| Phase | Three Phase |
| Packaging Details | Wooden Case |
| Noiselevel | Less than 65 dB |
| Supply Ability | 5 |
| Rated Voltage | 35KV,13.2KV,10KV,6.3KV,22KV 20KV 33KV |
| Capacity | 500kVA/Custom Designed |
| Mountingtype | Indoor / Outdoor |
| Payment Terms | L/C,D/A,D/P,T/T,Western Union |
| Connection Group Label | Dyn11 (customizable) |
| Impedancevoltage | 4% to 6% |
| Material | Aluminum, Copper Winding |
| Delivery Time | 35 |
| Model Number | YB-500-10 |
| Brand Name | HENTG POWER |
| Certification | CE |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
Modular Outdoor Energy Storage Cabinet / Containerized ESS Solution
35KV Three Phase Compact Substation for Solar Plant with Industrial Controls
11KV 2000KVA Oil-Immersed Box Type Substation Intelligent HV/MV Transformer for
35KV Three Phase Compact Transformer Substation for Solar Plant Combination and
Product Specification
| Phase | Three Phase | Packaging Details | Wooden Case |
| Noiselevel | Less than 65 dB | Supply Ability | 5 |
| Rated Voltage | 35KV,13.2KV,10KV,6.3KV,22KV 20KV 33KV | Capacity | 500kVA/Custom Designed |
| Mountingtype | Indoor / Outdoor | Payment Terms | L/C,D/A,D/P,T/T,Western Union |
| Connection Group Label | Dyn11 (customizable) | Impedancevoltage | 4% to 6% |
| Material | Aluminum, Copper Winding | Delivery Time | 35 |
| Model Number | YB-500-10 | Brand Name | HENTG POWER |
| Certification | CE | Place of Origin | CHINA |
The 500kVA Compact Ring Main Unit (RMU) Substation is an integrated, factory-assembled power distribution solution engineered specifically for residential communities, urban complexes, and small-scale utility networks. This space-optimized unit combines a hermetically sealed oil-immersed distribution transformer with a fully enclosed SF6 gas-insulated ring main unit inside a single weatherproof enclosure. Meeting rigorous IEC 62271-202 and IEC 60076 standards, it safely and efficiently transforms medium voltage (up to 12kV) down to low voltage (400/230V), delivering dependable electricity directly at the load center with minimal footprint and reduced installation complexity.
| Rated Capacity | 500 kVA (ONAN self-cooled) |
| High Voltage | 6.6 kV, 11 kV or customizable up to 12 kV, with off-circuit tap changers (±2*2.5%) |
| Low Voltage | 400/230 V, three-phase four-wire |
| Vector Group | Dyn11 (standard) |
| Frequency | 50/60 Hz |
| Cooling Method | Oil Natural Air Natural (ONAN) via corrugated tank fins |
| Transformer Type | Hermetically sealed oil-immersed design with elastic corrugated walls to compensate oil thermal expansion — no conservator, maintenance-free |
| Dielectric Fluid | Mineral oil (bio-degradable natural ester fluid available as an option) |
| Efficiency | Low-loss design in line with IEC 60076 energy performance tiers |
| Type | SF6 gas-insulated, sealed pressure system |
| Typical Configuration | 2 incoming feeders + 1 transformer feeder (fuse-switch combination or vacuum circuit breaker); 3-way and 4-way options available |
| Rated Voltage | 12 kV / 24 kV |
| Busbar Rated Current | 630 A |
| Transformer Feeder Protection | DIN-type HV HRC fuses (up to 63 A) or microprocessor relay with circuit breaker |
| Internal Arc Classification | IAC A-FL (optional) for operator safety |
| Gas Pressure Monitoring | Manometer with optional low-pressure alarm contacts |
| Enclosure Construction | 2 mm galvanized steel with anti-corrosion polyester powder coating (C4/C5-M available) |
| Ingress Protection | IP54 for transformer compartment; IP44 for ventilation with vermin-proof mesh |
| Approximate Dimensions | 2200 mm (L) * 1300 mm (W) * 1800 mm (H) |
| Total Mass | ~2,800 kg (transport weight, including oil and RMU) |
| LV Distribution | Built-in low-voltage cabinet with MCCB, CT metering compartment provisions, and anti-condensation heater |
| Earthing | Double earth terminals with continuous earth bar |
A: The recommended pad-mounted foundation is approximately 2400 mm * 1500 mm, based on the standard enclosure footprint. We provide dimensioned civil drawings and base frame details upon technical confirmation to ensure accurate site preparation.
A: Yes. While the standard 2-incoming + 1-transformer-feeder layout is widely used, we can configure the RMU with 3-way or 4-way options, include a vacuum circuit breaker for the transformer feeder, and integrate motorized actuators and RTU interfaces for SCADA remote control.
A: Absolutely. The substation is type-tested to IEC 62271-202 and IEC 60076. We routinely adapt protection and metering schemes to align with individual utility requirements worldwide. Complete test reports, single-line diagrams, and compliance certificates are supplied with every unit.
A: The transformer and RMU are both maintenance-free under normal conditions. The sealed oil system prevents sludge and moisture ingress, while the sealed-for-life SF6 RMU requires no gas refilling. We recommend only an annual visual check of the pressure gauge, enclosure condition, and ventilation filter cleanliness.
A: We employ grain-oriented silicon steel, step-lap core joints, and anti-vibration pads to significantly reduce core noise. The standard unit operates below 45 dB(A). For noise-sensitive projects, we can upgrade to an acoustic enclosure package that further attenuates sound levels.
A: The package includes the fully wired and tested compact substation, installation manuals, and factory test certificates. Lead time is generally 8–10 weeks after drawing approval. We also offer on-site supervision during installation and cold commissioning by our field service engineers.
Company Details
Business Type:
Manufacturer
Year Established:
2011
Total Annual:
300-500MVA
Employee Number:
150~200
Ecer Certification:
Verified Supplier
.gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-x7y2z9 p { font-si... .gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-x7y2z9 p { font-si...
Get in touch with us
Leave a Message, we will call you back quickly!