Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Industrial Air Handling Units AHU vortex module type unit designed to serve as","imgUrl":"https:\/\/img.chinax.com\/nimg\/cc\/3b\/25afe63eb89c410c859c67ccf54e-200x200-1\/industrial_air_handling_units_ahu_vortex_module_type_unit_designed_to_serve_as.jpg","attrs":{"Model Number":"HFW-560HA1","Fan type":"Axial-flow low-noise fan","Minimum Order Quantity":"1pc","Delivery Time":"Negotiate"}}
{"title":"Holtop AHU Falling Film Type Water-Cooled Screw Chiller (Heater) Water Unit","imgUrl":"https:\/\/img.chinax.com\/nimg\/7b\/d1\/73681ed76586c187e5bc762483aa-200x200-1\/holtop_ahu_falling_film_type_water_cooled_screw_chiller_28heater_29_water_unit.jpg","attrs":{"Exchanger":"High efficiency enthalpy heat exchanger","Operational Mode":"Manual \/ Auto \/ Timer","Filtration Mode":"PM2.5 purify\/Deep purify\/Ultra purify","Compressor":"High-efficiency semi-hermetic screw compressor"}}
{"title":"Holtop Dynamo vortex modular air-cooled chilled water (heat pump) unit","imgUrl":"https:\/\/img.chinax.com\/nimg\/16\/fa\/b70dbd960322883ce84706effb80-200x200-1\/holtop_dynamo_vortex_modular_air_cooled_chilled_water_28heat_pump_29_unit.jpg","attrs":{"Model":"HFW-420HA1","Nominal cooling capacity(kw)":"420.0","Nominal Heating capacity(kw)":"454.0","Nominal refrigeration input total power(kw)":"129.2"}}
{"title":"Experience Unmatched Cooling and Heating Performance with Our Industrial Air","imgUrl":"https:\/\/img.chinax.com\/nimg\/6d\/ac\/034dd9a538e60e3e454d7f174ec7-200x200-1\/experience_unmatched_cooling_and_heating_performance_with_our_industrial_air_handling_units_ahu.jpg","attrs":{"Model":"HFW-560HA1","Nominal cooling capacity(kw)":"560.0","Nominal Heating capacity(kw)":"605.0","Nominal refrigeration input total power(kw)":"172.3"}}
{"title":"Holtop 25U Series Industrial Air Conditioning System Solutions","imgUrl":"https:\/\/img.chinax.com\/nimg\/a5\/4d\/60021338c805a6e62e9570a87d7d-200x200-1\/holtop_25u_series_industrial_air_conditioning_system_solutions.jpg","attrs":{"Type":"25U Series","Insulation material":"PU","Guard plate thickness(mm)":"25","Airflow range (m3\/h)":"<40000"}}
{"title":"Holtop 50U Series Industrial Air Conditioning System Solutions","imgUrl":"https:\/\/img.chinax.com\/nimg\/a1\/3d\/2d6f8ee94d62bf7c48080deb7f6e-200x200-1\/holtop_50u_series_industrial_air_conditioning_system_solutions.jpg","attrs":{"Type":"50U Series","Insulation material":"PU","Guard plate thickness(mm)":"50","Airflow range (m3\/h)":"<100000"}}
{"title":"Industrial Air Handling Units AHU with energy recovery and electrostatic","imgUrl":"https:\/\/img.chinax.com\/nimg\/34\/ac\/7249cedfed9692d13a334f94b692-200x200-1\/industrial_air_handling_units_ahu_with_energy_recovery_and_electrostatic_filtration_for_improved_workshop_air_conditions.jpg","attrs":{"Model Number":"80C Series","Payment Terms":"TT","Insulation material":"rock wool","Airflow range (m3\/h)":"100000-280000"}}
Industrial Air Handling Units AHU Vortex Module Type
The vortex module-type air-cooled chilled water (heat pump) unit is designed to serve as cooling and heating source in semi-centralized systems. This advanced modular technology utilizes air as the cooling and heating medium, functioning as integrated central air conditioning equipment that serves as both cooling/heating source and combined unit.
System Integration
Designed to work with fan coil units, cabinet-type, ceiling-mounted air handling units, and fresh air units to form efficient semi-centralized air conditioning systems.
Key Features
Modular Combination & Hierarchical Startup: Flexible modular design without main/secondary machine distinction. Supports up to 16 units per group with hierarchical startup to reduce current impact on power grids.
Intelligent Defrosting: Multi-variable detection for precise frost determination and optimal defrost timing. Dual-system design enables interval defrosting with manual override for harsh conditions.
Flexible Application: Easy unit expansion suitable for phased investment. Compact size allows independent transport and installation without special equipment or dedicated machine rooms.
Safe Operation Control: Multiple safety protection functions with intelligent multi-variable monitoring for efficient, stable operation.
Fault Backup Operation: Dual-compressor design ensures continued operation if one compressor fails, maintaining system functionality.
Technical Specifications
Rated Voltage
Three-phase 380V/3N~
Rated Frequency
50Hz
Power Supply Voltage
±10% of rated voltage
Storage Conditions
Environmental temperature: -28 to 85℃
Control Method
Remote controller
Fan Type
Axial flow low-noise fan
Operating Range
Operating Condition
Outdoor Ambient Temperature
Outlet Water Temperature
Cooling
15℃ ≤ Temperature ≤ 48℃
5℃ ≤ Temperature ≤ 15℃
Heating
-15℃ ≤ Temperature ≤ 21℃
40℃ ≤ Temperature ≤ 50℃
Model Specifications
Model
HFW-420HA1
HFW-560HA1
HFW-840HA1
HFW-980HA1
HFW-1120HA1
Nominal Cooling Capacity (kW)
420.0
560.0
840.0
980.0
1120.0
Nominal Heating Capacity (kW)
454.0
605.0
908.0
1059.0
1210.0
Refrigeration Input Power (kW)
129.2
172.3
258.4
301.5
344.6
Heating Input Power (kW)
132.4
176.4
264.8
308.8
352.8
Compressor Quantity
3
4
6
7
8
Nominal Water Flow Rate (m³/h)
72.2
96.3
144.4
168.5
192.6
Dimensions (L*W*H mm)
3540*2280*2540
4700*2280*2540
7080*2280*2540
8240*2280*2540
9400*2280*2540
Weight (kg)
4020/4160
5350/5540
8040/8320
9370/9700
10700/11080
Important Notes
1. Nominal cooling capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 7°C, outdoor ambient temperature 35°C.
2. Nominal heating capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 45°C, outdoor dry/wet bulb temperature 7/6°C.
3. Modular unit combinations require on-site fabrication of total water piping (not provided by factory).
4. Units can be combined in groups of 1-16 units using same or different module units.
5. Control accessories must be ordered separately and include remote controller, user manual, and connection cables.