Proportional directional valves direct operated, with electrical position feedback as pilot control valve for control systems
VT-DFP Series Valve
Features
Actuation by means of a proportional solenoid with electrical feedback
Control electronics:
VT-DFP for SY(H)DFE1
- External control electronics VT 5041-3X
Control electronics:
VT-DFPE for SY(H)DFEE
- Integrated, analog
Control electronics:
VT-DFPC for SY(H)DFEC
- Integrated, digital with CAN bus interface
Control electronics:
VT-DFPn for SY(H)DFEn
- Integrated, digital with CAN bus interface, for variable-speed operation
Control electronics:
VT-DFPC for SY(H)DFEC
- Integrated, digital with Ethernet bus interface, for variable-speed operation
Control electronics:
VT-DFPF for SY(H)DFEF
- Integrated, digital with Ethernet bus interface
Type Code:
01
02
03
04
05
06
07
08
09
10
11
-
-
/
G24
K0
/
/
V
-
*
Series
01
Pilot control valve for external electronics
VT-DFP
Pilot control valve with integrated analog electronics
VT-DFPE
Pilot control valve with integrated digital electronics (CANopen fieldbus)
VT-DFPC 1)
Pilot control valve with integrated digital electronics, variable-speed
VT-DFPn 1)
Pilot control valve with integrated digital electronics (ethernet-based bus systems)
VT-DFPD
Pilot control valve with integrated digital electronics (ethernet-based bus systems)
VT-DFPF
Control spool design
02
Standard
A
2-groove (only for replacement requirement)
B
4-groove (e.g. for HFC fluids)
C
03
Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions); only type VT-DFPD and VT-DFPF
1X
Component series 20 … 29 (20 … 29: unchanged installation and connection dimensions)
2X
04
Direct voltage 24 V
G24
05
Connector (without mating connector)
K0 2)
Installation orientation connector (VT-DFP) and/or integrated electronics (see below and "Dimensions")
06
Radially to the pump axis
0
folded 90° in the direction of the subplate with counterclockwise direction of rotation
1
folded 90° in the direction of the subplate with clockwise direction of rotation
2
Additional functions: Closed-loop control
07
– VT-DFP
no code
– VT-DFPE
Switchable pressure controller (high signal)
A
Power limitation adjustable at the OBE valve
B
Power limitation adjustable via analog input
C
Pressure controller that can be switched off (high signal)
D
– VT-DFPC
Standard
A
– VT-DFPn
Teach-in version for cyclic operation
A
Real-time version (speed calculation without teach-in)
R
– VT-DFPD
Standard
A
For variable-speed operation
N
– VT-DFPF
Standard
A
Electronics assembly
08
– VT-DFP
no code
– VT-DFPE
Standard electronics with leakage oil compensation
0
Standard electronics without leakage oil compensation
1
– VT-DFPC
Standard
0
– VT-DFPn
Standard
0
– VT-DFPD, VT-DFPF
Bus system: Sercos III
S
Bus system: CANopen over EtherSAAR
T
Bus system: servo drive over EtherSAAR
D
Bus system: Servodrive over Varan
V
Bus system: Ethernet/IP
E
Bus system: PROFINET RT
N
Bus system: Powerlink
W 4)
Actual pressure value input (see "Electrical connections")
09
– VT-DFP
no code
– VT-DFPE, VT-DFPC, VT-DFPn
Current input 4 … 20 mA
Port X1
C
Voltage input 0...10 V (standard)
Port X1
V
Voltage input 1 … 10 V
Port X1
E
Voltage input 0.5...5 V (standard)
Connection X2
F
– VT-DFPD
Voltage input 0 ... 10 V (freely configurable, parameter setting on delivery)
Port XH4
V
Voltage input 0.5 ... 5 V (freely configurable, parameter setting on delivery)
Port X2M1
F
– VT-DFPF
Voltage input 0 ... 10 V (freely configurable, parameter setting on delivery)
Port XH1
V
Voltage input 0.5 ... 5 V (freely configurable, parameter setting on delivery)
Port X2N
F
Seal material (observe compatibility of seals with hydraulic fluid used, see "Technical data")
10
FKM seals
V
11
Further details in the plain text
SAAR specialized in pumps, motors, valves, bearings, couplings, gearbox, engine spare parts, filter elements, fittings, connectors, electronic components and accessories, mobile equiupment spare parts.
Rexroth VT-DFP Series Valves on Sale, Short lead time, Best price!!!
SAAR is your best, safest & quickest partner in China to buy machinery and electronic components. You just need to send us the part number or tell us the brand and sepcifiSAARion you are looking for, we'll make the quotation for you asap.
So wherever you're, if you're looking for ... SAAR is your best, safest & quickest partner in China to buy machinery and electronic components. You just need to send us the part number or tell us the brand and sepcifiSAARion you are looking for, we'll make the quotation for you asap.
So wherever you're, if you're looking for ...