China factories

Chat Now Send Email
China factory - Guangzhou HongCe Equipment Co., Ltd.

Guangzhou HongCe Equipment Co., Ltd.

  • China,Guangzhou ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Automatic Helium Leak Testing Machine Delivering Low False Alarm for Compressor
China Automatic Helium Leak Testing Machine Delivering Low False Alarm for Compressor

  1. China Automatic Helium Leak Testing Machine Delivering Low False Alarm for Compressor
  2. China Automatic Helium Leak Testing Machine Delivering Low False Alarm for Compressor
  3. China Automatic Helium Leak Testing Machine Delivering Low False Alarm for Compressor
  4. China Automatic Helium Leak Testing Machine Delivering Low False Alarm for Compressor

Automatic Helium Leak Testing Machine Delivering Low False Alarm for Compressor

  1. MOQ: 1 set
  2. Price: Negotiation
  3. Get Latest Price
Test Cycle 10 s/pc, up to 5 s/pc
Delivery Time 90 working days
Test Stations 2 (each station tests 2 workpieces)
Fixture Seal Verification System checks fixture seal first
Payment Terms L/C,T/T
Packaging Details Plywood
Supply Ability 1 set per 3 months
Control System PLC with 7-inch touch
Minimum Detectable Leak 1.0E-8 Pa.m3/s
Alarm Rate Control Background suppression with temperature compensation
Tracer Gas Helium 99.999%
Detection Method Helium mass spectrometry, vacuum mode
Model Number HC-HLT-800
Brand Name HongCe
Place of Origin China
Certification Calibration certificate(cost additional)

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Test Cycle 10 s/pc, up to 5 s/pc Delivery Time 90 working days
Test Stations 2 (each station tests 2 workpieces) Fixture Seal Verification System checks fixture seal first
Payment Terms L/C,T/T Packaging Details Plywood
Supply Ability 1 set per 3 months Control System PLC with 7-inch touch
Minimum Detectable Leak 1.0E-8 Pa.m3/s Alarm Rate Control Background suppression with temperature compensation
Tracer Gas Helium 99.999% Detection Method Helium mass spectrometry, vacuum mode
Model Number HC-HLT-800 Brand Name HongCe
Place of Origin China Certification Calibration certificate(cost additional)
High Light Low False Alarm Rate ,Automatic Compressor Leak Testing ,Multi Station Leak Detection

Automatic Helium Leak Testing Machine for Compressor Inspection

On a running compressor line, a false alarm is never a small event. Every good unit rejected by an unstable leak test is pulled for rework, retested and returned to the line, while the operator slowly stops trusting the test station. The HongCe HC-HLT-800 was developed around one practical goal: a result that production and quality teams can rely on the first time.

Why false alarms happen in helium leak testing

Most false alarms come from the environment and the process rather than from real leaks: background helium in the workshop air, temperature drift inside the vacuum chamber, tracer gas left over from the previous cycle, and worn fixture seals. A very sensitive detector will faithfully report all of these as failures unless the system is designed to separate them from the part itself.

How the HC-HLT-800 keeps the alarm rate low

  • Dual-chamber isolation: the detection volume is separated from ambient air so workshop helium does not reach the sensor.
  • Temperature compensation: the baseline is corrected as the chamber warms, keeping readings stable across a full shift.
  • Automatic cycle purge: residual tracer gas is cleared before the next part is loaded.
  • Fixture seal verification: the system checks the fixture seal first and reports a sealing problem instead of blaming the part.

Technical specifications

Item Specification
Detection method Helium mass spectrometry, vacuum mode
Minimum detectable leak 1.0E-8 Pa.m3/s
Test stations 2 (each station tests 2 workpieces)
Test cycle 10 s/pc, up to 5 s/pc
Tracer gas Helium 99.999%
Control system PLC with 10-inch HMI

Typical applications

The system is used for compressor shells, receivers, accumulators, heat exchangers and other sealed metal components where a dependable pass or fail decision matters more than raw sensitivity alone.

Engineering and service support

HongCe has supplied helium leak test systems to compressor and refrigeration manufacturers for more than fifteen years. Every machine is factory acceptance tested with certified helium leak standards before shipment, and our engineers support installation, operator training and calibration both on site and remotely. Spare parts and a documented calibration procedure are provided with each system.

Frequently asked questions

What leak rate can you guarantee? The standard configuration resolves 1.0E-8 Pa.m3/s; tighter targets can be discussed for specific parts.

Can the machine test parts of different sizes? Yes. The fixture can be configured for several workpiece families, and the sealing check protects the result when a part is loaded incorrectly.

Request a configuration

Send us your workpiece drawing, target leak rate and required cycle time, and our engineers will propose a configuration together with an expected false alarm performance for your process.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2003

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou HongCe Equipment Co., Ltd (hereinafter referred to as HongCe) is located in Guangzhou, China, since 2003, engaged in developing and providing test equipment and detection system for electronic & electrical products, house appliances and other products. HongCe is professionally dedicate... Guangzhou HongCe Equipment Co., Ltd (hereinafter referred to as HongCe) is located in Guangzhou, China, since 2003, engaged in developing and providing test equipment and detection system for electronic & electrical products, house appliances and other products. HongCe is professionally dedicate...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou HongCe Equipment Co., Ltd.
  • No.6-39, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou
  • https://www.iectestingequipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement