China Electronic component GLE GCRH127M-101MC with Mn-Zn magnetic powder and phenolic
China Electronic component GLE GCRH127M-101MC with Mn-Zn magnetic powder and phenolic

  1. China Electronic component GLE GCRH127M-101MC with Mn-Zn magnetic powder and phenolic

Electronic component GLE GCRH127M-101MC with Mn-Zn magnetic powder and phenolic

  1. MOQ:
  2. Price:
  3. Get Latest Price
Description SMD,12.3x12.3mm Fixed Inductors RoHS
Mfr. Part # GCRH127M-101MC
Package SMD,12.3x12.3mm
Model Number GCRH127M-101MC

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Description SMD,12.3x12.3mm Fixed Inductors RoHS Mfr. Part # GCRH127M-101MC
Package SMD,12.3x12.3mm Model Number GCRH127M-101MC

Product Overview

The GCRH127M series is a type of electronic component manufactured by Shenzhen Glorious Electronic Co., Ltd. (GLE). It is designed for various applications requiring specific electrical properties, as detailed in the provided specifications.

Product Attributes

  • Brand: GLE
  • Origin: China (for Magnetic powder, Glue, Electrode), Germany (for Wire)
  • Materials: Magnetic powder (Mn-Zn), Wire (Polyurethane-system coated copper wire), Glue (Phenolic epoxy resin), Electrode (Tinned copper)
  • Color: White printing
  • Certifications: RoHS Comp.

Technical Specifications

TypePart NO.Inductance Lo (uH)Test Frequency (Hz/v)DC Resistance (m) max.Saturation Current Isat (A) Max. L/L-35%Bending TestAdhesion StrengthVibrationMechanical ShockFree Fall TestSolder AbilityResistance to Soldering HeatDielectric StrengthInsulation ResistanceLow TemperatureDry HeatDamp HeatTemperature CycleTemperature DriftOperating Temperature RangeStorage Temperature Range
GCRH127MGCRH127M-2R2MC2.2100KHz/0.25V725.5L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-4R7MC4.7100KHz/0.25V1615.9L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-5R6MC5.6100KHz/0.25V2014.0L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-6R8MC6.8100KHz/0.25V2113.3L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-8R2MC8.2100KHz/0.25V2312.2L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-100MC10100KHz/0.25V2411.2L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-150MC15100KHz/0.25V319.00L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-180MC18100KHz/0.25V355.10L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-220MC22100KHz/0.25V407.57L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-330MC33100KHz/0.25V706.22L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-390MC39100KHz/0.25V754.50L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-470MC47100KHz/0.25V805.28L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-560MC56100KHz/0.25V1304.50L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-680MC68100KHz/0.25V1054.26L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-820MC82100KHz/0.25V1433.80L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-101MC100100KHz/0.25V1633.52L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-121MC120100KHz/0.25V1701.90L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-151MC150100KHz/0.25V2473.01L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-221MC220100KHz/0.25V3762.36L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-331MC330100KHz/0.25V5742.00L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-391MC390100KHz/0.25V6501.50L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-471MC470100KHz/0.25V8611.64L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-681MC680100KHz/0.25V10801.38L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-821MC820100KHz/0.25V14701.26L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85
GCRH127MGCRH127M-102MC1000100KHz/0.25V16601.14L: within10%L: within10%L: within10%Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes.The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes.90% minimum of the surface immersed.L: within10%Without damage. 100V DC shall be applied for 60s between the terminal and the core.100Mor more. 100V DC shall be applied between the terminal and the core.L: within10%L: within10%L: within10%L: within10%2000 ppm/or less-40 ~ + 125-40 ~ + 85

2410121507_GLE-GCRH127M-101MC_C439417.pdf

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer

  • Year Established:

    2009

  • Employee Number:

    >>300

  • Ecer Certification:

    Verified Supplier

Company Profile Beijing Silk Road Enterprise Management Services Co.,Ltd. is a professional company focus on integrated circuit ic business. Beijing Silk Road will also responsible with exporting and logistic business. there is professional factory Beijing Silk Road which focus on desigining an... Company Profile Beijing Silk Road Enterprise Management Services Co.,Ltd. is a professional company focus on integrated circuit ic business. Beijing Silk Road will also responsible with exporting and logistic business. there is professional factory Beijing Silk Road which focus on desigining an...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing Silk Road Enterprise Management Services Co., Ltd.