View Detail Information
Explore similar products
Power Prefabricated Box Type Substation Solar Wind Compatible 50/60Hz Three
New Energy Outdoor Step Up/Step Down Electricity 20MVA 10MVA 5000VA Power
PV Inverter Boost Cabinet 500kW | Integrated Solar Power Conversion and Storage
HENTG Power CE Certified 220kV 50Hz 5000kVA Box Type Compact Substation for
Product Specification
| High Light | 35kV oil immersed power transformer ,5000kVA Dyn11 transformer ,ONAN oil immersed transformer | ||
A BESS transformer (Battery Energy Storage System transformer) is a critical component that connects the battery system to the grid by stepping voltage up or down and ensuring safe, stable power flow. It is typically designed to handle bi-directional energy transfer, frequent load cycling, and harmonics generated by inverters.
In most projects, the BESS transformer works between the PCS (Power Conversion System) and the medium-voltage grid, with common configurations such as 0.4/13.8 kV or 0.69/33 kV. Key design considerations include thermal performance, overload capability, harmonic tolerance, and insulation reliability.
At HENTG POWER, BESS transformers are engineered for high efficiency, compact footprint, and long service life, making them ideal for renewable integration, peak shaving, and grid stabilization applications.
| Product Parameters | ||||
|---|---|---|---|---|
| Basic Technical Parameters | 2 | Insulation & Thermal Classes | ||
| Type & Model | S11-5000-33/0.69 | Insulation Level | Class A | |
| Rated Capacity | 5000kVA | a | High-Voltage Side | |
| Rated Voltage(HV / LV) | 33kv/0.69kv | Lightning Impulse Withstand(peak) | 200kv | |
| Rated Current(HV / LV) | 87.5A /4183.7 A | Short-Duration Power-Frequency Withstand(r.m.s.) | 85kv | |
| Voltage Ratio | ±2 × 2.5 % | Lightning Impulse Withstand (peak) | ||
| Short-Circuit Impedance | 7% | Short-Duration Power-Frequency Withstand (r.m.s.) | 5kv | |
| Vector Group | Dyn11 | |||
| Rated Frequency | 50Hz | |||
| Cooling Method | ONAN | |||
| Losses, Noise & No-Load Current | 4 | Other Technical Requirements | ||
| No-Load Loss | ≤ 3970W (+15%) | 4 | Overall Dimensions (L × W × H) | 2650 mm × 2900 mm × 2750 mm |
| Load Loss | ≤ 39018W (+15%) | b. | Estimated Total Mass | 10.7t |
| Sound Pressure Level | ≤ 77 dB(A) | |||
| No-Load Current | 0.50% | |||
| Feature | Advantage | Benefit |
|---|---|---|
| Integrated Design | Combines inverter,transformer,and HV distribution | Fewer devices, savesspace and installationtime |
| Modular Structure | Standardized componentsfor quick deliveryand easy O&M | Lower O&M costs,higher reliability |
| High-efficiency Inverter | >98.5% conversionefficiency | Minimizes power loss,improves energyconversion efficiency |
| Smart Monitoring System | Real-time monitoring& remote control | Efficient management and fault alerts |
| Comprehensive Protection | Over-voltageover-current short-circuit protection | Ensures safe operation for both equipment and personnel |
| All-weather Adaptability | IP54 rating,works in harsh environments | Applicable in deserts,plateaus and more |
A: Most projects use medium-voltage step-up transformers connecting the inverter/PCS to the grid, with common ratings like 0.4/20 kV or 0.69/30 kV. Depending on the layout, you’ll see pad-mounted, compact substations, or skid-mounted solutions combining transformer + RMU.
A: Yes. Transformers must comply with IEC 60076 for general design and IEC 62930 (project-level integration context).
In addition, Ecodesign (EU) 548/2014 sets minimum efficiency requirements, which are mandatory for grid-connected transformers.
A: BESS transformers must handle:
This requires careful design in cooling, insulation, and harmonic mitigation.
A:At HENTG POWER, we provide:
Company Details
Business Type:
Manufacturer
Year Established:
2011
Total Annual:
300-500MVA
Employee Number:
150~200
Ecer Certification:
Verified Supplier
.gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-x7y2z9 p { font-si... .gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-x7y2z9 p { font-si...