China factories

Chat Now Send Email
China factory - Beijing Holtop Artificial Environment Technology Co., Ltd

Beijing Holtop Artificial Environment Technology Co., Ltd

  • China,Beijing ,Beijing
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Combine Air Handling Units AHU hospital air handling units featuring real time
China Combine Air Handling Units AHU hospital air handling units featuring real time

  1. China Combine Air Handling Units AHU hospital air handling units featuring real time

Combine Air Handling Units AHU hospital air handling units featuring real time

  1. MOQ: 1pc
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms TT
Supply Ability 200000 units per year
Delivery Time Two weeks
Packaging Details box
Product name Intelligent Digital Fresh Air Ventilation System For Hospital Environments
Colour White
Feature Low noise
Application scenario Hospital
Brand Name Holtop
Model Number ODM Intelligent Hygienic Air Cooled Ahu Digital Fresh Air Ventilation System For Hospital
Certification CE
Place of Origin Beijing,China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms TT Supply Ability 200000 units per year
Delivery Time Two weeks Packaging Details box
Product name Intelligent Digital Fresh Air Ventilation System For Hospital Environments Colour White
Feature Low noise Application scenario Hospital
Brand Name Holtop Model Number ODM Intelligent Hygienic Air Cooled Ahu Digital Fresh Air Ventilation System For Hospital
Certification CE Place of Origin Beijing,China
High Light hospital air handling units with digital monitoringAHU ventilation control for hospitalscombine air handling units with real-time monitoring
Intelligent Digital Fresh Air Ventilation System for Hospital Environments
Designed specifically for hospital environments, our Intelligent Digital Fresh Air Ventilation System is a revolutionary solution for maintaining optimal indoor air quality. Leveraging advanced sensor technology and real-time digital monitoring, this system continuously analyzes air composition, detecting harmful pollutants, pathogens, and volatile organic compounds (VOCs) that pose risks to patients, medical staff, and visitors.
Holtop provides comprehensive hospital system solutions tailored to each facility's unique requirements. We analyze the actual situation of each hospital to deliver customized solutions that fully consider the needs of medical equipment, current operations, and future development.
Hospital Ventilation Requirements
Hospital air safety requirements illustration
Air Safety Requirements
Hospitals are public spaces with high concentrations of bacteria and virus carriers. Both patients and staff can carry microorganisms, making continuous air circulation and high purification essential to prevent cross-infection.
Hospital air quality requirements illustration
Air Quality Requirements
Patients are vulnerable with reduced resistance. Indoor air circulation significantly impacts recovery rates. Hospitals require excellent indoor air quality to improve treatment environments and accelerate patient recovery.
Hospital energy consumption requirements illustration
Energy Consumption Requirements
Hospital construction is energy-intensive, with air-conditioning systems accounting for over 60% of total building energy consumption. Efficient, energy-saving solutions must meet ventilation requirements while significantly reducing energy usage.
Hospital intelligentization requirements illustration
Intelligent System Requirements
Intelligentization is essential for modern hospital development, including centralized equipment control, real-time energy monitoring, and automated ventilation system operation. This represents a crucial aspect of medical environment quality and green building standards.
Hospital Ventilation Principles
Directional Airflow Control
Fresh air enters from outdoor or clean areas, flows through semi-polluted areas, then to polluted areas via pressure differentials until outdoor discharge, effectively preventing backflow.
Adequate Fresh Air Supply
Meets fresh air demands for staff and patients while considering air exchange rates and pressure differentials in polluted areas to ensure sufficient airflow.
Continuous Operation
Maintains 24-hour fresh air supply continuity, focusing on consistent hospital airflow to preserve air quality standards.
Intelligent Monitoring & Control
Automatically adjusts fresh and exhaust air based on air quality sensor data, enabling individual room or master system control for maximum energy and time savings.
Ventilation Requirements by Hospital Area
Office and conference room ventilation requirements
Office & Conference Areas
Office/duty rooms: Fresh air calculated at 4-5 air changes/hour with positive pressure maintenance. Conference rooms: Fresh air based on 2.5m²/person or 40m³/hour per person with positive pressure maintenance.
Hospital ward ventilation requirements
Patient Ward Areas
Public wards: 50-55m³/bed. Children's wards: 60m³/bed. Infection wards: 40m³/bed. All maintain negative pressure to contain contaminants.
Corridor and utility area ventilation requirements
Corridor & Utility Areas
Corridors (air supply only): 2 air changes/hour with slight negative pressure. Toilets/dirty utility rooms: 10-15 air changes/hour with negative pressure.
Digital intelligent ventilation system overview Hospital ventilation system components
Digital Intelligent Fresh Air Ventilation System
System design completeness and functional configuration directly impact overall efficiency, front-end investment, and operating costs. Holtop selects projects based on high standards, performance, configuration, and cost-effectiveness.
Customized ventilation system design Hospital area pressure differentiation diagram
We design ventilation systems according to building characteristics and user needs, creating various forms and economic standards. For hospital systems typically divided into clean, semi-polluted, and contaminated areas, we implement stepwise air pressure differentiation to control airflow from clean to polluted areas, preventing high-risk air spread.
Advanced hospital ventilation technology

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2002

  • Total Annual:

    100000000-150000000

  • Employee Number:

    600~700

  • Ecer Certification:

    Verified Supplier

.gtr-container-xyz789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; overflow-x: hidden; } .gtr-container... .gtr-container-xyz789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; overflow-x: hidden; } .gtr-container...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing Holtop Artificial Environment Technology Co., Ltd
  • No. 158, Hanjiachuan Village, Haidian District, Beijing, China
  • https://www.holtopinternational.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement