| Supply Ability | 1000 units per month |
| Product name | Battery Management System BMS |
| Application | ups backup power supply |
| BMS Type | Master-slave BMS architecture |
| Delivery Time | 25 workdays |
| Size | 482*180*500(mm) |
| Payment Terms | L/C, T/T |
| Suitable Battery type | Lithium batteries,LFP/NMC/LTO |
| Weight | 22kg |
| Communication | RS485/CAN/TCPIP |
| Warranty | 3 Years |
| Current | 125A,160A, 250A(Optional) |
| Capacity | 100Ah/150Ah/200Ah/280Ah/314Ah/any capacity |
| Packaging Details | Cardboard box foam packaging |
| Balancing Tech | Active/passive balance(Optional) |
| Max Voltage | 350V,750V,1000V(Use according to rated voltage match) |
| Model Number | RBMS-S37-250A-350 |
| Brand Name | GCE |
| Certification | CE |
| Place of Origin | china |
View Detail Information
Explore similar products
GCE 210S 672V 250A High Voltage Master BMS With Relay Contactor Lifepo4 Bms
Master UPS BMS 768V 400A 5U Iron Case Passive Balancing High Discharge Current
RS485 / CAN UPS BMS , 216S 691.2V High Voltage Battery Management System
192V 125A UPS BMS With Relay BESS UPS Sistemas De Energia Solar Energy System
Product Specification
| Supply Ability | 1000 units per month | Product name | Battery Management System BMS |
| Application | ups backup power supply | BMS Type | Master-slave BMS architecture |
| Delivery Time | 25 workdays | Size | 482*180*500(mm) |
| Payment Terms | L/C, T/T | Suitable Battery type | Lithium batteries,LFP/NMC/LTO |
| Weight | 22kg | Communication | RS485/CAN/TCPIP |
| Warranty | 3 Years | Current | 125A,160A, 250A(Optional) |
| Capacity | 100Ah/150Ah/200Ah/280Ah/314Ah/any capacity | Packaging Details | Cardboard box foam packaging |
| Balancing Tech | Active/passive balance(Optional) | Max Voltage | 350V,750V,1000V(Use according to rated voltage match) |
| Model Number | RBMS-S37-250A-350 | Brand Name | GCE |
| Certification | CE | Place of Origin | china |
| High Light | GCE BMS High Voltage 80S 256V ,UPS Battery Management System with CAN RS485 ,High Voltage BMS with TCP/IP | ||
| Position | Code | Meaning |
|---|---|---|
| 1 | RBMS | Rack Battery Management System |
| 2 | S / D | S = Standalone (2-level: BMU+RBMS); D = Multi-cluster Parallel (3-level: BMU+RBMS+SBMS) |
| 3 | 2 / 3 | 2 = Two-wire system; 3 = Three-wire (center-tap) system |
| 4 | 0 / 4 / 7 | 0 = No screen; 4 = 4.3" HMI display; 7 = 7" HMI display |
| 5 | 125A / 160A / 250A | System rated current |
| 6 | 350 / 750 / 1000 | Voltage class: 350 = 120-350VDC; 750 = 260-750VDC; 1000 = 500-1000VDC |
| Parameter | Value / Range |
|---|---|
| Rated Current | 125A / 160A / 250A (optional) |
| Voltage Class | 350V (120-350VDC) / 750V (260-750VDC) / 1000V (500-1000VDC) |
| Max Voltage | Matched to rated voltage class |
| Power Consumption | ≤25W (3-wire system); ≤15W (2-wire system) |
| Current Sampling Accuracy | 1% FSR |
| Insulation Withstand Voltage | 2800VDC, <1mA, 1min |
| Protection Level | IP20 |
| Dimensions (W×H×D) | 482 × 180 × 500 mm |
| Net Weight | ~22 kg |
| Installation | Standard 19-inch rack mount, front-in / front-out |
| Operating Temperature | -20℃ ~ +45℃ (derate above 45℃) |
| Operating Humidity | 5% ~ 75% RH |
| Appearance / Color | RAL9005 Black Sand Texture |
| Port | Interface | Function |
|---|---|---|
| BMU-OUT | CAN | Communication with BMU; cascade BMU communication |
| COM-IN / COM-OUT | RS485 / CAN | Parallel: communicate with SBMS; Standalone: communicate with UPS/PCS external equipment |
| TCP/IP | Ethernet (RJ45) | PC connection for upper-computer software; CAT5 or above |
| HMI-A / HMI-B / 24V / GND | 3.81-4Pin | External HMI display connection / SBMS power supply |
| D1 D2 | Dry Contact (NO) | 2-channel dry contact output for charge / discharge prohibition signals |
| Function | Status | Details |
|---|---|---|
| Battery Charge & Discharge Management | Supported | Automatic charge/discharge control with configurable thresholds |
| Battery Temperature Management | Supported | Multi-point temperature monitoring and protection |
| IAP Upgrade | Supported | In-Application Programming for firmware updates |
| System Protection Parameters | Supported | User-configurable protection settings |
| Short-Circuit Protection | Supported | 1000V / 25kA / 20ms |
| Pre-Charge Function | Supported | Pre-charge circuit for safe inverter/UPS connection |
| Parallel Circulation Control | Supported | Automatic current sharing in multi-cluster setups |
| Event Record | Supported | Up to 5000 event logs |
| 3-Wire Center-Tap System | Supported (Optional) | B+ / N / B- and P+ / N / P- power terminals |
| Dual Power Supply | Supported | Battery + AC mains (85-264VAC, ≤1A); mains priority |
| Standard | Description |
|---|---|
| CE | IEC 62477-1, EN 61000-6-2 / EN 61000-6-4 |
| GB/T | GB/T 16935.1, GB/T 17626.2, GB/T 17626.5 |
| No. | Name | Description | Precautions |
|---|---|---|---|
| 1 | B+ / N / B- | Battery-side power terminals (total positive, neutral, total negative) | For 2-wire systems, do NOT connect N. Bolt: M8×16, torque 8-12N*m; cable ≥70mm² (2/0AWG) copper |
| 2 | P+ / N / P- | Load-side power terminals to UPS / DC bus | For 2-wire systems, do NOT connect N. Bolt: M8×16, torque 8-12N*m; cable ≥70mm² (2/0AWG) copper |
| 3 | AC Input | Mains AC power input (85-264VAC, ≤1A max) | Must be taken from the UPS output side. Wire: 1.0mm² (18AWG) |
| 4 | ON / OFF | Circuit breaker handle | ON = closed; OFF = disconnected. If tripped, reset to OFF first before re-closing |
| 5 | D1 / D2 | 2-channel dry contact output (NO) | Charge prohibition / discharge prohibition signals |
| 6 | Start | DC start button | Press after breaker closure; LED lights = system powered on |
| 7 | System | System status LED | Green steady = normal; Yellow steady = alarm; Red steady = fault/protection; Green flash = charging; Red flash = discharging; Red/Green alt = self-check; Yellow flash = pre-charging |
| 8 | ID DIP Switch | 4-bit DIP switch for parallel ID allocation | Must start from 1. Supports up to 15 RBMS units in parallel |
| 9 | TCP/IP | Ethernet port for PC upper-computer software | CAT5 or above; straight or crossover cable (TIA-568A / TIA-568B) |
| 10 | T-CAN / T-485 | Termination resistor switches (120Ω) | Parallel: set only on the last unit. Standalone: set based on interference / distance |
| 11 | COM-IN / COM-OUT | External communication ports | Must use the supplied twisted-pair shielded cable harness |
| 12 | HMI-A / HMI-B / 24V / GND | External display / SBMS power interface | Connect display according to silkscreen sequence |
| 13 | BMU-OUT | BMU communication interface | Cascade communication with BMU modules |
| 14 | Ground | Chassis grounding point | Must be reliably grounded; grounding resistance <1Ω |
| Name | Specification | Qty |
|---|---|---|
| Power Terminal Sheath (Black) | Black | 4 pcs (3-wire model) / 2 pcs (2-wire model) |
| Power Terminal Sheath (Orange) | Orange | 2 pcs |
| External Communication Cable | 6-core shielded, 2 meters | 1 pc |
| AC Socket (Wireable) | 250V 10A | 1 pc |
| Dry Contact Terminal | 5.08-4Pin | 1 pc |
| Terminating Resistor | 120Ω | 1 pc |
| Display Terminal | 3.81-4Pin | 1 pc |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2012
Total Annual:
23600000-30000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Hunan group control energy technology Co., Ltd. (GCE) is a high-tech company specializing in the research and development of BMS and lithium battery peripheral equipment. working in the factory: The high-performance intelligent lithium battery management system produced by our company adopts... Hunan group control energy technology Co., Ltd. (GCE) is a high-tech company specializing in the research and development of BMS and lithium battery peripheral equipment. working in the factory: The high-performance intelligent lithium battery management system produced by our company adopts...
Get in touch with us
Leave a Message, we will call you back quickly!