China Multi Gas Analyzer for PPB Level Industrial Gas Detection SY-2000EX
China Multi Gas Analyzer for PPB Level Industrial Gas Detection SY-2000EX

  1. China Multi Gas Analyzer for PPB Level Industrial Gas Detection SY-2000EX
  2. China Multi Gas Analyzer for PPB Level Industrial Gas Detection SY-2000EX
  3. China Multi Gas Analyzer for PPB Level Industrial Gas Detection SY-2000EX
  4. China Multi Gas Analyzer for PPB Level Industrial Gas Detection SY-2000EX
  5. China Multi Gas Analyzer for PPB Level Industrial Gas Detection SY-2000EX

Multi Gas Analyzer for PPB Level Industrial Gas Detection SY-2000EX

  1. MOQ: 1
  2. Price: USD 5000 ~40000 PER PCS
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T
Supply Ability 1000 set/month
Delivery Time 1-10 work days
Packaging Details paper case
Model Number SY-2000EX
Certification CE
Place of Origin China
Brand Name Zetron

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T Supply Ability 1000 set/month
Delivery Time 1-10 work days Packaging Details paper case
Model Number SY-2000EX Certification CE
Place of Origin China Brand Name Zetron
SY-2000EX Explosion-Proof Trace Gas Analyzer
Photoacoustic Spectroscopy

Target gases: N2O, CO2, NH3, CH4, H2O, and others

Measurement units: ppb and µg/m³

Lower detection limit: ≤20 ppb | T90 response: ≤10 s

ENGLISH TECHNICAL DATASHEET
PRODUCT OVERVIEW

The SY-2000EX is an explosion-proof trace gas analyzer based on photoacoustic spectroscopy. It provides trace-level gas measurement with no zero drift, high accuracy, and strong resistance to background noise. The analyzer is suitable for dusty, humid, and other demanding industrial environments.

Technical Specifications
Target GasesN2O, CO2, NH3, CH4, H2O, and other configurable gases
Measurement Unitsppb; µg/m³
Explosion-Proof RatingEx d IIC T6
Operating Temperature5-45°C
Stability±2% FS over 7 days
Repeatability1%
Linearity Deviation±2% FS
Response TimeT90 ≤10 s
Lower Detection Limit≤20 ppb
Dimensions

Dimensions are shown in millimetres.

FUNCTIONS AND PERFORMANCE
Project Background
  • Continuous innovation and improvement in trace-level gas measurement technology.
  • New measurement methods are required to meet industry standards and energy-saving and emission-reduction goals.
  • Lower equipment procurement and operating costs.
  • Growing demand for compact, lightweight instruments for distributed deployment and safer production.
Instrument Functions
  • Automated analysis of target gas concentrations.
  • Large LCD with clear numerical display, rich information, and automatic screen protection.
  • Chinese and English touchscreen menu operation.
  • Selectable intermediate measurement ranges.
  • 4-20 mA current-loop output.
  • Eight-channel switching output through relays.
Technical Advantages
  • No zero drift, high accuracy, and no background noise interference.
  • Suitable for gas measurement in high-dust and high-humidity environments.
  • Intelligent digital processing with high automation and simple operation.
Typical Gas Performance
ParameterNH3CH4N2OCO2H2O
Detection Limit @ 60 s10 ppb40 ppb20 ppb250 ppb80 ppb
Detection Limit @ 120 s2.5 ppb18.5 ppb12.3 ppb61.7 ppb19.5 ppb
Response Time10 s4 s4 s4 s10 s
Measurement Range0-100 ppm0-40,000 ppm0-1,000 ppm0-5,000 ppm0-1,000 ppm

Additional specifications: accuracy ±1%; ambient temperature 0-50°C; calibration is generally not required and depends on the application.

WORKING PRINCIPLE AND APPLICATIONS
Working Principle

Each gas has a unique absorption wavelength, often described as its spectral fingerprint. This characteristic can be used to identify the gas. In photoacoustic spectroscopy, a laser modulated at a selected acoustic frequency irradiates the gas. Gas molecules absorb the laser energy and release heat, causing periodic expansion and contraction of the gas. The resulting pressure wave is detected as sound and converted into a concentration measurement.

Representative molecular absorption wavelengths

NH3 Absorption Comparison

Comparison of mid-infrared and near-infrared absorption intensity for ammonia

Typical Applications
  • Ammonia concentration analysis in fertilizer synthesis processes.
  • Natural gas pipeline concentration analysis.
  • Hydrogen quality monitoring for new-energy applications.
  • Greenhouse gas monitoring.
  • High-temperature blast-furnace gas analysis in steel plants.
  • Process gas concentration analysis in the petrochemical industry.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2001

  • Total Annual:

    10000000-15000000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan... HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing HiYi Technology Co., Ltd
  • Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China
  • https://www.hiyipro.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement