| Payment Terms | T/T, Western Union, MoneyGram, D/P, D/A, L/C |
| Supply Ability | 1000 SET / week |
| Delivery Time | 1-10 work days |
| Packaging Details | carton box : 272*200*70mm |
| Product name | PTM300 Portable Gas Chromatograph |
| Linear range | 10 5 |
| Size | (400× 130 × 315 )mm |
| weight | 5 kg |
| warranty | 1year |
| Detection limit | <1 μg/ m 3 ( benzene ) |
| Gas interface | 1/8" stainless steel ferrule |
| Column temperature | Room temperature ~ 200 ℃ , freely set |
| Brand Name | HiYi |
| Model Number | PTM300 |
| Certification | CE |
| Place of Origin | China |
View Detail Information
Explore similar products
PTM400 Handheld VOC Gas Detector for Environmental Air Quality Monitoring
PTM100 Portable VOC Analyzer With Flame Ionization Detector FID
PTM200 Portable Non-Methane Total Hydrocarbon Analyzer
GC-8850 Gas Calorific Value Analyzer For Natural Gas And Fuel Gas Testing
Product Specification
| Payment Terms | T/T, Western Union, MoneyGram, D/P, D/A, L/C | Supply Ability | 1000 SET / week |
| Delivery Time | 1-10 work days | Packaging Details | carton box : 272*200*70mm |
| Product name | PTM300 Portable Gas Chromatograph | Linear range | 10 5 |
| Size | (400× 130 × 315 )mm | weight | 5 kg |
| warranty | 1year | Detection limit | <1 μg/ m 3 ( benzene ) |
| Gas interface | 1/8" stainless steel ferrule | Column temperature | Room temperature ~ 200 ℃ , freely set |
| Brand Name | HiYi | Model Number | PTM300 |
| Certification | CE | Place of Origin | China |
| High Light | CS118 Main Control Panel ,400g Main Control Panel ,HiYi Main Control Panel | ||
PTM300 Portable Gas Chromatograph for On Site VOC Analysis with High Accuracy
The PTM300 portable gas chromatograph uses a high-sensitivity photoionization detector to detect extremely low concentrations of volatile organic compounds (VOCs) and other toxic gases. It is designed with a completely independent dual chromatographic system. The analyzer adopts an ergonomic backpack design, suitable for outdoor use. It has a built-in rechargeable lithium battery that supports continuous operation for more than 6 hours. It has a built-in small carrier gas bottle that supports fast filling; it also supports the machine to purify air as a gas chromatograph carrier gas.
![]()
1. Detection of extremely trace (ppb) volatile organic compounds (VOC);
2. Rapid detection of volatile organic gases in air, water and soil;
3. Highly sensitive detection of VOCs gas components such as benzene, toluene, xylene, styrene, etc.;
4. Equipped with a handheld data terminal (PDA), the wireless communication distance is greater than 30 meters;
5. The carrier gas uses high-purity nitrogen, helium or zero-grade air, and the built-in gas cylinder supports rapid filling;
6. Supports the use of purified air as carrier gas, and can work continuously without external carrier gas;
7. Equipped with a sampling pump and an automatic injection valve, the analysis can be completed with one click in the software workstation;
8. (Optional) Completely independent dual chromatography system, which can work simultaneously or separately;
9. The analytical column uses a 30-meter stainless steel capillary column, and the pre-column and multi-position valve realize the separation of complex components;
10. Built-in chromatographic library of more than 40 gas analyses, supports new analysis methods, and expands the spectrum library.
Application areas: industrial hygiene, indoor air quality (IAQ), detection of volatile organic compounds and aldehydes and ketones in vehicle air, benzene leakage monitoring, site characteristics monitoring, sulfide and odor gas detection.
Developable test samples: vinyl chloride, trans-1,2-dichloroethylene, cis-1,2-dichloroethylene, trichloroethylene (TCE), tetrachloroethylene (PCE), ethylene chloride, naphthalene and other ethylene oxides, ethyl chloride, ethane, alkanes (up to octane), isoprene, ethylene, propylene, butene, dichloromethane and other chloromethanes, light chlorobenzenes, hydrogen sulfide, light mercaptans, organic amines, organic sulfur (up to dimethyl disulfide), methyl ethyl ketone, arsine, phosphine, acetaldehyde, aldehydes (up to hexanal), ethylene glycol esters, fluorochloromethanes (Freon), methyl isocyanate, ethyl chloride, cyclohexanone, ethyl acrylate, light alcohols, etc.
![]()
| Main parameters | Parameter range |
| Linear range | 10 5 |
| Detection limit | <1 μg/ m 3 ( benzene ) |
| Column temperature | Room temperature ~ 200 ℃ , freely set |
| Zero drift | <1%FS/Month |
| Range drift | <1%FS/24H |
| Repeatability | ≤1% |
| power supply | Built-in lithium battery, 6 hours of battery life |
| Work Environment | -20~45° C , 20~90% RH |
| Gas interface | 1/8" stainless steel ferrule |
| weight | 5 kg |
| Overall dimensions (depth x width x height) | (400× 130 × 315 )mm |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2001
Total Annual:
10000000-15000000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan... HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan...
Get in touch with us
Leave a Message, we will call you back quickly!