China Kn Kjeltec Analyzer For Determination Of Protein Content In Food
China Kn Kjeltec Analyzer For Determination Of Protein Content In Food

  1. China Kn Kjeltec Analyzer For Determination Of Protein Content In Food

Kn Kjeltec Analyzer For Determination Of Protein Content In Food

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time 15 work days
Packaging Details paper case
Measurement range 0.1-250mgN (mg N)
Measurement speed 3-6 minutes/sample
Reproducibility 0.5% Relative error
Recovery 99.5% or more (1-220mgN)
Weight 35KG
Power 1800W Working voltage AC220V 50Hz
Brand Name HiYi
Model Number KN
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Delivery Time 15 work days
Packaging Details paper case Measurement range 0.1-250mgN (mg N)
Measurement speed 3-6 minutes/sample Reproducibility 0.5% Relative error
Recovery 99.5% or more (1-220mgN) Weight 35KG
Power 1800W Working voltage AC220V 50Hz Brand Name HiYi
Model Number KN Certification CE
Place of Origin China
High Light kn kjeltec protein analyzerfood kjeltec protein analyzer

KN Kjeltec Analyzer

 

 

OVERVIEW

 

The Kjeltec KN series for simple and safe distillations with different levels of automation. The KN Kjeltec Analyzer, provides the ultimate in automated Kjeldahl analysis .

 

 

FEATURES & BENEFITS

 

Testing automation:

  • Acid addition, alkali addition, distillation, titration, result calculation and printout are done fully automatically, automated sample measurement

Sample boil-off prevention:

  • Sample dilution and alkali addition methods can be arbitrarily set according to the user's sample to prevent the occurrence of sample boil-off and improve the measurement accuracy

Anti-crystallization of alkali pump:

  • Self-developed alkali pump anti-crystallization technology, solve the problem of crystallization of alkali pump, improve the reliability of the instrument

Steam Adjustable:

  • Steam pre-addition mode, steam flow rate (1~100%) can be automatically adjusted to better achieve the distillation effect and ensure the accuracy of the experiment

Dual mode titration:

  • Dual mode titration, the combination of coarse and fine titration will ensure high accuracy of results; titration methods comply with AOAC, EPA, Din, ISO and other certified methods. 
  • The titration is performed by the officially approved color titration method.

Endpoint accuracy:

  • Endpoint color user fine-tuning technology and endpoint color learning technology ensure accurate test adaptability and a more human touch

Titration cup emptying:

  • The titration cup is automatically emptied and cleaned after the sample is distilled.

Permissions and tracking:

  • Five login accounts, three levels of access, traceability of operation logs and traceability of test results

Safety protection:

  • Multiple intelligent protections such as digestion tube position detection, safety door, condensate detection, steam generator overheating, overpressure protection, liquid level detection, etc. ensure the safety of the instrument and the operator. operator safety Translated with www.DeepL.com/Translator (free version)

 

APPLICATION

 

 Can be used for the determination of nitrogen or protein content in Any type of dairy product.
 
SPECIFICATIONS 

 

 

 

Model KN580 KN680
Measurement range 0.1-250mgN(mgN) 0.1-250mgN(mgN)
Measurement speed Conventional 3-5min/ sample Conventional 3-5min/ sample
Titration accuracy Titration 1μl/ step Coarse titration 1μl/ step Fine titration 0.016μl/ step
Sample weight solid ≤ 5g liquid ≤ 20mL solid ≤ 5g liquid ≤ 20mL
Reproducibility 0.3% Relative error 0.3% Relative error
Recovery 99.5% or more 1-250mgN 99.5% or more 1-250mgN
Automaticity Automatic addition of water dilution automatic addition of alkali automatic addition of boric acid, distillation Titration and calculation programmable control automatic printing of results
Titration while distilling Optional Yes
Interface —— USB LAN RS232 WIFI
Compatibility Ammonium nitrogen Ammonium nitrogen, optional: high state nitrogen nitrate nitrogen
Nitrogen tube evacuation Optional Automatic
Auto titration AOAC-compliant color endpoint determination method
Storage capacity Data storage >100,000 sets of solution storage >10000
Power Voltage Power: 1800W Working voltage AC220V 50Hz
Volume 500mm*450mm*750mm 500mm*450mm*750mm
Weight 35KG 35KG

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2001

  • Total Annual:

    10000000-15000000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan... HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing HiYi Technology Co., Ltd
  • Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China
  • https://www.hiyipro.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement