| Supply Ability | 10000 |
| Packaging Details | Product packaging can be customized and negotiated as required. |
| Payment Terms | T/T |
| Delivery Time | 5-8 workdays |
| Model Number | 10kV、35kV、110kV、220kV |
| Place of Origin | WUHAN |
| Brand Name | HKV Test |
View Detail Information
Explore similar products
SF6 Gas Insulated High Voltage Test Transformer Manufacturer China
AC Withstand Voltage Test Equipment Oil Immersed High Voltage Test Transformer
DC High Voltage Generator 60kV Withstand Voltage & Leakage Current Tester
Microprocessor Relay Protection Test Set Secondary Injection Tester for
Product Specification
| Supply Ability | 10000 | Packaging Details | Product packaging can be customized and negotiated as required. |
| Payment Terms | T/T | Delivery Time | 5-8 workdays |
| Model Number | 10kV、35kV、110kV、220kV | Place of Origin | WUHAN |
| Brand Name | HKV Test |
The HZG1101 Complete Set of Variable Frequency Series Resonance Test Equipment is designed for AC withstand voltage testing of high-voltage electrical equipment, including 10kV, 35kV, 110kV and 220kV power equipment, substations, transmission lines, transformers, generators and high-voltage cables.
The system adopts advanced variable frequency series resonance technology, using resonance between the high voltage reactor and the capacitive load to generate high voltage and high current. Compared with traditional power frequency withstand voltage test systems, it greatly reduces the required power capacity, equipment size and weight while improving waveform quality and testing safety.
The complete system consists of:
With intelligent frequency scanning, automatic tuning, multiple protection functions and modular design, this equipment is widely used in power utilities, high-voltage testing laboratories, electrical installation companies and maintenance engineering units.
| Parameter | Specification |
|---|---|
| Model | HZG1101 |
| Product Type | Variable Frequency Series Resonance Test Equipment |
| Application | AC withstand voltage testing for transformers, cables, GIS, generators, substations and transmission lines |
| Test Voltage Range | 10kV / 35kV / 110kV / 220kV / up to 1000kV (configuration dependent) |
| Output Voltage Waveform Distortion | <1.0% |
| Continuous Working Time | 15 minutes under rated condition |
| System Quality Factor (Q) | Q >50 |
| Quality Factor for Cable & Generator Testing | Q >30 (depending on load) |
| Quality Factor for Transformer & Line Testing | Q >30 (depending on load) |
| Input Power Supply | Three-phase 380V or single-phase 220V |
| Load Capacity | Full load at 380V, half load at 220V |
| Frequency Adjustment Range | 20Hz–300Hz |
| Frequency Adjustment Resolution | 0.1Hz |
| Frequency Stability | ≤0.02% |
| System Measurement Accuracy | 1.5% |
| Current Output Range | 13A–1250A |
| Temperature Rise | <60℃ |
| Protection Functions | Overvoltage protection, overcurrent protection, zero-position startup protection, surge protection, phase imbalance protection |
| Display | Large LCD screen with resonance scanning curve display |
| Data Storage | Remote data storage and printing function |
| Parameter | Specification |
|---|---|
| Rated Power | 5.5–500kW |
| Input Voltage | 380V / 220V |
| Output Voltage | 0–400V |
| Output Frequency | 20–300Hz |
| Parameter | Specification |
|---|---|
| Rated Voltage Range | 0–1000kV |
| Rated Current Range | 1–10A |
| Inductance Range | 30–600H |
| Working Time | Continuous operation for 15 minutes under rated condition |
| Parameter | Specification |
|---|---|
| Capacity Range | 3.5–500kVA |
| Input Voltage | 200V / 400V compatible |
| Function | Provides excitation power for resonance system |
| Parameter | Specification |
|---|---|
| Voltage Range | 10–1000kV |
| Capacitance Range | 300–5000pF |
| Measurement Accuracy | ±1.0% |
The series resonance principle reduces the required input power to approximately 1/Q of the test capacity, making the system suitable for field environments with limited power supply.
The modular structure eliminates bulky traditional high-power transformers. Single unit weight is ≤65kg, improving portability.
When insulation breakdown occurs, the system automatically loses resonance and reduces current, preventing large short-circuit current damage.
The resonance circuit filters harmonic components and provides a near-sine wave output with distortion below 1%.
It is suitable for AC withstand voltage testing of transformers, cables, GIS, generators, switchgear, substations and transmission lines.
It provides high voltage output with lower input power, better waveform quality and safer fault current limitation compared with traditional testing methods.
Yes. The modular structure is designed for on-site testing applications in substations and power construction environments.
Yes. The system supports automatic frequency scanning, resonance point identification and curve display.
The equipment comes with a 2-year warranty including technical support, troubleshooting assistance and replacement of manufacturing-defect components.
We provide a two-year warranty for the complete variable frequency series resonance test equipment.
Warranty service includes:
Company Details
Business Type:
Distributor/Wholesaler,Exporter,Seller
Ecer Certification:
Verified Supplier
.gtr-container-7f8g9h { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 20px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-7f8g9h p { ... .gtr-container-7f8g9h { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 20px; max-width: 960px; margin: 0 auto; box-sizing: border-box; } .gtr-container-7f8g9h p { ...
Get in touch with us
Leave a Message, we will call you back quickly!