Origin | Bao'an District, Shenzhen City, Guangdong Province |
model 1 | CYB-F005-10(2mL) |
brand | HUACHENYANG |
model 2 | CY- B-F005-30(5mL) |
Scope of use | Preserving Sample Shipping |
model 3 | CY-B-F005-50(20mL) |
Brand Name | HUACHENYANG |
Certification | ISO13485,NMPA, |
Place of Origin | China |
View Detail Information
Explore similar products
Disposable Sampler Oral Throat Swab Disposable Sampling Tube
Spot Discovery Disposable Virus Sampling Tube Set Sampling Tubes
Disposable Medical Sterile Viral Transport Tube with Cotton tip
Nasopharyngeal Swab Disposable Sampling Tube Dry Collection Kit
Product Specification
Origin | Bao'an District, Shenzhen City, Guangdong Province | model 1 | CYB-F005-10(2mL) |
brand | HUACHENYANG | model 2 | CY- B-F005-30(5mL) |
Scope of use | Preserving Sample Shipping | model 3 | CY-B-F005-50(20mL) |
Brand Name | HUACHENYANG | Certification | ISO13485,NMPA, |
Place of Origin | China | ||
High Light | Non Inactivated Disposable Sampling Tube ,Cryopreservation Disposable Sampling Tube ,Cryopreservation Medical Sampling Tube |
Disposable Sampling Tube
Disposable sampling tube test subset cryopreservation tube inactivation detection sampling tube cell preservation solution
Introduction of disposable sampling tube:
The non-inactivated disposable sampling tube preservation solution contains a variety of solution components that are beneficial to virus cell culture, which can ensure the integrity of the virus and help increase the survival time and stability of the virus.
Disposable sampling tube features:
【Characteristics of non-inactivated virus preservation solution for disposable sampling tube】
①The non-inactivated virus preservation solution of the disposable sampling tube preserves the virus integrity and the detection rate is high. In addition to nucleic acid detection, it can also be used for other research;
②The non-inactivated virus storage solution of the disposable sampling tube can be stored at low temperature, not frozen, and does not damage the virus shell, which is convenient for long-distance transportation;
③ Disposable sampling tube virus preservation solution can be used for H1N1 influenza virus and other viruses that can be used for swab sampling;
④ The antibiotics in the non-inactivated virus preservation solution of the disposable sampling tube can effectively prevent bacterial and fungal infections;
⑤ BSA (bovine serum albumin) is added to the non-inactivated virus preservation solution in the disposable sampling tube, which can protect the virus samples and improve the separation rate.
Disposable sampling tube application:
Disposable sampling tubes are used for the collection, transportation, and storage of virus samples such as influenza, avian influenza, and coronavirus. for subsequent extraction and amplification.
Instructions for use of disposable sampling tube:
First, mark the relevant information on the label of the disposable sampling tube before taking the sample. Then use the corresponding sampling cotton swab for sampling. After taking the sample, quickly put the cotton swab into the sampling tube, break the part higher than the sampling tube, and tighten the tube cap.
The specific sampling method is as follows:
Throat swab sampling with a disposable sampling tube: wipe the bilateral pharyngeal tonsils and posterior pharyngeal wall with the sampling head, then immerse the collected specimen in the sampling solution, break off the excess part and discard, and tighten the cap of the sampling tube.
Disposable sampling tube nasal swab sampling: gently insert the sampling head into the nasal palate in the nasal passage, wait for a while, then slowly turn it out, immerse the collected specimen in the sampling solution, break off the excess part and discard it, and tighten the sampling tube cover.
Disposable sampling tube Mycoplasma, Chlamydia, and Ureaplasma urealyticum specimen sampling:
Male: Insert the sampling head into the urethra and rotate about 2cm, exit after a while, and immerse the collected sample in the sampling solution.
Female: Wipe off the cervical mucus, insert the sampling tip into the cervical canal 1-2cm for sampling, immerse the collected specimen in the sampling solution, break off the excess part and discard, and tighten the cap of the sampling tube.
Precautions:
1 After the pathogenic bacteria specimens are collected, the disposable sampling cotton swab should be completely inserted into the preservation solution to maximize the retention of the pathogenic bacteria.
2 The collected specimens must be fresh and sent for inspection in time to avoid the death of pathogenic bacteria.
3 It is forbidden to use products with damaged packaging and expired expiry date to prevent pollution.
Note: This single-use virus sampling tube is used for in vitro diagnostic purposes, and cannot be used for internal or external use in humans or animals. Ruotun
Eating can cause serious events: it is irritating to the eyes and skin. If it accidentally splashes into the eyes, rinse with water.
Packing specification:
20 servings/box, 50 servings/box, 100 servings/box
Sample requirements:
The collected specimens should be sent to the laboratory within 48 hours at 2-8°C. If they cannot be sent to the laboratory within 48 hours, they should be stored at -70°C or below. Specimens should be inoculated and separated as soon as possible after they are sent to the laboratory. They can be stored at 2-8°C within 48 hours after inoculation and separation. If it is not inoculated and separated in time, it should be stored at -70℃ or lower for storage.
Origin | Bao'an District, Shenzhen City, Guangdong Province |
Specification model | CYB-F005-10(2mL) |
brand | HUACHENYANG |
Specification model | CY- B-F005-30(5mL) |
Scope of use | Preserving Sample Shipping |
Specification model | CY-B-F005-50(20mL) |
Storage conditions and validity period:
1 The product should be stored in a clean, hygienic, dry and ventilated environment
2The temperature is 5℃~35℃
3Relative humidity<85%RH
4Product shelf life: 12 months
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2008
Total Annual:
600000000-100000000
Employee Number:
300~400
Ecer Certification:
Verified Supplier
Huachenyang Technology Co., Ltd. was established on June 2, 2008. The company has 3 major business segments. The business operation center is located in Yifang Center, Baoan District, Shenzhen, the R&D experiment center is located in Nanshan District, Shenzhen, and the manufacturing center is lo... Huachenyang Technology Co., Ltd. was established on June 2, 2008. The company has 3 major business segments. The business operation center is located in Yifang Center, Baoan District, Shenzhen, the R&D experiment center is located in Nanshan District, Shenzhen, and the manufacturing center is lo...
Get in touch with us
Leave a Message, we will call you back quickly!