module | ||
| Technical Specifications - FLATPACK2 380V RECTIFIER | |
| Model | Flatpack2 380/3000HE UI |
| Part number | 241119.825 |
| INPUT DATA | |
| Voltage range (nominal) | 176 - 277 VAC / 260 - 400 VDC1) |
| Voltage (operating range) | 85 - 305 VAC / 260 - 410 VDC1) |
| Frequency | 45 - 66 Hz / 15 - 18.5 Hz2) / DC1) |
| Maximum current | 18.2 ARMS |
| Power Factor | 0.99 (@ 50-100% load) |
| Protection | Fuse in both lines, varistor for transient protection, shutdown when VIN is out of range |
| OUTPUT DATA | |
| Default voltage | 381 VDC |
| Voltage range | 300 - 400 VDC |
| # Pb cell supported | 156 - 168 3) |
| Max power, nominal input | 3000 W (@VOUT ≥ 48VDC) |
| Power (maximum) @ 85 VDC / 85 VAC input | 1200 W |
| Current continuous (maximum) | 9 A (@VOUT < 336 VDC) / 7.9 A (@ VOUT = 381 VDC) |
| Hold-up time, default voltage and 1000 W load | > 20 ms; output voltage > 300 VDC at 1500 W load |
| Current sharing (10 - 100% load) | ± 5% of maximum current |
| Static Voltage regulation (10 - 100% load) | ±0.5% |
| Static voltage regulation | ±0.5% for 10 - 100% load |
| Dynamic voltage regulation | ±2.0% for 10-90% or 90-10% load variation, regulation time < 10 ms 5) |
| Ripple | < 1000 mVP-P , 30 MHz bandwidth |
| Protection | Overvoltage shutdown, Hot plug-in - Inrush current limiting, ORing diode, Fuse5), Short circuit proof, High temperature protection, Overload shutdown4) |
| OTHER SPECIFICATIONS | |
| Efficiency @ 230 VAC / 380VDC input | 96.2% / 96.6% |
| Isolation | 3.0 kVAC – input to output, 1.5 kVAC – input to earth, 1.5 kVDC – output to earth, 3.0 kVAC – CAN to primary, 3.0 kVAC – CAN to secondary |
| Alarms (Red LED) | Low mains shutdown, High and low temperature shutdown, Rectifier Failure,Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure |
| Warnings (Yellow LED) | Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage |
| Normal (Green LED) | Input and output ok |
| Acoustic noise, at nominal input and full load | < 40dBA @Tambient< 25°C / <58dBA @ Tambient> 40°C |
| MTBF (Telcordia SR-332 Issue I method III (a)) | 2 291 210h (@ Tambient = 25 °C) |
| Operating temperature (5 - 95% RH non-cond.) Output power de-rates above temp / to | -40 to +75°C (-40 to +167°F), humidity 5 - 95% RH non-condensing Output power de-rates linear from 3000W @ 50°C (122°F) to 980W @ 75°C(167°F) |
| Storage temperature | -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing |
| Dimensions[WxHxD] / Weight | 109 x 41.5 x 327 mm (4.25 x 1.69 x 13”) / < 1.95 kg (4.3 lbs) |
| DESIGN STANDARDS | |
| Electrical safety | EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC 60950-1:2013, UL 60950-1:2014, CSA C22.2 No. 60950-1-07 |
| EMC | EN 61000-6-1:2007, -6-2:2005, -6-3:2007 + A1:2010, -6-4:2007 + A1:2010, IEC61000-6-5: 2015, EN 300 386:v1.6.1, FCC CFR 47 Part 15:2013 |
| Environment | Tested according to: ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised 2011/65/EU (RoHS) & 2012/19/EU (WEEE) |
![]()
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2010
Total Annual:
20000000-50000000
Employee Number:
50~100
Ecer Certification:
Active Member
Beijing Guoguang Xingda Technology Co., Ltd. was established on April 29th, 2010. with robust business growth across multiple sectors. Currently, we have a team of 50 employees and an annual turnover of USD 200 million. Our Beijing/Shenzhen warehouse cover an area of 2000 square meters,... Beijing Guoguang Xingda Technology Co., Ltd. was established on April 29th, 2010. with robust business growth across multiple sectors. Currently, we have a team of 50 employees and an annual turnover of USD 200 million. Our Beijing/Shenzhen warehouse cover an area of 2000 square meters,...
Get in touch with us
Leave a Message, we will call you back quickly!