View Detail Information
Explore similar products
50Hz Oil Immersed Pad Mounted Distribution Transformer Three Phase 100KVA To
Three Phase Substation Oil Immersed Transformer Electrical Mv Voltage Transforme
1000 KVA Tap Changer Step Up Step Down Transformer Mv Hv IP54 Protection Pre
Compact Substation Electricity Power Trafo Transformer Mv 3 Phase Oil Type
Product Specification
The low-noise 200kVA Compact Ring Main Unit (RMU) Substation is a fully integrated, factory-built power distribution package designed for residential pockets, quiet suburban communities, and rural electrification networks where sound sensitivity matters. This space-efficient unit combines a hermetically sealed oil-immersed distribution transformer with a three-way SF6 gas-insulated ring main unit, all housed inside a single, tamper-resistant metal enclosure. Meeting IEC 62271-202 and IEC 60076 standards, it steps medium voltage down to safe low-voltage levels and delivers reliable three-phase power precisely where it is needed, while keeping land use, on-site labor, and long-term maintenance to an absolute minimum.
| Rated Capacity | 200 kVA (ONAN self-cooled) |
|---|---|
| High Voltage | 6.6 kV, 11 kV, or customizable up to 12 kV, with off-circuit tap changer (±2×2.5%) |
| Low Voltage | 400/230 V, three-phase four-wire |
| Vector Group | Dyn11 (standard) |
| Frequency | 50/60 Hz |
| Cooling | Oil Natural Air Natural (ONAN) via corrugated tank fins |
| Tank Design | Hermetically sealed, fully oil-filled with elastic corrugated fins for thermal expansion — no conservator or silica gel breather needed |
| Dielectric Fluid | Mineral oil (natural ester fluid available for environmentally sensitive locations) |
| Efficiency | Low-loss core and winding design compliant with IEC 60076 energy performance requirements |
| Type | SF6 gas-insulated, sealed pressure system |
|---|---|
| Configuration | 2 incoming cable feeders + 1 transformer protection feeder (standard 3-way); 4-way option available |
| Rated Voltage | 12 kV / 24 kV |
| Busbar Rated Current | 630 A |
| Transformer Feeder Protection | DIN-type HV HRC fuse combination (appropriately rated fuses for 200 kVA) or vacuum circuit breaker with digital relay |
| Internal Arc Classification | IAC AFL (optional) for enhanced operator safety |
| Gas Monitoring | Integrated pressure gauge with low-pressure alarm contact interface |
| Enclosure Material | 2 mm galvanized sheet steel with anti-corrosion polyester powder coating |
|---|---|
| Ingress Protection | IP54 for transformer and switchgear compartments; IP44 for ventilation with rodent-proof stainless steel mesh |
| Approximate Dimensions | 1800 mm (L) × 1100 mm (W) × 1600 mm (H) |
| Approximate Total Mass | 1,800 kg (transport weight, including oil and RMU) |
| LV Cabinet Integration | Provision for main MCCB, CT-operated metering, and anti-condensation heater |
| Safety Earthing | Continuous copper earth bar with dual external earth terminals |
A: Only a simple flat concrete pad of about 2000 mm × 1300 mm is required, along with prepared underground cable entries. We supply a detailed civil foundation drawing and pre-positioned cable gland plate to guide your contractor.
A: Yes. The low-voltage cabinet can be divided into separate lockable compartments for the utility's kWh meter, CTs, and the customer's incoming breaker, meeting most utility segregation requirements.
A: Absolutely. The RMU can be equipped with motor-operated disconnectors and an RTU interface. The transformer can include temperature sensors linked to an alarm loop, allowing full remote condition monitoring.
A: By sealing the tank completely, no outside air or moisture can enter the oil, preventing oxidation and sludge formation. Combined with the maintenance-free SF6 RMU, only annual visual inspections of gauges, enclosure, and ventilation are recommended.
A: The standard unit operates below 45 dB(A) at full load. We achieve this through high-grade grain-oriented silicon steel, step-lap core joints, and internal vibration dampening pads. For noise-critical projects, an enhanced acoustic insulation package is available.
A: After drawing approval, the standard manufacturing lead time is 8 to 10 weeks. We also offer expedited production slots for urgent projects. On-site supervision and cold commissioning support are available as a service add-on.
Company Details
Business Type:
Manufacturer
Year Established:
2011
Total Annual:
300-500MVA
Employee Number:
150~200
Ecer Certification:
Verified Supplier
.gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-x7y2z9 p { font-si... .gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-x7y2z9 p { font-si...
Get in touch with us
Leave a Message, we will call you back quickly!