China factories

Chat Now Send Email
China factory - XIAN XIWUER ELECTRONIC AND INFO. CO., LTD

XIAN XIWUER ELECTRONIC AND INFO. CO., LTD

  • China ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China MYS5-385/20-2P(NS) Class II Surge Protective Device (SPD)
China MYS5-385/20-2P(NS) Class II Surge Protective Device (SPD)

  1. China MYS5-385/20-2P(NS) Class II Surge Protective Device (SPD)
  2. China MYS5-385/20-2P(NS) Class II Surge Protective Device (SPD)
  3. China MYS5-385/20-2P(NS) Class II Surge Protective Device (SPD)
  4. China MYS5-385/20-2P(NS) Class II Surge Protective Device (SPD)
  5. China MYS5-385/20-2P(NS) Class II Surge Protective Device (SPD)

MYS5-385/20-2P(NS) Class II Surge Protective Device (SPD)

  1. MOQ: 100
  2. Price: Negotiable
  3. Get Latest Price
SPD according to IEC 61643-11 Class II
Installation Location Indoor
Delivery Time 25~30 days
Nominal Discharge Current (In) 20kA (8/20μs)
Operating Temperature Range -40℃ ~ +70℃
Housing Material Thermoplastic, UL94 V-0
Voltage Protection Level (Up) ≤1.9kV
Minimum Conductor Cross Section 1.5mm² Solid Wire / Flexible Wire
Mounting Method 35mm DIN Rail, EN 60715
SPD according to EN 61643-11 Class 2
Protection Degree IP20
Operating Status / Fault Indication Green / Red
Bolt Type / Torque M5 / 3.0Nm ±10%
Supply Ability 3,000,000 pcs a year
Maximum Continuous Operating Voltage (Uc) 385V AC, 50/60Hz
AC Switching Capacity 125VAC/1A
Cross-sectional Area of Remote Signaling Terminal 0.2mm²
Screw Hole Type / Torque M2/0.25Nm
Packaging Details Carton
Maximum Discharge Current (Imax) 40kA (8/20μs)
Maximum Conductor Cross Section 35mm² Stranded Wire / 25mm² Flexible Wire
Response Time (ta) ≤25ns
Number of Ports 1
Remote Signaling Contact Type Floating Changeover Contact
Payment Terms L/C,T/T
AC Nominal Voltage (Un) 230V AC, 50/60Hz
DC Switching Capacity 30VDC/0.5A
Model Number MYS5-385/20-2P(NS)
Brand Name XIWUER
Place of Origin China
Certification ISO9001,ISO14001,ISO45001,CCC

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

SPD according to IEC 61643-11 Class II Installation Location Indoor
Delivery Time 25~30 days Nominal Discharge Current (In) 20kA (8/20μs)
Operating Temperature Range -40℃ ~ +70℃ Housing Material Thermoplastic, UL94 V-0
Voltage Protection Level (Up) ≤1.9kV Minimum Conductor Cross Section 1.5mm² Solid Wire / Flexible Wire
Mounting Method 35mm DIN Rail, EN 60715 SPD according to EN 61643-11 Class 2
Protection Degree IP20 Operating Status / Fault Indication Green / Red
Bolt Type / Torque M5 / 3.0Nm ±10% Supply Ability 3,000,000 pcs a year
Maximum Continuous Operating Voltage (Uc) 385V AC, 50/60Hz AC Switching Capacity 125VAC/1A
Cross-sectional Area of Remote Signaling Terminal 0.2mm² Screw Hole Type / Torque M2/0.25Nm
Packaging Details Carton Maximum Discharge Current (Imax) 40kA (8/20μs)
Maximum Conductor Cross Section 35mm² Stranded Wire / 25mm² Flexible Wire Response Time (ta) ≤25ns
Number of Ports 1 Remote Signaling Contact Type Floating Changeover Contact
Payment Terms L/C,T/T AC Nominal Voltage (Un) 230V AC, 50/60Hz
DC Switching Capacity 30VDC/0.5A Model Number MYS5-385/20-2P(NS)
Brand Name XIWUER Place of Origin China
Certification ISO9001,ISO14001,ISO45001,CCC

Product Description

The MYS5-385/20-2P Surge Protective Device (SPD) is designed for overvoltage protection in low-voltage AC power distribution systems.

It is used to protect electrical equipment from transient overvoltage caused by lightning surges, switching operations, and other electrical disturbances.

This Type 2 SPD complies with EN 61643-11 Class II and IEC 61643-11 Class II standards. It features a 385V AC maximum continuous operating voltage (Uc), 20kA nominal discharge current (In), and 40kA maximum discharge current (Imax), providing reliable surge protection performance.

The device adopts a 35mm DIN rail mounting design, suitable for installation in distribution cabinets, control panels, and other indoor electrical systems.


Product Features

  • Type 2 / Class II surge protective device
  • Nominal discharge current: 20kA (8/20μs)
  • Maximum discharge current: 40kA (8/20μs)
  • Maximum continuous operating voltage: 385V AC
  • Low voltage protection level: ≤1.9kV
  • Fast response time: ≤25ns
  • DIN rail mounting according to EN 60715
  • Operating temperature: -40℃ to +70℃
  • Green/red status indicator for operation and fault monitoring
  • UL94 V-0 flame-retardant thermoplastic housing

Applications

The MYS5-385/20-2P SPD is suitable for:

  • Low-voltage power distribution systems
  • Electrical distribution cabinets
  • Industrial control systems
  • Building electrical installations
  • Automation equipment protection
  • Indoor power supply protection systems

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter,Seller

  • Year Established:

    1976

  • Total Annual:

    240M-270M

  • Employee Number:

    390~450

  • Ecer Certification:

    Verified Supplier

Xian Xiwuer Electronic & Info. Co., Ltd. is a wholly state-owned company with a registered capital of 91.46 million RMB Yuan, owning a total assets of 315 million RMBYuan, under the jurisdiction of Xi'an State-owned Assets Supervision & Management Committee. There are about 400 employees... Xian Xiwuer Electronic & Info. Co., Ltd. is a wholly state-owned company with a registered capital of 91.46 million RMB Yuan, owning a total assets of 315 million RMBYuan, under the jurisdiction of Xi'an State-owned Assets Supervision & Management Committee. There are about 400 employees...

+ Read More

Get in touch with us

  • Reach Us
  • XIAN XIWUER ELECTRONIC AND INFO. CO., LTD
  • No.1118, Ziqiang Road, Xi'an-710015, Shaanxi, China.
  • https://www.highvoltcapacitor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement