Packaging Details | safety box |
Delivery Time | 25~30 working days |
Payment Terms | 100% TT in advance |
Supply Ability | 3~5 units per month |
spec | 60V 5A |
IP Protection Class | IP20 |
Input power | AC 380V ±10% / 60Hz |
Input active power | 6278W |
noise | <85dB |
resolution ratio | AD:16bit;DA:16bit |
Brand Name | KingPo |
Place of Origin | China |
Certification | ISO 17025 Calibration certificate |
View Detail Information
Explore similar products
HSKT10 Mechanical Shock Test Equipment For Electronic Products
72V 5A 4ch EV Battery Testing Equipment Charge And Discharge System
Weatherable Xenon Lamp Test Chamber Ultraviolet Wavelength 290nm 800nm
Burning Safety EV Battery Testing Equipment 20 Holes Mesh Screen
Product Specification
Packaging Details | safety box | Delivery Time | 25~30 working days |
Payment Terms | 100% TT in advance | Supply Ability | 3~5 units per month |
spec | 60V 5A | IP Protection Class | IP20 |
Input power | AC 380V ±10% / 60Hz | Input active power | 6278W |
noise | <85dB | resolution ratio | AD:16bit;DA:16bit |
Brand Name | KingPo | Place of Origin | China |
Certification | ISO 17025 Calibration certificate | ||
High Light | 60V 5A EV Battery Testing Equipment ,IP20 EV Battery Testing Equipment ,60V 5A Battery Charge Tester |
60V 5A EV Battery Testing Equipment
60V5A Charge And Discharge System
BTS-60V5A Standard Power Battery Testing System , Battery Continuous charge ,Battery Forced Discharge
Technical Parameter:
BTS-60V5A Battery tester |
|||||||||||||
Model Number: |
BTS- |
60 |
V |
5 |
A |
Battery tester |
Material code: |
CT-4016 |
-60V5A |
- |
NTA |
- |
P |
items |
Parameter |
||||||||||||
Input power |
AC 380V ±10% / 60Hz |
||||||||||||
Input active power |
6278 |
W |
|||||||||||
resolution ratio |
AD:16bit;DA:16bit |
||||||||||||
Input impedance |
≥100kΩ |
||||||||||||
voltage |
Constant voltage range |
0.3V~60V |
|||||||||||
Minimum discharge voltage |
3V |
||||||||||||
accuracy |
± 0.1% of FS |
||||||||||||
stability |
± 0.1% of FS |
||||||||||||
current |
Output range/channel |
0.025A~5A |
|||||||||||
accuracy |
± 0.1% of FS |
||||||||||||
Constant voltage cut-off current |
0.01A |
||||||||||||
stability |
± 0.1% of FS |
||||||||||||
Power |
Output range/channel |
300W |
|||||||||||
stability |
±0.2% of FS |
||||||||||||
time |
Current response time |
maximum current rising time20ms |
|||||||||||
working step time range |
≤(365*24)h/working step |
||||||||||||
Data record |
Record data conditions |
Minimum time interval:100ms |
|||||||||||
Minimum voltage interval:120mV |
|||||||||||||
Minimum current interval:10mA |
|||||||||||||
Record frequency |
10Hz |
||||||||||||
Charge |
Charge mode |
constant-current charge,constant-voltage charge,constant voltage and current charge |
|||||||||||
cut-off conditions |
Voltage,current,relative time,capacity,-△V |
||||||||||||
discharge |
Discharge mode |
constant current discharge, constant watt discharge |
|||||||||||
cut-off conditions |
Voltage,current,relative time,capacity,-△V |
||||||||||||
Impulse mode |
Charge |
Constant current,Constant power |
|||||||||||
Discharge |
Constant current,Constant power |
||||||||||||
Minimum impulse width |
500ms |
||||||||||||
Number of pulses |
one single pulse working step can support 32 different pulses |
||||||||||||
Continuous switch of charge and discharge |
one pulse working step can continuously switch from charge to discharge |
||||||||||||
cut-off conditions |
Voltage,relative time |
||||||||||||
DCIR test |
Support customized picking up point to perform DCIR calculation |
||||||||||||
|
|
||||||||||||
cycle |
Loop test range |
1~65535 times |
|||||||||||
Single cycle working steps |
254 |
||||||||||||
Loop nest |
Nested loop function,max 3 layers |
||||||||||||
Protection |
● Data Protection |
||||||||||||
● off-line test |
|||||||||||||
● security conditions can be set including voltage upper/lower limit,current upper/lower limit and delay time |
|||||||||||||
●anti reverse connection |
|||||||||||||
IP Protection Class |
IP20 |
||||||||||||
Channel feature |
constant current and voltage source ;double closed-loop; |
||||||||||||
Channel control mode |
independent |
||||||||||||
Current/voltage detection sampling |
four-wire connection |
||||||||||||
noise |
<85dB |
||||||||||||
data base |
MySQL centralized management of test datas |
||||||||||||
upper computer communication mode |
TCP/IP |
||||||||||||
Server disk Configuration |
500GB |
||||||||||||
Data output mode |
EXCEL 2003,2010,TXT |
||||||||||||
Server operating system |
Windows 7 |
||||||||||||
communication interface |
ethernet |
||||||||||||
Working environment requirement |
|||||||||||||
item |
parameter |
||||||||||||
working temp. range |
0℃~40℃(within25±10℃,ensured accuracy:precision drift0.005% of FS /℃) |
||||||||||||
Storage temp. range |
-10℃~50℃ |
||||||||||||
Working environment relative humidity range |
≤70% RH(no water vapor condensation) |
||||||||||||
Storage environment relative humidity range |
≤80% RH(no water vapor condensation) |
||||||||||||
Clamp specification and size |
|||||||||||||
item |
parameter |
||||||||||||
Clamp type |
Polymer clamp |
||||||||||||
Pic |
|
|
|
||||||||||
Alligator clamp |
Polymer clamp |
cable feet clamp |
|||||||||||
Pictures are for reference only,real objects shall prevail.Choose one |
|||||||||||||
Cabinet size/unit(W*D*H)(mm) |
30U(24”),730*600*1520 |
||||||||||||
Equipment pic |
|
||||||||||||
Pictures are for reference only,real objects shall prevail. |
|||||||||||||
Auxiliary channel |
type |
Temperature,voltage |
|||||||||||
Temp. range |
-25℃~110℃ |
||||||||||||
Temp. range |
±1℃ |
||||||||||||
Temp. resolution ratio |
0.1℃ |
||||||||||||
Voltage range |
-5V~5V |
||||||||||||
Voltage accuracy |
± 0.1% of FS |
||||||||||||
Available auxiliary temp.channel/channel |
customized(248 channel at most) |
||||||||||||
Available auxiliary voltage channel/channel |
customized(248 channel at most) |
||||||||||||
Protaction condition of Auxiliary channel |
● security conditions of Auxiliary channel can be set including temperature upper/lower limit,voltage upper/lower limit and delay time,voltage difference of single cell |
||||||||||||
Note:incompatible with battery that has protection plate with soft start function. |
Company Details
Business Type:
Manufacturer
Year Established:
2012
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Kingpo Technology Development Limited is a pioneer and leader of global safety testing equipment manufacturer.We offer one-stop service for worldwide labs from R&D,testing,production to after-sales service.We dedicate ourselves in achieving optimal production quality for our customers,... Kingpo Technology Development Limited is a pioneer and leader of global safety testing equipment manufacturer.We offer one-stop service for worldwide labs from R&D,testing,production to after-sales service.We dedicate ourselves in achieving optimal production quality for our customers,...
Get in touch with us
Leave a Message, we will call you back quickly!