| Payment Terms | T/T, L/C |
| Supply Ability | 100,000 pcs per month |
| Delivery Time | 15 days fresh products after order confirmation. |
| Packaging Details | Standard carton packing, foam board inside for protection. |
| Product | HVAC Blower Motor |
| Supply Voltage | 240V |
| Motor Type | Permanent Split Capacitor |
| Supply Frequency | 60Hz |
| Enclosure Type | OAO(Open Air Over) |
| Current | 3A |
| Thermal Overload | Equipped With An Automatic Thermal Overload |
| Output HP | 90W |
| Phase | Single Phase |
| Speed | 1000RPM/3SPD |
| Shaft Flat | One Flat |
| Capacitor | 5.0μF/370V |
| Mounting Orientation | All Angle |
| Pole | 6P |
| Insulation Class | Class B |
| Shaft Diameter | 12.7mm/0.5" |
| Bearings | Ball Bearing |
| PF | 0.9 |
| Rotation | CW |
| Shaft Length | 130mm/5.12" |
| Flat Length | 80mm/3.15" |
| Max. Ambient Temperature | 40℃/104℉ |
| Lead Length | 700mm/27.56" |
| Motor Shell Length | 98mm/3.86" |
| Brand Name | trusTec |
| Model Number | YDK-90-6B60-PJN |
| Certification | CE、UL529388 |
| Place of Origin | Changzhou, China |
View Detail Information
Explore similar products
48 Frame Fan Coil Unit Motor - 1/4HP 230V 50/60HZ 1330RPM/3SPD
FCU Motor 110 Series Single Phase For Air Curtain Indoor Unit
Double Shaft Fan Coil Motor Asynchronous Capacitor Operating 3 speed
Double Shaft Air Conditioning Fan Coil Unit Motor with Capacitor
Product Specification
| Payment Terms | T/T, L/C | Supply Ability | 100,000 pcs per month |
| Delivery Time | 15 days fresh products after order confirmation. | Packaging Details | Standard carton packing, foam board inside for protection. |
| Product | HVAC Blower Motor | Supply Voltage | 240V |
| Motor Type | Permanent Split Capacitor | Supply Frequency | 60Hz |
| Enclosure Type | OAO(Open Air Over) | Current | 3A |
| Thermal Overload | Equipped With An Automatic Thermal Overload | Output HP | 90W |
| Phase | Single Phase | Speed | 1000RPM/3SPD |
| Shaft Flat | One Flat | Capacitor | 5.0μF/370V |
| Mounting Orientation | All Angle | Pole | 6P |
| Insulation Class | Class B | Shaft Diameter | 12.7mm/0.5" |
| Bearings | Ball Bearing | PF | 0.9 |
| Rotation | CW | Shaft Length | 130mm/5.12" |
| Flat Length | 80mm/3.15" | Max. Ambient Temperature | 40℃/104℉ |
| Lead Length | 700mm/27.56" | Motor Shell Length | 98mm/3.86" |
| Brand Name | trusTec | Model Number | YDK-90-6B60-PJN |
| Certification | CE、UL529388 | Place of Origin | Changzhou, China |
| High Light | Customized Fan Coil Motor ,90W Fan Coil Motor ,1000RPM Fan Coil Motor | ||
First, locate the nameplate on your existing motor. This is your most important source of truth. You must verify:
Voltage & Phase: Common voltages are 115V or 230V, single-phase. Warning: Operating a motor on incorrect voltage will cause it to burn out.
Horsepower (HP) or Wattage: The replacement motor must have an equal or slightly higher rating. Use conversion: 1 HP ≈ 746 Watts.
RPM (Speed): Match the full-load RPM exactly (e.g., 1075 RPM). A different speed will drastically affect airflow and system balance.
Amperage (FLA): The new motor's Full Load Amps should be equal to or greater than the original.
Frequency (Hz): Match your power supply (60Hz in North America, 50Hz elsewhere).
A motor that doesn't fit physically cannot be installed. Check:
Frame Size & Type: This standardizes dimensions (e.g., 42 Frame, 48 Frame). Match it exactly.
Shaft Specifications: Measure the diameter (common: 1/2" or 12.7mm), length, and check for a keyway.
Mounting Bracket/Holes: Ensure the bolt hole pattern matches your FCU housing.
Rotation Direction: Confirm if you need Clockwise (CW) or Counter-Clockwise (CCW) rotation. Many motors are reversible.
This choice impacts efficiency, control, and cost.
Table 1: Motor Technology Comparison
| Feature | PSC Motor (Permanent Split Capacitor) | EC Motor (Electronically Commutated) |
|---|---|---|
| Efficiency | Standard | Premium - Up to 70% more efficient |
| Speed Control | Fixed Taps (e.g., 3-Speed) | Infinitely Variable & Programmable |
| Primary Use Case | Direct, cost-effective replacement | Energy savings, modern comfort, smart building systems |
| Retrofit Complexity | Simple plug-and-play | May require control system compatibility check (0-10V, PWM) |
| Lifetime Cost | Higher (energy + maintenance) | Lower total cost of ownership |
| Noise Level | Generally higher at full speed | Typically quieter across speed range |
Note: EC motors offer superior reliability with a brushless design and precise control, but ensure your FCU's existing controls are compatible.
Multi-Speed (PSC): The traditional option. Your existing wiring will have leads for High, Medium, Low speeds.
Variable Speed (EC): Provides ultimate comfort and quiet operation by adjusting airflow continuously. Ideal for zones with varying demand.
Before purchasing and installing, confirm all items below:
Electrical Specs (V, HP, RPM, A, Hz) are matched.
Physical Dimensions (Frame, Shaft, Mounting) are compatible.
Motor Technology (PSC or EC) is selected per project needs.
For PSC Motors: A new, correct capacitor (µF & Voltage) is procured.
Thermal Protection: Motor includes built-in overload protection.
Safety Certifications: Motor carries relevant marks (e.g., UL, cUL, CE).
Wiring Diagram for the new motor is available for installation.
| Do's | Don'ts |
|---|---|
| ✅ Use the new motor's nameplate as the primary guide. | ❌ Guess on RPM or use a "close enough" speed. |
| ✅ Always replace the capacitor when installing a new PSC motor. | ❌ Reuse the old capacitor. |
| ✅ Follow the new motor's wiring diagram precisely. | ❌ Assume wiring is identical to the old motor. |
| ✅ For noise-sensitive areas, check the motor's sound rating (sones/dB). | ❌ Overlook physical clearances for capacitors or conduit boxes. |
| ✅ For EC motor retrofits, verify control signal compatibility first. | ❌ Assume an EC motor is a direct plug-and-play swap without checking controls. |
A methodical approach to FCU motor selection prevents downtime, ensures safety, and optimizes energy use. For complex retrofits, especially involving EC technology, consulting with the FCU manufacturer or a qualified HVAC technician is strongly recommended.
Need Further Assistance?
For help identifying the correct motor for your specific FCU model, please contact our support team with your existing motor's nameplate data and unit model number.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2011
Total Annual:
5 million-10 million
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Changzhou Trustec Company is working on the solutions supplier for the fan motors and the blower fans. We are capable of designing and producing the fan motors from diameter 3.3'' to 6.3'' and output power from 8W to 5KW. As the professional supplier for the fan motors and blow... Changzhou Trustec Company is working on the solutions supplier for the fan motors and the blower fans. We are capable of designing and producing the fan motors from diameter 3.3'' to 6.3'' and output power from 8W to 5KW. As the professional supplier for the fan motors and blow...
Get in touch with us
Leave a Message, we will call you back quickly!