| Payment Terms | T/T,L/C |
| Supply Ability | 300MVA/year |
| Delivery Time | 25 days |
| Packaging Details | Plywood case |
| Winding Material | Copper & Aliuminum are optional |
| Rated capacity | 400KVA |
| Primary voltage | 11kV ±2×2.5% |
| Secondary voltage | 0.4kV |
| Warranty | 1 year |
| Type | Oil filled distribution power transformer |
| Brand Name | HENTG POWER |
| Model Number | S11-400-11/0.4 |
| Certification | IEC, CE, ISO9001 |
| Place of Origin | China |
View Detail Information
Explore similar products
IEC60076 High Efficiency 630kVA 10/0.4 Copper Winding Oil-Immersed Transformer
250kVA 10kV to 0.4kV Oil-Immersed Distribution Power Transformer for Rural
High Efficiency Oil Immersed Power Distribution Transformer 400kVA 10kV 0.4kV
Professional 500kVA 10kV 0.4KV Distribution Type Transformer for Unstable
Product Specification
| Payment Terms | T/T,L/C | Supply Ability | 300MVA/year |
| Delivery Time | 25 days | Packaging Details | Plywood case |
| Winding Material | Copper & Aliuminum are optional | Rated capacity | 400KVA |
| Primary voltage | 11kV ±2×2.5% | Secondary voltage | 0.4kV |
| Warranty | 1 year | Type | Oil filled distribution power transformer |
| Brand Name | HENTG POWER | Model Number | S11-400-11/0.4 |
| Certification | IEC, CE, ISO9001 | Place of Origin | China |
| High Light | 400kVA oil-immersed power transformer ,11kV three-phase distribution transformer ,ONAN cooling industrial transformer | ||
The HENTG POWER 400kVA oil-immersed transformer is designed for 11kV primary / 0.4kV secondary distribution in commercial complexes and industrial factory environments.
Rated at 50Hz, ONAN (Oil Natural Air Natural) cooling, this three-phase transformer meets IEC 60076 standards.
It is optimized for Nigeria’s grid conditions and tropical ambient temperatures (up to 45°C), providing reliable step-down power from 11kV medium voltage to 400V three-phase / 230V single-phase end-user supply.
IEC 60076-compliant core & windings – Grain-oriented silicon steel (M5 grade, 0.23mm thickness) reduces no-load loss by consistent magnetic flux density (1.65T).
Sealed tank design (corrugated wall) – Expansion corrugated fins absorb oil volume variation from -5°C to +55°C ambient, eliminating conservator-related leakage risks.
High overload capacity – ONAN cooling allows 1.2x continuous overload for 6 hours within 45°C ambient without winding hotspot exceeding 105°C (class A insulation, 220°C cellulose paper).
Dyn11 vector group – Handles unbalanced loads common in Nigerian commercial clusters (shops, factories with welding equipment).
Low noise operation – ≤55 dB(A) at 1m distance, measured per IEC 60076-10.
Anti-condensation treatment – HV/LV bushing sealing with NBR rubber (shore A 70±5) and hydrophobic coating on terminals for high-humidity coastal regions (Lagos, Port Harcourt).
Rated power: 400kVA
Primary voltage: 11kV ±2×2.5%
Secondary voltage: 0.4kV
Frequency: 50Hz
Vector group: Dyn11
Impedance voltage: 4.5% (±5%)
Core: Step-lap stacked, cold-rolled grain-oriented silicon steel (M5, 0.23mm).
LV winding: Copper foil (99.9% purity) – better short-circuit withstand than aluminum.
HV winding: Copper wire (F class insulation, 155°C rated).
Insulation paper: Thermally upgraded kraft paper (220°C melting point, permittivity 3.5).
Tank: 3mm steel plate, hot-dip galvanized (Zn coating ≥ 85μm) for corrosion resistance in Nigeria’s humid/saline environment.
Altitude: ≤ 1000m (customizable for Jos Plateau via derating)
Ambient temperature: -5°C to +45°C
Humidity: ≤ 95% non-condensing
Corrugated tank with no rubber gasket on main body (only on manhole and bushings).
Gaskets: HNBR (Hydrogenated Nitrile) for oil resistance, compression set ≤ 20% after 1000h at 120°C.
Bushing sealing torque: factory set at 25Nm ±2Nm, with dual O-ring grooves.
Paint system: Epoxy primer (80μm) + polyurethane topcoat (80μm) – passed salt spray test 720h (ASTM B117) with no creepage.
Frequent grid surges and voltage fluctuations cause internal arcing and gasket aging.
High ambient temperature (up to 45°C) + tropical humidity accelerate rubber seal degradation.
Poor road conditions during transport lead to tank weld stress cracks.
Local maintenance culture often lacks torque wrenches, leading to over/under-tightened bushing nuts.
| Questions | HENTG POWER design measure | Evidence / specification |
|---|---|---|
| Thermal expansion stress | Corrugated tank with pre-calculated fin volume | Oil expansion volume: 0.45L per 10°C rise for 400kVA; fin capacity = 18L reserve |
| Gasket hardening | HNBR (Hydrogenated Nitrile Butadiene Rubber) | Compression set ≤ 20% after 1000h @ 120°C; oil swell ≤ 10% in 72h (ASTM D471) |
| Weld cracking | Full-penetration robotic welding + X-ray inspection | 100% of main tank welds tested per ISO 17636; no weld repair allowed without re-X-ray |
| Over-tightening damage | Torque-limiting markings on bushing nuts | Factory marking at 25Nm; ±10% tolerance visible after installation |
| Corrosion under gasket | Zinc-rich primer + silicone sealant at joints | Salt spray resistance 720h (ASTM B117) – no red rust |
| Sand/dust ingress | IP54-rated terminal box (on request) | With optional IP54 enclosure for LV side (standard is IP44) |
In internal accelerated aging tests (85°C oil temperature, 90% RH, 500h cycle), the corrugated tank and HNBR gaskets showed zero visible leakage; torque retention remained within 22-28Nm range.
Q1: Can this transformer handle 33kV primary? We sometimes have 33kV feeders in industrial zones.
A: The standard model is 11kV primary. For 33kV applications, we offer a variant with 33kV bushings and reinforced insulation (36kV rated, BIL 170kV). Please specify voltage at order.
Q2: How do you prevent oil leakage during transport on bad roads from Lagos to Kano?
A: All HENTG POWER transformers are shipped with zero oil (dry). We use nitrogen-filled tank pressure (0.2 bar) to detect weld leaks before shipment. After installation, first oil fill is done on-site – this eliminates transit vibration leakage.
Q3: What is the standard warranty and do you have a local agent in Nigeria?
A: 24-month warranty from commissioning date or 30 months from shipment, whichever earlier. We have a technical partner in Lagos with stock of bushings, gaskets, and DGA test kits. Service response within 48 hours.
Q4: Can we use this transformer for a cold storage facility with frequent on/off cycling?
A: Yes – the Dyn11 vector group and copper winding (low thermal expansion mismatch) tolerate daily load cycles. However we recommend no more than 4 full load cycles per day to avoid cumulative insulation stress. For frequent switching (e.g., 10 cycles/day), we suggest optional load tap changer (OLTC) – consult HENTG POWER engineering.
Q5: What type of transformer oil is pre-filled? Can we use local oil?
A: Factory-filled with inhibited mineral oil (IEC 60296, grade A, breakdown voltage ≥ 60kV/2.5mm). Local oil can be used only if it meets same dielectric strength and pour point (-30°C) – we advise sending sample to our lab for compatibility test.
Q6: What grounding system do you recommend for Nigerian factories (TN-C or TT)?
A: The LV winding (0.4kV side) comes with a removable neutral link. For TN-C systems, we recommend solid neutral grounding. For TT, use the neutral link with surge arrester (MOV 275V) – not included but can be ordered as accessory.
HENTG POWER specializes in medium-voltage oil-immersed transformers (50kVA to 10MVA) for emerging markets, with a dedicated engineering team for tropical and high-salinity environments.
IEC 60076-1 to -10 compliant design (Type-tested at KEMA or equivalent independent lab)
ISO 9001:2015 production facility
Short-circuit withstand test passed: 400kVA model at 11kV, 4.5% impedance, 25 cycles (IEC 60076-5)
Core cutting: Silencer shear line with 0.02mm accuracy, step-lap joints.
Vacuum drying & oil filling: Residual moisture ≤ 0.5% in insulation (measured by Karl Fischer).
Pressure leak test: 0.3 bar air pressure for 12 hours – zero drop allowed.
Partial discharge (PD) test: ≤ 10pC at 1.1× rated voltage (IEC 60076-3).
Every transformer shipped with individual oil sample test report (breakdown voltage, moisture, dielectric dissipation factor).
Customizable for 50Hz grid fluctuations (±10% voltage, ±5% frequency) – internal design margin for +15% voltage.
10-year spare parts availability commitment for gaskets, bushings, and cooling fins.
Company Details
Business Type:
Manufacturer
Year Established:
2011
Total Annual:
300-500MVA
Employee Number:
150~200
Ecer Certification:
Verified Supplier
.gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-x7y2z9 p { font-si... .gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-x7y2z9 p { font-si...
Get in touch with us
Leave a Message, we will call you back quickly!