China 16-port Full Gigabit Layer 2 Managed Industrial Ethernet Switch
China 16-port Full Gigabit Layer 2 Managed Industrial Ethernet Switch

  1. China 16-port Full Gigabit Layer 2 Managed Industrial Ethernet Switch

16-port Full Gigabit Layer 2 Managed Industrial Ethernet Switch

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Packaging Details Carton
Delivery Time 7 Working Days
Payment Terms L/C, T/T
Supply Ability 3000pcs/month
Operating Temperature -40~75℃
Input Voltage 12~48VDC
Ports 8 Gigabit fiber ports,8 Gigabit copper ports
Backplane Bandwidth 56G
Housing IP40 protection, metal
Warranty 5 years
Dimension (W x H x D) 70mm×160mm×130mm
Place of Origin Shenzhen, China
Brand Name 3onedata
Certification CE, FCC, RoHS
Model Number IES7116G-8GS

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Packaging Details Carton Delivery Time 7 Working Days
Payment Terms L/C, T/T Supply Ability 3000pcs/month
Operating Temperature -40~75℃ Input Voltage 12~48VDC
Ports 8 Gigabit fiber ports,8 Gigabit copper ports Backplane Bandwidth 56G
Housing IP40 protection, metal Warranty 5 years
Dimension (W x H x D) 70mm×160mm×130mm Place of Origin Shenzhen, China
Brand Name 3onedata Certification CE, FCC, RoHS
Model Number IES7116G-8GS
High Light redundant ethernet switchindustrial gigabit ethernet switch

16-port Full Gigabit Layer 2 Managed Industrial Ethernet Switch

 

Introduction

IES7116G-8GS is 16-port full Gigabit layer 2 managed industrial Ethernet switches. This product provides Gigabit copper port and Gigabit SFP slot. It adopts DIN-Rail mounting to meet the requirements of different application scenes.

 

Features and Benefits

 

SNMPv1/v2c/v3 is used for network management of various levels

RMON can be used for efficient and flexible network monitoring

Port mirroring can conduct data analysis and monitoring, which is convenient for online debugging

QoS supports real-time traffic classification and priority setting

LLDP can achieve automatic topology discovery, which is convenient for visual management

DHCP server and client can be used for distributing IP address

File management is convenient for the device rapid configuration and online upgrading

Log management has recorded booting, operation and connection information

Bandwidth management can reasonably distribute network bandwidth, preventing unpredictable network status

Port statistics can be used for port real-time traffic statistics

Support Console/Telnet/WEB management method

User password can conduct user hierarchical management to improve the device management security

Anti-attack control, ACL and 802.1X authentication can enhance the network flexibility and security

E-mail alarm is convenient for immediate fault discovery during remote management

Relay alarm is convenient for troubleshooting of construction site

Storm suppression can restrain the broadcast, unknown multicast and unknown unicast

SSHD configuration can achieve data transmission encryption, preventing DNS and IP spoofing

TELNET and HTTPS configuration can guarantee the data access security

VLAN is used for simplifying network planning

Port trunking and LACP can increase network bandwidth and enhance the reliability of network connection to achieve optimum bandwidth utilization

IGMP Snooping, GMRP and static multicast can be used for filtering multicast traffic to save the network bandwidth

Support Port Isolation in the same VLAN

SW-Ring and STP/RSTP/MSTP can achieve network redundancy, preventing network storm

Network Diagnosis and Troubleshooting can be conducted via Ping, Traceroute and Port Loopback

 

Specification

 

 

Standard

&

Protocol

 

IEEE 802.3 for 10Base-T

IEEE 802.3u for 100Base-TX

IEEE 802.3ab for 1000Base-T

IEEE 802.3z for 1000Base-X

IEEE 802.3x for Flow Control

IEEE 802.1D for Spanning Tree Protocol

IEEE 802.1w for Rapid Spanning Tree Protocol

IEEE 802.1s for Multiple Spanning Tree Protocol

IEEE 802.1Q for VLAN

IEEE 802.1p for CoS

IEEE 802.1X for 802.1X Authentication

IEEE 802.1AB for LLDP

IEEE 802.3ad for LACP

 

Management

 

SNMP v1/v2c/v3 Centralized Management of Equipment, RMON, Port Mirroring, QoS, LLDP, DHCP Server, DHCP Client, File Management, Log Management, Port Statistics

 

Security

 

Classification of User Permissions, Anti-attack Control, ACL, 802.1X Authentication, Port Alarm, Power Supply Alarm, E-mail Alarm, Storm Suppression, SSHD Configuration, Telnet Configuration, HTTPS Configuration

 

Switch Function

 

802.1Q Vlan, Static/Dynamic Port Aggregation, Bandwidth Management, Flow Control, Port Isolation

 

 

Unicast / Multicast

 

Static Multicast, GMRP, IGMP-Snooping

 

Redundancy

Protocol

 

 

SW-Ring, STP/RSTP/MSTP

 

 

Fault

Diagnosis

 

Ping, Traceroute, Port Loopback
Time Management

 

SNTP

 

Interface

 

Copper port: 10/100/1000Base-T(X), RJ45, Automatic Flow Control, Full/half Duplex Mode, MDI/MDI-X Autotunning

SFP slot: 1000Base-SFP

Console port: CLI command line management port (RS-232), RJ45

Alarm port: 2-pin 7.62mm pitch terminal blocks, support 1 relay alarm output, current carrying capacity 1A@24VDC or 0.5A@120VAC

 

LED Indicator

 

Running Indicator, Port Indicator, Power Supply Indicator, Alarm Indicator

 

Switch

Property

 

Transmission mode: store and forward

MAC address: 16K

Packet buffer size: 12Mbit

Backplane bandwidth: 56G

Switch time delay: < 5μs

 

Power

Requirement

 

12~48VDC, 4-pin 7.62mm pitch terminal blocks

dual power supply redundancy, reverse polarity protection, nonpolarity

 

 

Power

Consumption

 

No-load: 10.99W@24VDC

Full-load: 20.69W@24VDC

Environmental

Limit

 

Operating temperature range: -40~75℃

Storage temperature range: -40~75℃

Relative humidity: 5%~95%(no condensation)

 

Physical Characteristic

 

Housing: IP40 protection, metal

Installation: DIN-Rail mounting

Weight: 1.1kg

Dimension (W x H x D): 70mm×160mm×130mm

 

Industrial

Standard

 

IEC 61000-4-2 (ESD) ,Level 4

Air discharge: ±15kV

Contact discharge: ±8kV

 

IEC 61000-4-4 (EFT), Level 4

Power supply: ±4kV

Ethernet interface: ±2kV

Relay: ±4kV

 

IEC 61000-4-5 (Surge), Level 4

Power supply: common mode ±4kV, differential mode ±2kV

Relay: common mode ±4kV, differential mode ±2kV

 

Shock: IEC 60068-2-27

Free fall: IEC 60068-2-32

Vibration: IEC 60068-2-6

 

Certification

 

CE, FCC, RoHS

 

Warranty

 

5 years

 

Ordering Information

 

Available Models Gigabit SFP Slot Gigabit Copper Port Power Supply Range
IES7116G-8GS 8 8

12~48VDC

dual power supply

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2001

  • Total Annual:

    20000000-30000000

  • Employee Number:

    300~500

  • Ecer Certification:

    Active Member

Founded in 2001 3onedata has been dedicated in industrial communication field for over 18 years. We are a National High-tech Enterprise integrating with R&D, manufacturing, marketing and service so as to provide complete business support to our worldwide partners and customers. Until now we ... Founded in 2001 3onedata has been dedicated in industrial communication field for over 18 years. We are a National High-tech Enterprise integrating with R&D, manufacturing, marketing and service so as to provide complete business support to our worldwide partners and customers. Until now we ...

+ Read More

Get in touch with us

  • Reach Us
  • 3onedata Co., Ltd.
  • 3/B, Zone 1, Baiwangxin High Technology Industrial park,Song Bai Road, Nanshan District, Shenzhen, 518108, China
  • https://www.iinetcom.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement