Payment Terms | T/T |
Resolution | 384×288/12μm |
Spectral Response | 8~14μm |
Frame Rate | 25/30HZ |
Typical Power Consumption | 0.5W |
Brand Name | GUIDE INFRARED |
Model Number | MID312T |
Certification | RoHS2.0 |
Place of Origin | WUHAN |
View Detail Information
Explore similar products
Power Maintenance Infrared Camera Core Uncooled 1280×1024/12μm Integrated Into
Temperature Measurement Infrared Camera Core 384x288/17um for Industrial
MAX1212T HD Infrared Camera Core 1280×1024/12μm for Clear Thermal Image /
Industrial Inspection Infrared Camera Core 640x512/12um with Temperature
Product Specification
Payment Terms | T/T | Resolution | 384×288/12μm |
Spectral Response | 8~14μm | Frame Rate | 25/30HZ |
Typical Power Consumption | 0.5W | Brand Name | GUIDE INFRARED |
Model Number | MID312T | Certification | RoHS2.0 |
Place of Origin | WUHAN | ||
High Light | 12μm infrared camera core ,uncooled lwir camera core ,uncooled infrared camera core |
Efficient & accurate temperaturemeasurement
• Temperature measurement range: -20℃~150℃,0℃~550℃
• Temperature measurement accuracy: ± 2°C or + 2%
• Mature SDK development libraryfor furtherupdates
Powerful analysis function
• Full screen temperature measurement, regional analysis, high temperature alarm, hot spot tracking, isothermal mode
Model | MID312T |
Resolution | 384*288 |
Pixel Size | 12μm |
Spectral Response | 8~14μm |
Typical NETD | ≤30mK |
Frame Rate | 25/30HZ |
Analog Video | PAL/NTSC |
Digital Video Interface | USB2.0/DVP/BT.656/LVDS |
Working Voltage | 5V±0.5V |
Typical Power Consumption | 0.5W |
Working Temperature | -40℃~70℃ |
Temperature Measurement Range | -20℃~150℃, 0℃~550℃, Customizable |
Temperature Measurement Accuracy | Greater of ±2℃ or 2% (@23℃±3℃) |
Bare Module Size (mm) | 25.4*25.4*17.6 |
Bare Module Weight | 18.5g |
Lens | Fixed Focus Athermal: 9.1/13/19/25mm |
Optional Accessories | VPC/USB2.0/USB3.0/MIPI/GigE/Cameralink/SDI/HDMI |
Our infrared detectors and thermal imaging modules are designed to provide high-quality thermal imaging solutions for a wide range of applications. We offer a range of technical support and services to help you get the most out of your product, including:
· Product training and education
· Technical troubleshooting and support
· Repair and calibration services
· Customized solutions and consulting
Our team of experienced professionals is dedicated to providing you with the highest level of service and support possible. Contact us today to learn more about our product technical support and services.
Q: What is infrared thermal imaging technology?
A: Infrared thermal imaging uses photoelectric technology to detect specific infrared band signals of thermal radiation from objects, converts these signals into images and graphics that can be visually distinguished by humans, and further calculates temperature values.
Q: What is the wavelength range for infrared thermal imaging?
A: Infrared ray, also known as infrared radiation, is an electromagnetic wave in the infrared wavelength range between visible light and microwave. Thermal infrared imaging typically refers to mid infrared imaging at 3-5μm and far-infrared imaging at 8-12μm. In these bands, the focus is on heat sources, not visible light. The human eye is sensitive to the wavelength range of about 0.4~0.7μm and cannot see longer wavelengths of thermal energy.
Q: What is the classification of infrared thermal imaging wavebands?
A: Generally speaking, infrared thermal imaging is divided into three bands: short wave, medium wave, and long wave.
Shortwave: wavelength range within 3μm;
Medium wave: wavelength range from 3μm to 5μm;
Long wave: wavelength range from 8μm to 14μm;
Q: What are the applications of infrared detectors and thermal imaging modules?
A: The infrared detectors and thermal imaging modules can be used in a variety of applications such as thermography, security & surveillance, intelligent industry, outdoor night vision observation, machine vision, smart driving, UAVs, and consumer infrared products.
Q: Does infrared thermal imaging emit radiation?
A: Infrared thermal imaging passively receives infrared signals emitted by objects and does not have radiation. As long as an object exceeds absolute zero, an infrared signal will be emitted, which is received by an infrared detector and then converted into a thermal image.
Company Details
Business Type:
Manufacturer
Year Established:
1999
Employee Number:
4000~5000
Ecer Certification:
Verified Supplier
Guide Infrared has a profound grasp of the importance of having an independent infrared industrial chain. Since 2008, we've spent decades of fearlessly investing and pushing forward in research and development, being the first to make breakthroughs in developing high-performance infrared detectors i... Guide Infrared has a profound grasp of the importance of having an independent infrared industrial chain. Since 2008, we've spent decades of fearlessly investing and pushing forward in research and development, being the first to make breakthroughs in developing high-performance infrared detectors i...
Get in touch with us
Leave a Message, we will call you back quickly!