| Detector | UV-Enhanced CMOS Linear Array Sensor |
| Absorbance Range | 0.04~300A (Equiv. 10mm Path Length) |
| OD600 Stability/Repeatability | ≤1% |
| Supply Ability | 1000pcs |
| Name | Ultra-Micro Spectrophotometer |
| Battery Capacity | 21.6V 7000mAh |
| Absorbance Precision | 0.003Abs (0.2mm Path Length) |
| Detection Module | Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection |
| Power Adapter | 45W Fast Charging |
| Path Length | 0.2mm, 0.04mm (High-Concentration), 1.0mm (Routine) |
| Protein Detection | 0.05~400mg/mL (BSA) |
| Data Storage | 1~100,000 Records; Query, Print, USB Export, Upload to Platform |
| Packaging Details | Carton box/Wooden box |
| OD600 Absorbance Range | 0~4 Abs |
| Sample Volume | 0.5~2μL |
| Dimensions & Weight | 325mm*227mm*211mm;5.15kg |
| Light Source | Xenon Flash Lamp |
| Detection Time | <6s |
| Payment Terms | L/C,D/A,D/P,T/T |
| Nucleic Acid Detection | 2~15000ng/μL (dsDNA) |
| Absorbance Accuracy | ±2% (0.76Abs @ 260nm) |
| Delivery Time | 3-5 work day |
| Power Consumption | 25W (Standby: 10W) |
| Wavelength Range | 230nm、260nm、280nm (Three-Wavelength) |
| Brand Name | GLOMRO |
| Model Number | GLO-CWF1 |
| Place of Origin | China |
View Detail Information
Explore similar products
BAXIT BXT-N9-D Zeta Potential Analyzer 0.5-10000nm DLS Nanoparticle Size Zeta
Ultra-Micro Spectrophotometer DNA RNA Analyzer Nucleic Acid Protein Quantificati
All In One Zeta Potential Particle Size Analyzer 0.5nm-10μm Colloid Particle
Reliable Supplier BAXIT BXT-N9-D Zeta Potential Analyzer High Repeatability Lab
Product Specification
| Detector | UV-Enhanced CMOS Linear Array Sensor | Absorbance Range | 0.04~300A (Equiv. 10mm Path Length) |
| OD600 Stability/Repeatability | ≤1% | Supply Ability | 1000pcs |
| Name | Ultra-Micro Spectrophotometer | Battery Capacity | 21.6V 7000mAh |
| Absorbance Precision | 0.003Abs (0.2mm Path Length) | Detection Module | Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection |
| Power Adapter | 45W Fast Charging | Path Length | 0.2mm, 0.04mm (High-Concentration), 1.0mm (Routine) |
| Protein Detection | 0.05~400mg/mL (BSA) | Data Storage | 1~100,000 Records; Query, Print, USB Export, Upload to Platform |
| Packaging Details | Carton box/Wooden box | OD600 Absorbance Range | 0~4 Abs |
| Sample Volume | 0.5~2μL | Dimensions & Weight | 325mm*227mm*211mm;5.15kg |
| Light Source | Xenon Flash Lamp | Detection Time | <6s |
| Payment Terms | L/C,D/A,D/P,T/T | Nucleic Acid Detection | 2~15000ng/μL (dsDNA) |
| Absorbance Accuracy | ±2% (0.76Abs @ 260nm) | Delivery Time | 3-5 work day |
| Power Consumption | 25W (Standby: 10W) | Wavelength Range | 230nm、260nm、280nm (Three-Wavelength) |
| Brand Name | GLOMRO | Model Number | GLO-CWF1 |
| Place of Origin | China | ||
| High Light | Ultra-micro spectrophotometer for nucleic acid ,Three-wavelength spectrophotometer for protein ,OD600 detection instrument with warranty | ||
Produt Introduction:
The GLOMRO Ultra-micro Spectrophotometer is a high-precision biological detection instrument based on UV-Vis spectrophotometry, designed for rapid concentration and purity analysis of nucleic acids (DNA/RNA), proteins, cell lysates, and other biological samples at extremely low sample volumes (0.5~2 μL).
The instrument uses liquid column surface tension technology, requiring no cuvettes or capillaries. Detection is completed with only 0.5~2μL of sample in under 6 seconds. It is widely applicable in life science research, biopharmaceuticals, medical diagnostics, and food safety.
Multiple Detection Modules:
1. Microvolume Nucleic Acid/Protein Detection
l Wavelength range: 230nm, 260nm, 280nm (three-wavelength model); 190~850nm (full-wavelength model)
l Nucleic acid detection range: 2~15,000 ng/μL (dsDNA)
l Protein detection range: 0.05~400 mg/mL (BSA)
2. OD600 Bacterial Culture Detection
l Equipped with OD600 optical path detection system and cuvette detection module
l Directly measures bacterial culture concentration
l Absorbance range: 0~4 Abs; stability/repeatability ≤ 1%
3. Fluorescence Nucleic Acid Quantification
l Fluorescent dyes specifically bind to target substances
l DNA/RNA detection limit as low as 0.5 pg/μL (dsDNA)
lLinearity R² > 0.995; repeatability/stability < 1.5%
![]()
![]()
| Model | GLO-CWF1 | GLO-CWF2 | GLO-CWF3 | GLO-CWF4 |
| Detection Module | Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection | Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection + Fluorescence Nucleic Acid Detection | Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection | Microvolume Nucleic Acid/Protein Detection + OD600 Bacterial Culture Detection + Fluorescence Nucleic Acid Detection |
| Wavelength Range | 230nm,260nm,280nm (Three-Wavelength) | 190~850nm (Full Wavelength) | ||
| Sample Volume | 0.5~2μL | |||
| Path Length | 0.2mm, 0.04mm (High-Concentration), 1.0mm (Routine) | |||
| Light Source | Xenon Flash Lamp | |||
| Detector | UV-Enhanced CMOS Linear Array Sensor | |||
| Nucleic Acid Detection | 2~15000ng/μL (dsDNA) | |||
| Protein Detection | 0.05~400mg/mL (BSA) | |||
| Absorbance Precision | 0.003Abs (0.2mm Path Length) | |||
| Absorbance Accuracy | ±2% (0.76Abs @ 260nm) | |||
| Absorbance Range | 0.04~300A (Equiv. 10mm Path Length) | |||
| Detection Time | <6s | |||
| OD600 Absorbance Range | 0~4 Abs | |||
| OD600 Stability | ≤1% | |||
| OD600 Repeatability | ≤1% | |||
| Fluorescence Linearity | / | R²>0.995 | / | R²>0.995 |
| Fluorescence Repeatability | / | <1.5% | / | <1.5% |
| Fluorescence Stability | / | <1.5% | / | <1.5% |
| Data Storage | 1~100,000 Records; Query, Print, USB Export, Upload to Platform | |||
| Power Adapter | 45W Fast Charging | |||
| Battery Capacity | 21.6V 7000mAh | |||
| Power Consumption | 25W (Standby: 10W) | |||
| Dimensions & Weight | 325mm*227mm*211mm;5.15kg | |||
FAQ
1. Who are we?
We are based in Shanghai, China, start from 2017,sell to North America(20.00%),Western Europe(15.00%),South America(10.00%),Oceania(10.00%),Northern Europe(10.00%),Eastern Europe(10.00%),South Asia(5.00%),Southern Europe(5.00%),Central America(5.00%),Africa(5.00%),Southeast Asia(5.00%). There are total about 5-10 people in our office.
2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.What can you buy from us?
Differential Scanning Calorimeter, Thermogravimetric Analyzer, Differential Thermal Analyzer, Oxygen Bomb Calorimeter, Spot Cooler
4. Why should you buy from us not from other suppliers?
We have 10 years of experience in design and development. The price preferential benefit There is a lot of goods in stock The service is good
5. What services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,FAS,CIP,FCA,DDU,Express Delivery,DAF;
Accepted Payment Currency:USD;
Accepted Payment Type: T/T,Credit Card,Western Union;
Language Spoken:English,Chinese
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller,Other
Year Established:
2012
Total Annual:
10,000,000-20,000,000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Shanghai Glomro Industrial Co., Ltd was founded in 2012. Specializing in the production of thermal analysis machine, laboratory instrument, analytical instrument, testing equipment, industrial measurements and instruments products. Products of high quality, fashiona... Shanghai Glomro Industrial Co., Ltd was founded in 2012. Specializing in the production of thermal analysis machine, laboratory instrument, analytical instrument, testing equipment, industrial measurements and instruments products. Products of high quality, fashiona...
Get in touch with us
Leave a Message, we will call you back quickly!