| Starting Voltage | AC220V/110V |
| Water Flow Rate | 2.64 GPM |
| Heat Exchanger | Oxygen-free Copper Tank |
| Features | Saving-Energy |
| Place Of Origin | China |
| Ignition | Automatic Elecrical Pulse Ignition |
| Heat Output Power | 21kW |
| Exhaust System | Forced Ventilation With Fan |
| Delivery Time | 30-45 Days |
| Flue Dimension | 50MM / 60MM / 90MM |
| Supply Ability | 500,000 Pcs/year |
| Packaging Details | Plastic Film To Cover The Product, Foam Board To Support The Outer Box |
| Brand Name | HAOBANG |
| Certification | CE |
View Detail Information
Explore similar products
Loading Quantity 40HQ 780 Pcs Forced Exhaust Gas Water Heater Constant
10L Tankless Gas Water Heater Indoor Instant Shower Forced Exhaust Type
10 Liter 220V Gas Water Heater Forced Exhaust Type White LED 20Kw
12 Liter 220V Forced 2800Mpa Exhaust Type Indoor Composite Panels
Product Specification
| Starting Voltage | AC220V/110V | Water Flow Rate | 2.64 GPM |
| Heat Exchanger | Oxygen-free Copper Tank | Features | Saving-Energy |
| Place Of Origin | China | Ignition | Automatic Elecrical Pulse Ignition |
| Heat Output Power | 21kW | Exhaust System | Forced Ventilation With Fan |
| Delivery Time | 30-45 Days | Flue Dimension | 50MM / 60MM / 90MM |
| Supply Ability | 500,000 Pcs/year | Packaging Details | Plastic Film To Cover The Product, Foam Board To Support The Outer Box |
| Brand Name | HAOBANG | Certification | CE |
| High Light | Instant Constant Temperature Gas Water Heater ,21kW Forced Exhaust NG Unit | ||
Every parent knows the anxiety of watching a toddler reach for the shower controls, uncertain whether the water will scald delicate skin or deliver an unexpected cold shock. Our 10L Instant Constant Temperature Gas Water Heater addresses this universal concern through engineering that prioritizes unwavering temperature stability above all else. The moment water begins flowing, an electronic ignition sequence initiates combustion, and within seconds the proportional gas valve modulates flame intensity to match the precise thermal load required. The result is a shower experience where the temperature you select remains locked within a half-degree tolerance regardless of whether a washing machine simultaneously draws hot water or a toilet flushes elsewhere in the home. For families navigating the chaos of morning routines, this predictability transforms the bathroom from a source of stress into a sanctuary of reliable comfort, allowing parents to focus on getting children ready rather than constantly adjusting taps.
| Logo/Pattern | Silk Screen Printing |
| Safety Features | Flame Failure Protection, Overheat Protection |
| Nominal Heat Input | 21KW |
| Heat Exchanger | Oxygen Free Copper |
| Ignition Type | Electronic Ignition |
| Body Size | 530*330*143 MM |
| Rated Voltage | AC220V |
| Flue Dimension | 50MM / 60MM / 90MM |
| Type Of Gas | NG |
| Temperature Range | 35-80 Degree |
The physical envelope measures 530 millimetres in width, 330 millimetres in height, and a slim 143 millimetres in depth, enabling installation in narrow utility closets and behind cabinet doors that would reject bulkier alternatives. Thermal efficiency reaches ninety-three percent or higher, validated through standardized testing protocols that measure energy input against usable heat output. Water pressure compatibility spans from 0.02 to 0.8 pascals, ensuring reliable ignition across diverse plumbing infrastructures from rural wells to urban high-rise distribution systems. The natural gas inlet accepts standard G1/2 inch threaded connections at 2000 pascals nominal pressure, with electronic pulse ignition replacing wasteful standing pilot systems. A forced exhaust fan actively draws combustion gases through the heat exchanger and propels them through flue pipes of 50, 60, or 90 millimetre diameter, maintaining safe indoor air quality regardless of external wind conditions or building pressure differentials.
Family homes with young children represent the primary installation environment for this safety-optimised model, particularly in master bathrooms where temperature consistency matters most for bathing infants and toddlers. The wall-mounted configuration suits both new construction and retrofit applications where existing floor-standing tanks have reached end of life. When installing in a semi-outdoor utility area or enclosed balcony, ensure the space receives adequate ambient air for combustion and that the flue path remains unobstructed by seasonal decorations or stored items. Wall mounting requires structural verification, particularly in older homes where plasterboard or timber-frame walls may need reinforcement. Maintain the prescribed clearances for maintenance access, and position the flue terminal well away from operable windows to prevent exhaust gas entry during ventilation periods. Professional installation by a licensed gas fitter is mandatory, with particular attention to gas tightness testing at all joints before operational approval.
Beyond the headline constant-temperature capability, this unit incorporates a comprehensive safety ecosystem including flame-failure detection, overheat protection at 176 degrees Fahrenheit, and dry-burn prevention that halts operation if water flow ceases unexpectedly. The touch-panel interface presents current temperature and operational status through a clear LED display, with intuitive controls that even young family members can understand under parental guidance. For wholesale partners and property developers, the platform offers flexible OEM arrangements encompassing housing colour matching, branded faceplates, and regional voltage or gas pressure adaptations. Container logistics optimise per-unit shipping costs, with seven hundred eighty units fitting within a standard forty-foot high-cube container. After-sales support includes a one-year warranty, proportional spare parts allocation, and multilingual technical manuals that simplify installer training across diverse markets.
This heater is not designed for installation inside fully sealed bathrooms or sleeping quarters where oxygen consumption and combustion product accumulation create unacceptable risks. It cannot operate safely with gas pressures outside the specified 2000 pascal natural gas range without internal component modification. Prolonged continuous operation exceeding normal residential patterns will degrade components prematurely and invalidate warranty terms. Users should establish a monthly routine of visually inspecting the flue termination for obstructions such as bird nests or leaf accumulation, and annually testing the flame-failure protection by observing automatic shutdown when gas supply is temporarily interrupted. Water with elevated mineral content requires more frequent inlet filter maintenance to prevent scale migration into the heat exchanger passages, which would otherwise compromise both efficiency and temperature precision.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1997
Total Annual:
7000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
.gtr-container-d3f4g5 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-d3f4g5 p { font-size:... .gtr-container-d3f4g5 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-d3f4g5 p { font-size:...
Get in touch with us