China factories

Chat Now Send Email
China factory - Shenzhen Zhong Jian South Environment Co., Ltd.

Shenzhen Zhong Jian South Environment Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China ZJNF Clean Room Laminar Flow Hood Ffu Fan Filter Unit With Separated Parts Hepa
China ZJNF Clean Room Laminar Flow Hood Ffu Fan Filter Unit With Separated Parts Hepa

  1. China ZJNF Clean Room Laminar Flow Hood Ffu Fan Filter Unit With Separated Parts Hepa

ZJNF Clean Room Laminar Flow Hood Ffu Fan Filter Unit With Separated Parts Hepa

  1. MOQ: 1
  2. Price: Negotiate
  3. Get Latest Price
Payment Terms tt lc PayPal credit card
Delivery Time 18 days
Packaging Details plywood/wooden package
Frame Material Stailess Steel/Aluminum
FFU size 575*575*320 mm
HEPA size 570*570*69 mm
Air flow 400-600 m³/h
Voltage 110V/120V 50HZ/60HZ
Efficiency 99.99% H14
Brand Name ZJNF
Model Number FFU 2X2
Certification CE
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms tt lc PayPal credit card Delivery Time 18 days
Packaging Details plywood/wooden package Frame Material Stailess Steel/Aluminum
FFU size 575*575*320 mm HEPA size 570*570*69 mm
Air flow 400-600 m³/h Voltage 110V/120V 50HZ/60HZ
Efficiency 99.99% H14 Brand Name ZJNF
Model Number FFU 2X2 Certification CE
Place of Origin China
High Light Clean room laminar flow hood FFUFFU fan filter unit with HEPA filterSeparated parts fan motor FFU

The national standards for laminar flow hoods mainly follow the relevant requirements of the "Code for Design of Cleanrooms" (GB 50073) and the "Good Manufacturing Practice for Drugs" (GMP). The core indicators include:


Cleanliness level: Critical areas must reach level 100 (ISO 5) or higher.
Wind speed: The wind speed in a Class 100 cleanroom should be controlled at around 0.45m/s, with a deviation of no more than ± 20%.
Air volume: The air volume of a Class 100 clean room generally needs to reach 3000 cubic meters per hour or more.
Efficient filtration: HEPA or ULPA filters are required, with a filtration efficiency of ≥ 99.97% for particles ≥ 0.3 μ m.
Positive pressure control: The work area needs to maintain a positive pressure of 5-10 Pa to prevent external pollution.


In addition, attention should be paid to material selection (such as stainless steel), noise control (usually ≤ 65dB (A)), and installation and maintenance requirements.


The replacement cycle of high-efficiency filters in laminar flow hoods is usually between 1 and 3 years, depending on the usage environment, protection of the pre filter, and actual operating parameters.


The key influencing factors include:
Usage environment: For places with high cleanliness requirements such as hospital operating rooms and pharmaceutical workshops, it is recommended to replace them every 6-12 months; Ordinary office or home environments can be appropriately extended to 1-2 years.
Pre filter: If the initial and intermediate filters are properly maintained, they can effectively protect high-efficiency filters and extend their lifespan to more than 2 years.
Operating parameters: When the filter resistance reaches 1.5-2 times the initial resistance value or the airflow velocity is below 0.35m/s, it needs to be replaced immediately.


Suggestion:
Regular monitoring: Real time monitoring of filter status through differential pressure gauge or particle counter.
Keep good records: Record the running time and performance changes to provide a basis for replacement.
Professional maintenance: It is recommended to contact the manufacturer when replacing to ensure proper operation and avoid contamination.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2003

  • Total Annual:

    3000000-4000000

  • Employee Number:

    200~300

  • Ecer Certification:

    Verified Supplier

Shenzhen ZhongJian South Environment Co., Ltd was founded in 2003. Which is the only high-tech technology company in Southern China with CNAS certification   We are mainly engaged in Designing Manufacturing, Testing & Verification, Manufacturing Processes and Quality Control, ... Shenzhen ZhongJian South Environment Co., Ltd was founded in 2003. Which is the only high-tech technology company in Southern China with CNAS certification   We are mainly engaged in Designing Manufacturing, Testing & Verification, Manufacturing Processes and Quality Control, ...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Zhong Jian South Environment Co., Ltd.
  • 9th Floor, Block C, Coolpad Building, Intersection Of Keyuan Avenue And Baoshen Road, Nanshan Gaoxin North District, Songpingshan Community, Xili Street, Shenzhen city, Guangdong, China
  • https://www.iairpurifier.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement