China factories

Chat Now Send Email
China factory - Golead Medical Group Co.,Ltd

Golead Medical Group Co.,Ltd

  • China,Chengdu ,Sichuan
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Plasma Surgical Generator GL2000 Dual Output Console for Arthroscopic Tissue
China Plasma Surgical Generator GL2000 Dual Output Console for Arthroscopic Tissue

  1. China Plasma Surgical Generator GL2000 Dual Output Console for Arthroscopic Tissue
  2. China Plasma Surgical Generator GL2000 Dual Output Console for Arthroscopic Tissue

Plasma Surgical Generator GL2000 Dual Output Console for Arthroscopic Tissue

  1. MOQ: 1 Unit
  2. Price:
  3. Get Latest Price
Output Frequency 100 kHz +/- 10%
Working Medium Normal saline, no gas required
Net Weight 10 kg
Tip Working Temperature 40-70 C
Preset Selection 5-position selector switch
Payment Terms T/T,L/C,Western Union
Coagulation Levels 1-6 level per channel
Display LED digital display, power and impedance
Max Output Power 200 W total
Packaging Details Export-grade carton with shock-proof foam, console in moisture barrier bag, foot switch and mains cable in fitted compartments
Model GL2000
Protection Class Class II, BF applied part
Ablation Levels 1-9 level per channel
Control Panel Rotary encoder and membrane buttons, no touch screen
Dimensions 380 x 330 x 165 mm
OEM Available
Supply Ability 250 Units per Month
Input Voltage AC 100-240 V, 50/60 Hz
Delivery Time 10-20 working days after deposit
Configuration Dual output, two independent channels
Product Type Dual output low temperature plasma surgical generator
Warranty 24 months
Probe Compatibility Arthroscopic probes, long endoscopic spinal probes
Certification CE, ISO 13485
Place of Origin China
Brand Name Golead
Model Number GL2000

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Output Frequency 100 kHz +/- 10% Working Medium Normal saline, no gas required
Net Weight 10 kg Tip Working Temperature 40-70 C
Preset Selection 5-position selector switch Payment Terms T/T,L/C,Western Union
Coagulation Levels 1-6 level per channel Display LED digital display, power and impedance
Max Output Power 200 W total Packaging Details Export-grade carton with shock-proof foam, console in moisture barrier bag, foot switch and mains cable in fitted compartments
Model GL2000 Protection Class Class II, BF applied part
Ablation Levels 1-9 level per channel Control Panel Rotary encoder and membrane buttons, no touch screen
Dimensions 380 x 330 x 165 mm OEM Available
Supply Ability 250 Units per Month Input Voltage AC 100-240 V, 50/60 Hz
Delivery Time 10-20 working days after deposit Configuration Dual output, two independent channels
Product Type Dual output low temperature plasma surgical generator Warranty 24 months
Probe Compatibility Arthroscopic probes, long endoscopic spinal probes Certification CE, ISO 13485
Place of Origin China Brand Name Golead
Model Number GL2000
High Light Plasma surgical generator dual output ,Arthroscopic tissue ablation console ,High frequency electrosurgical unit

Plasma Surgical Generator GL2000 Dual Output Console

The Golead Plasma Surgical Generator GL2000 in dual output configuration is a low-temperature bipolar plasma console in a 10 kg benchtop housing, intended for installation on a fixed equipment shelf or an optional equipment trolley. Two wands can remain connected at the same time, each with its own level setting, which suits theatres that alternate between arthroscopic and endoscopic spinal work within a single list.

Key Features

  • Two independent output channels — an arthroscopic probe and a long endoscopic spinal probe can stay connected; the active channel is selected on the panel.
  • Automatic wand recognition — the console identifies the connected probe type and applies the matching power window before activation.
  • Low-temperature plasma output — working tip stays in the 40-70 C range, limiting thermal spread to cartilage, capsule and nerve-adjacent tissue.
  • Saline bipolar operation — plasma ignites in the irrigation medium, so no argon supply and no patient return pad are needed.
  • 1-9 ablation and 1-6 coagulation levels per channel — independent settings for each channel, so probe changes do not require re-dialling.
  • Knob and button control panel — rotary encoder selects channel and level, membrane keys switch mode, LED digital display shows power and impedance. No touch screen, so the panel wipes clean between cases.
  • 5-position preset selector — recalls stored settings for knee, shoulder, hip, spinal discectomy and annuloplasty.
  • Channel isolation — galvanically isolated outputs prevent cross-talk between the two connected probes.

Technical Specifications

Parameter Specification
Model GL2000
Configuration Dual output, two independent channels
Technology Bipolar low-temperature plasma, saline medium
Max Output Power 200 W total
Output Frequency 100 kHz ± 10%
Tip Working Temperature 40-70 C
Ablation Levels 1-9 per channel
Coagulation Levels 1-6 per channel
Probe Compatibility Arthroscopic probes and long endoscopic spinal probes
Display LED digital display, power and impedance
Control Panel Rotary encoder and membrane buttons
Preset Selection 5-position selector switch
Input Voltage AC 100-240 V, 50/60 Hz
Dimensions 380 x 330 x 165 mm
Net Weight 10 kg
Classification Class II, BF applied part
Warranty 24 months

Clinical Applications

Arthroscopic synovectomy, meniscal and chondral debridement, capsular release, and endoscopic spinal discectomy, annuloplasty and foraminotomy, in theatres that run both arthroscopic and spinal endoscopic lists with the same console.

Quality Assurance

Built in an ISO 13485 certified facility. Every console passes 72-hour burn-in, per-channel power calibration, channel isolation and leakage current testing, plus temperature rise verification. Delivered with CE declaration of conformity, user manual, foot switch, mains cable and shelf mounting hardware.

FAQ

Can two probes be used at once? Both probes can remain connected, but only one output is active per activation; the working channel is selected on the panel.

Is argon gas required? No. Plasma is generated in saline irrigation.

Are the two channels isolated? Yes, outputs are galvanically isolated to avoid cross-talk.

Do you offer OEM branding? Yes, panel branding, language and preset mapping can be customised.

Why Choose Golead Medical

Specialised low-temperature plasma platform and consumable manufacturer, ISO 13485 certified production, CE compliant products, in-house R&D, strict outgoing inspection, OEM & ODM capability, stable capacity and worldwide export experience.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler

  • Year Established:

    2010

  • Total Annual:

    30,000,000-50,000,000

  • Employee Number:

    200~300

  • Ecer Certification:

    Verified Supplier

Established in 2010, Golead Medical Group Co., Ltd. is a professional medical device manufacturer specializing in the research, development, manufacturing, and global distribution of innovative healthcare solutions. With a strong focus on medical imaging, minimally invasive surgery, and point-of-car... Established in 2010, Golead Medical Group Co., Ltd. is a professional medical device manufacturer specializing in the research, development, manufacturing, and global distribution of innovative healthcare solutions. With a strong focus on medical imaging, minimally invasive surgery, and point-of-car...

+ Read More

Get in touch with us

  • Reach Us
  • Golead Medical Group Co.,Ltd
  • 03/03/01, No.366, North Hupan Road, New Tianfu Zone, China(Sichuan) Free Trade Area, Chengdu, China.
  • https://www.goleadultrasound.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement