China White 86*90*43mm Heated Floor Thermostat Temperature Controller For Warm Floor
China White 86*90*43mm Heated Floor Thermostat Temperature Controller For Warm Floor

  1. China White 86*90*43mm Heated Floor Thermostat Temperature Controller For Warm Floor
  2. China White 86*90*43mm Heated Floor Thermostat Temperature Controller For Warm Floor

White 86*90*43mm Heated Floor Thermostat Temperature Controller For Warm Floor

  1. MOQ: 64 pcs
  2. Price: FOB $9.5~$10.5
  3. Get Latest Price
Payment Terms Western Union, T/T,Paypal
Supply Ability 10000pcs/month
Delivery Time 10 workdays
Packaging Details 64 pcs in one carton
Model No. SK50
Limitation setting 5℃~60℃
Switch differential factory setting 1℃
Customized Customized
Display Type LCD
Application HVAC system
Brand Name Saiko
Model Number SK50
Certification CE,RoHs
Place of Origin Jiangsu

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms Western Union, T/T,Paypal Supply Ability 10000pcs/month
Delivery Time 10 workdays Packaging Details 64 pcs in one carton
Model No. SK50 Limitation setting 5℃~60℃
Switch differential factory setting 1℃ Customized Customized
Display Type LCD Application HVAC system
Brand Name Saiko Model Number SK50
Certification CE,RoHs Place of Origin Jiangsu
High Light electric underfloor heating thermostatunderfloor heating programmable thermostat

Instruction:


   Weekly circulation digital programming thermostatwith LCD screen,which has 6-event everyday.Manual mode and programme mode could be selec-ted.The thermostat is recommended for control ofelectric heating devices or on/off valve actuator usedin hydronic floor heating.

 

Parameters:
 

Voltage 220V/230V
Power consumption 2W
Housing material Self-extinguishing
Setting range 5~90ºC
Protective housing IP20

 

Dimension:

 

Display:

Sensor failure:

 

 E0:Built-in sensor short-circuited or disconnected.

 E1:Built-in sensor short-circuited or disconnected.

 When shows E0/E1 error,thermostat must be checked till thr error is eliminated.

 

Selection:

Model Current Application
SK513 3A Built-in&floor sensor,floor limit sensor weekly programme
SK523 3A Built-in&floor sensor,floor limit sensor weekly programme,a potential free output
SK50 16A Built-in&floor sensor,floor limit sensor weekly programme

 

Wiring diagram:

More products for you to choose:

 

FAQ

 

1.How long will it take for the underfloor heating system to warm up?

   The warm up time of an electric underfloor heating system will be dictated by the insulation used beneath it and the output of the system. In general, the better insulated the sub-floor the faster the system will warm up, with Underfloor Insulation boards?facilitating a very speedy warm up time of as little as 15 minutes, and un-insulated concrete floors causing the slowest warm up time. Using a?200W system?beneath ceramic/stone tiles provides a faster warm up time than 150W system.

 

2. Can I turn my heating on the day it is fitted?

   If you have installed your heating beneath tile adhesive, levelling compound or a screed you must allow this to dry out before turning on your system for the first time. If the system is turned on too early it will force the moisture out of the covering which may lead it to crack. We would recommend speaking to the manufacturer of your flexible tile adhesive, grout or screed to confirm the drying time required.

 

3. Does each room require its own thermostat?

   We would recommend that each room has its own heating system controlled by its own thermostat. This will allow for simpler and more accurate temperature control of each room and will avoid heating rooms which do not require it.
 
 

Install 

  • 1,Open main control panel, with 3.5mm slotted point screwdriver along the inclined plane until to card depths of 4mm, pry up slightly to open the card hook
  • 2,Connect back panel and power, wire as per wiring diagram, fasten back panel on cassette with M4 screw
  • 3,Connect winding displacement of back panel and upper panel
  • 4,Hang up with 30° to 2 hooks, press on the 2 bottom corners, stuck on the upper shell, installation finished. 
 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2015

  • Employee Number:

    20~40

  • Ecer Certification:

    Site Member

  Heated floor thermostat.com   We started producing electric in-floor heating in Jiangsu,China almost eight years ago in 2011 and have been growing steadily ever since. In 2015 we started selling our own specially-designed lines of in-floor heating products and two years later once...   Heated floor thermostat.com   We started producing electric in-floor heating in Jiangsu,China almost eight years ago in 2011 and have been growing steadily ever since. In 2015 we started selling our own specially-designed lines of in-floor heating products and two years later once...

+ Read More

Get in touch with us

  • Reach Us
  • Nanjing Saiko Controls Co.Ltd
  • No.40 Ailing Road, Moling Street, Jiangning District, Nanjing
  • https://www.heatedfloorthermostat.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement