  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Supply Ability 1000 set/month
Delivery Time 3-7 days
Packaging Details paper carton
Certifications CE, KC, RCM
Communication USB
Compliance ISO
Display 17.8 mm (7 in.) color touch screen
Model TL2360 ISO
Weight 3.0 kg
Brand Name HiYi
Model Number TL2360
Certification CE, ISO13485, ISO9001
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 1000 set/month Delivery Time 3-7 days
Packaging Details paper carton Certifications CE, KC, RCM
Communication USB Compliance ISO
Display 17.8 mm (7 in.) color touch screen Model TL2360 ISO
Weight 3.0 kg Brand Name HiYi
Model Number TL2360 Certification CE, ISO13485, ISO9001
Place of Origin China
High Light led turbidimeter portabletouch screen turbidimeter portabletouch screen hand held turbidity meter

 

TL2360 LED Turbidimeter

 

OVERVIEW

 

The TL23 Series’ large full color touch screen display and intuitive user interface accelerate setup, calibration and measurement. An easy interface and guided procedures give you confidence in your results.

 

FEATURES

 

A smart device for more reliable measurements
The TL23 Series ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability. This quality step removes subjectivity and the need for repeated measurements.

 

Trusted measurement for high turbidity applications; simplified

The new TL23 Series laboratory turbidimeters blend trusted technology and improved features to simplify testing in the most demanding wastewater and industrial applications.

 

SPECIFICATION

 

Accuracy FNU: ±2% of reading plus 0.01 FNU from 0 - 1000 FNU

FAU: ±10% of reading from 20 - 10000 NTU

NTU: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU, ±10% of reading from 4000 - 10000 NTU
Accuracy 3 Absorbance: ±0.005 Abs from 0 - 1 Abs at 860 nm

Transmittance: 0.12% T from 10 - 100% T at 860 nm
Air Purge Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975)
0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max
Hose barb connection for 1/8-inch tubing
Certifications CE, KC, RCM
Communication USB
Compliance ISO
Data Logging 2000 total logs, includes reading log, verification log and calibration log
Dimensions (H x W x D) 153 mm x 395 mm x 305 mm
Display 17.8 mm (7 in.) color touch screen
Interface 2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner
Light Source Light-emitting diode (LED) at 860 ± 30 nm
Measurement Method Nephelometric
Model TL2360 ISO
Operating Temperature Range 0 - 40 °C
Power Requirements (Amps) 3.4 A
Power Requirements (Hz) 50/60 Hz
Power Requirements (Voltage) 100 - 240 VAC
Range 0 - 10000 NTU
Range FNU (Ratio on): 0 - 1000

FNU (Ratio off): 0 - 40

FAU (auto range): 20 - 10000

NTU (Ratio on): 0 - 10000 auto decimal

NTU (Ratio off): 0 - 40

EBC (Ratio on): 0 - 2450 auto decimal

EBC (Ratio off): 0 - 9.8

Absorbance (auto range): 0 - 2.00

Transmittance (%): 1.0 - 100

Degree (mg/L): 0 - 100
Reading Modes Manual or auto range, signal averaging on and adjustable or off, ratio on or off
Regulatory Meets ISO 7027, DIN EN 27027, DIN 38404 and NFT 9033
Repeatability ±1% of reading or 0.01 FNU/NTU, whichever is greater (under reference conditions)
Response Time Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average)
Sample Cell Compatibility Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps

Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used.
Sample Requirements 25 mm sample cell: 20 mL minimum
0 to 70 °C (32 to 158 °F)
Source Lamp LED
Stabilization Time Immediately
Storage Conditions -20 to 60 °C
Units FNU, FAU, NTU, EBC, Abs (absorbance), %T (% transmittance) and mg/L
Weight 3.0 kg
What's included? TL2360 Turbidimeter, silicone oil, oiling cloth, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2001

  • Total Annual:

    10000000-15000000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan... HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing HiYi Technology Co., Ltd
  • Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China
  • https://www.hiyipro.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement