Constant potential Potential control range: | ±10V |
Brand Name | GERUISI |
Model Number | GRS-CS350M |
View Detail Information
Explore similar products
Product Specification
Payment Terms | T/T, Western Union | Constant potential Potential control range: | ±10V |
Brand Name | GERUISI | Model Number | GRS-CS350M |
High Light | Battery Laboratory Electrochemical Workstation ,Electrochemical Workstation Impedance Analyzer ,electrochemical station Analyzer |
Constant potential Potential control range: ±10V
Constant current control range: ±2.0A
Potential control accuracy: 0.1%× full scale reading ±1mV
Current control accuracy: 0.1%× full scale reading
Potential resolution: 10V(>100Hz), 3V(<10Hz)
Current sensitivity: 1pA
Potential rise time: <1S(<10mA), <10S(<2A)
Reference electrode input impedance: 1012||20pF
Current range: 2nA ~ 2A, a total of 10 stops
Tank pressure: ±21V
Maximum output current: 2.0A
CV and LSV scanning speed: 0.001mV ~ 10000V/s
CA and CC pulse width: 0.0001 ~ 65000s
Current scanning increment: 1mA@1A /mS
Potential increment during potential scanning: 0.076MV-@1V /mS
SWV frequency: 0.001 ~ 100KHz
DPV and NPV pulse width: 0.0001 ~ 1000s
AD data collection: 16bit@3.6MHz, 20bit@1KHz
DA resolution: 16bit, build time: 1S
Minimum potential increment of CV: 0.020mV
IMP frequency: 10Hz~1MHz
Low-pass filter: 8 segments programmable
Current and potential range: automatic setting
Interface communication mode: USB2.0
2. Electrochemical impedance function index
Signal generator:
Frequency response: 10Hz~1MHz
Frequency accuracy: 0.005%
Ac signal amplitude: 1mV~2500mV
Signal resolution: 0.1mV RMS
Dc bias: -10~+10V
DDS output impedance: 50
Waveform: sine wave, triangular wave, square wave
Sine wave distortion: <1%
Scanning mode: logarithm/linear, increase/decrease
Signal analyzer:
Minimum integration time: 10mS or maximum cycle time
Maximum integration time: 106 cycles or 105S
Measurement time delay: 0~105 seconds
Dc offset compensation:
Automatic potential compensation range: -10V~+10V
Current compensation range: -1A~+1A
Bandwidth Adjustment:
Automatic or manual Settings, a total of 8 levels can be adjusted
2. Electrochemical impedance function index
Signal generator:
Frequency response: 10Hz~1MHz
Frequency accuracy: 0.005%
Ac signal amplitude: 1mV~2500mV
Signal resolution: 0.1mV RMS
Dc bias: -10~+10V
DDS output impedance: 50
Waveform: sine wave, triangular wave, square wave
Sine wave distortion: <1%
Scanning mode: logarithm/linear, increase/decrease
Signal analyzer:
Minimum integration time: 10mS or maximum cycle time
Maximum integration time: 106 cycles or 105S
Measurement time delay: 0~105 seconds
Dc offset compensation:
Automatic potential compensation range: -10V~+10V
Current compensation range: -1A~+1A
Bandwidth Adjustment:
Automatic or manual Settings, a total of 8 levels can be adjusted
3. Main functions of measurement and control software
Steady state polarization: open circuit potential measurement (OCP), constant potential polarization (I-t curve), constant current polarization, dynamic potential scanning (TAFEL curve), dynamic current scanning (DGP), potential scanning-step;
Transient polarization: arbitrary constant potential step wave, arbitrary constant current step wave, constant potential step (VSTEP), constant current step;
Timing analysis: Chronopotentiometry (CP), chronogalvanometry (CA), chronogalvanometry (CC);
Voltammetry: linear sweep voltammetry (LSV) #, linear cyclic voltammetry (CV), stepped cyclic voltammetry (SCV) #, square
Wave voltammetry (SWV) #, differential pulse voltammetry (DPV) #, conventional pulse voltammetry (NPV) #, conventional difference
Split pulse voltammetry (DNPV) #, Differential Pulse current detection (DPA), dual differential Pulse Current detection (DDPA),
Three-pulse Current Detection method (TPA), Integrated Pulse Current detection method (IPAD), AC Voltammetry (ACV)
Second harmonic AC voltammetry (SHACV), Fourier transform AC voltammetry (FTACV) (the # method includes phase
Dissolution voltammetry method);
Ac impedance: Electrochemical impedance (EIS) ~ frequency scan, Electrochemical impedance (EIS) ~ time scan, electrochemical impedance (EIS) ~
Potential scanning (Mott-Schottky curve), constant current impedance test;
Charge and discharge test: battery charge and discharge, constant current charge and discharge, constant potential charge and discharge, constant current intermittent titration GITT, constant potential intermittent
Titrating PITT;
Extended measurements: Electrochemical noise (EN), galvanic corrosion measurement (ZRA), electrochemical dissolution/deposition, controlled potential electrolysis coulomb
Method (BE), solution resistance measurement, cyclic polarization curve.
No | Item | qty | Remarks | |
1 | Electrochemical workstation host | CS350M | 1 | Standard |
2 | Specialized software for testing and analysis | 1 | ||
3 | Power cord/USB data cable/electrode cable | -- | 1 each kind | |
4 | Simulated electrolytic cell (instrument self-test device) | -- | 1 | |
5 | *Computer (both desktop and laptop) | 1 | Optaonl |
Company Details
Business Type:
Manufacturer
Ecer Certification:
Site Member
Wuhan Grace New Energy Co., Ltd. is a professional in battery complete experimental equipment, battery testing equipment, and dehumidification and purification equipment. We provides customized solutions for a complete set of lithium battery Laboratory and pilot produce lines, meeting the ... Wuhan Grace New Energy Co., Ltd. is a professional in battery complete experimental equipment, battery testing equipment, and dehumidification and purification equipment. We provides customized solutions for a complete set of lithium battery Laboratory and pilot produce lines, meeting the ...