| Payment Terms | L/C,D/A,D/P,T/T |
| Supply Ability | 999 |
| Brand Name | Zetron |
| Model Number | MIC300-A08 |
| Certification | CE Atex |
| Place of Origin | China |
View Detail Information
Explore similar products
MIC600S Trace Oxygen Analyzer for Industrial Gas Purity Monitoring
RC11 Smart Home Security System 200 Meters Wireless 433MHZ SOS Emergency Button
Carbon Monoxide Detector , CO Alarm Detector With Digital Display Alarm
Indoor WiFi Air Quality Monitor HCHO TVOC CO2 PM2.5 PM10 PM1.0
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T | Supply Ability | 999 |
| Brand Name | Zetron | Model Number | MIC300-A08 |
| Certification | CE Atex | Place of Origin | China |
| High Light | portable flue gas analyzer ,industrial emissions monitoring analyzer ,flue gas emissions analyzer | ||
|
Measurement parameters |
|||
|
Parameter |
Measurement range |
Accuracy |
Minimum resolution |
|
O2 |
0~25/100 Vol.% |
±0.2 Vol.% |
0.01 Vol.% |
|
CO(T9≤10S) |
0~5000/10000 ppm |
±5 ppm (0~100ppm) ±5% (≥100 ppm) |
0.1 ppm |
|
SO2 (T90≤20S) |
0~5000 ppm |
±3 ppm (0~60 ppm) ±5% (≥60 ppm) |
0.1 ppm |
|
NO(T90≤10S) |
0~5000 ppm |
±5 ppm (<100 ppm) ±5% (≥100 ppm) |
0.1 pp m |
|
NO2 (T90≤30S) |
0~1000 ppm |
||
|
Combustion efficiency |
0.0~100.0% |
|
0.1% |
|
Flue gas temperature Tgas |
-20~650℃ |
±1.0% |
0.1℃ |
|
Ambient temperature Tair |
-5℃~50℃ |
±1.0% |
0.1℃ |
|
Pump load capacity |
Negative pressure -60kPa Positive pressure 20kPa |
||
|
Sampling probe |
φ10*1000 mm , temperature resistance 650℃ |
||
|
Work environment |
Ambient temperature -5℃ to 50℃, relative humidity (0 to 95)% RH |
||
|
Overall dimensions |
250mm x 102mm x 52.5mm |
||
|
Measurement parameters |
|||
|
Parameter |
Measurement range |
Accuracy |
Minimum resolution |
|
CO (H2 compensation )(T9≤10S) |
0~2000 ppm |
±5 ppm (0~100 ppm) ±5% (≥100ppm) |
0.1 ppm |
|
COlow(T90s≤10S) |
0~500 ppm |
||
|
CO (H2 compensation)(T90s≤10S) |
0~2000 ppm |
||
|
SO2 (with CO interference)(T90≤20S ) |
0~5000 ppm |
±3 ppm (0~60 ppm) ±5% (≥60ppm) |
0.1 ppm |
|
SO2low( T90≤20s) |
0~300 ppm |
||
|
NOlow(T90≤10s) |
0~300 ppm |
±5 ppm (<100 ppm) ±5% (≥100 ppm) |
0.1 ppm |
|
NO2low(T90≤30S) |
0~100 ppm |
||
|
CO2( NDIR) |
0~20/100Vol.% |
±2%FS |
0.01 Vol.% |
|
H2S(T90≤15S) |
0~500 ppm |
±5 ppm (<100 ppm) |
0.1 pp m |
|
NH3(T90≤60S) |
0~100 ppm |
±5 ppm (<100 ppm) |
1 ppm |
|
N2O ( NDIR) |
0~1000 ppm |
±20 ppm |
1 ppm |
|
CH4 (NDIR) |
0~1 Vol.% |
±100 ppm |
100ppm |
|
Excess air coefficient |
0.00~1.99 |
|
0.01 |
|
Flue pressure Pd |
-300hPa~300hPa |
±1.0% |
0.01hPa |
|
flue gas velocity Spd |
0.1~100m/s |
±1.0% |
0.1m/s |
|
Sampling rod specifications |
|||
|
Custom sampling probe |
010x300 mm , temperature resistant 650℃ |
Custom sampling probe |
ø10*500 mm , temperature resistance 1100℃ |
|
⑦ 10*500 mm , temperature resistant 650℃ |
ø10*1000 mm , temperature resistance 1100℃ |
||
|
⑦ 10*1000 mm , temperature resistant 650℃ |
ø10x1500 mm , temperature resistant 1100℃ |
||
|
⑦ 10*1500 mm , temperature resistant 650℃ |
High humidity and low sulfur professional sampling probe |
||
|
⑦ 10*2000 mm , temperature resistant 650℃ |
With sintered pre- filter |
||
The device features a handheld design, making it compact and lightweight, with multi-functional capabilities: it can accommodate up to 7 parameters, with optional sensors for O₂, CO, NO, NO₂, SO₂, H₂S, NH₃, CO₂(NDIR), N₂O(NDIR), CH₄(NDIR), etc.; it can measure flue gas temperature, ambient temperature, and flow rate/volume; and it automatically calculates excess air coefficient, combustion efficiency, heat loss, and other parameters.
Equipped with a cross-interference compensation system, ensuring accurate detection.
It can be adapted to install two sensors of the same type but with different concentrations, allowing for instant switching between high and low concentration detection modes.
The instrument features automatic sensor detection and zero-point calibration upon power-on.
Three-stage treatment system: High-performance self-developed Peltier cooling system (optional), automatic water vapor separation device, and high-end water cutoff filter.
Equipped with a built-in Beidou positioning and satellite timing system, the data is traceable and verifiable.
The measurement process can be monitored remotely via mobile phone; an optional Bluetooth printer is available for automatic printing of average measurements.
This highly integrated, low-power device features a built-in rechargeable lithium battery, providing up to 8 hours of continuous operation. It can also be charged while in use. Monitoring data: complete, accurate, and traceable; parameters and logs are recorded fully automatically. Features include adaptive measurement for sensor overload, data encryption for storage and export, and interfaces such as a memory card slot and Type-C port. The built-in instrument diagnostic program can monitor various instrument performance parameters in real time, such as airtightness self-check and sampling flow monitoring.
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2001
Total Annual:
10000000-15000000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan... HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan...