| Sensor Type | Internal (961A) / External probe (961B, 961C) |
| Shipping Term | International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/Sea Freight / Air Freight / International Special Line |
| Payment Terms | L/C,D/A,D/P,T/T |
| Logging Interval | 10 s to 24 hr, user configurable |
| Report Export | PDF direct via USB; Excel and TXT via Flukelog software |
| Delivery Time | 3-5Workdays |
| Data Capacity | 32,000 data sets |
| Freight Charge | For Industrial Equipment (E.G., PLC Modules, Inverters..), Shipping Cost Varies By Package Weight/Volume And Delivery Location. Contact Our Sales Team For A Customized Shipping Solution And Quot |
| Packaging Details | Original |
| Humidity Measurement | 0 to 100 %RH, ±3 %RH at 20-80 %RH (961A, 961C); not available on 961B |
| Temperature Range | -30 to 70 C (961A) / -85 to 150 C (961B) / -40 to 85 C (961C) |
| Model Number | Fluke 961A 961B 961C |
| Brand Name | Fluke |
| Certification | IEC 61010-1、IP65、IEC 61326-1 、 |
View Detail Information
Explore similar products
Endress+Hauser Promass F Flowmeter & Levelflex FMP51 Level Transmitter
Fluke 724 Temperature Calibrator for Sensor Verification, Loop Power and 4-20 mA
Fluke 2052 2062 Advanced Wire Tracer Kit - CAT IV 600V Circuit & Breaker Finder
Fluke 922/KIT Airflow Meter - Differential Pressure & Pitot Tube Airflow Tester
Product Specification
| Sensor Type | Internal (961A) / External probe (961B, 961C) | Shipping Term | International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/Sea Freight / Air Freight / International Special Line |
| Payment Terms | L/C,D/A,D/P,T/T | Logging Interval | 10 s to 24 hr, user configurable |
| Report Export | PDF direct via USB; Excel and TXT via Flukelog software | Delivery Time | 3-5Workdays |
| Data Capacity | 32,000 data sets | Freight Charge | For Industrial Equipment (E.G., PLC Modules, Inverters..), Shipping Cost Varies By Package Weight/Volume And Delivery Location. Contact Our Sales Team For A Customized Shipping Solution And Quot |
| Packaging Details | Original | Humidity Measurement | 0 to 100 %RH, ±3 %RH at 20-80 %RH (961A, 961C); not available on 961B |
| Temperature Range | -30 to 70 C (961A) / -85 to 150 C (961B) / -40 to 85 C (961C) | Model Number | Fluke 961A 961B 961C |
| Brand Name | Fluke | Certification | IEC 61010-1、IP65、IEC 61326-1 、 |
| High Light | Fluke 961A temperature humidity data logger ,USB PDF cold chain data logger ,refrigerator monitoring humidity logger | ||
| Item | 961A | 961B | 961C |
|---|---|---|---|
| Sensor type | Internal | External probe | External probe |
| Temperature range | −30.0 to 70.0 °C | −85.0 to 150.0 °C | −40.0 to 85.0 °C |
| Temperature accuracy | ±0.4 °C | ±(0.3 + 0.005 × |reading|) °C | ±0.4 °C |
| Temperature resolution | 0.1 °C | 0.1 °C | 0.1 °C |
| Humidity range | 0 to 100.0 %RH | Not available | 0 to 100.0 %RH |
| Humidity accuracy | ±3 %RH (20–80 %RH @ 25 °C); ±5 %RH (<20 %RH, >80 %RH @ 25 °C) | — | ±3 %RH (20–80 %RH @ 25 °C); ±5 %RH (<20 %RH, >80 %RH @ 25 °C) |
| Humidity resolution | 0.1 %RH | — | 0.1 %RH |
| Weight (with battery) | 60 g | 88 g | 78 g |
| Best for | Fridges, cabinets, ambient rooms | Ultra-low freezers, autoclaves, ovens | Cold rooms, chillers, pharma storage |
No — the PDF report is generated by the logger itself. Plug the USB connector into any Windows PC and a formatted PDF report opens, with min/max/average, alarm events and the full trace. FlukeLog desktop software is only needed when you want Excel or TXT export, custom PDF templates, chart views or remote configuration of start time, interval and alarm limits.
Sensor placement and range, not data features. The 961A has an internal sensor for −30 to 70 °C plus humidity. The 961B has an external probe reaching −85 to 150 °C and no humidity channel. The 961C has an external probe for −40 to 85 °C plus humidity. All three share the same 32,000-point memory, 10 s to 24 hr interval, USB PDF output and IP65 housing.
No. The 961A is rated −30 to 70 °C only. Putting an internal-sensor logger into a ULT freezer exceeds its range and voids the reading. For −80 °C work you need the 961B with its external probe, which covers −85 to 150 °C. This is also why the logger body itself is only rated −30 to 70 °C on every model — the body stays outside, the probe goes in.
Yes — the data path is FDA 21 CFR Part 11 compliant and traceable. Reports carry device identity and timestamps, alarms are recorded as single or cumulative events, and readings cannot be edited after the fact. That is the combination auditors ask for under GDP/GMP and HACCP. Note this is a data-integrity compliance statement, not a calibration certificate.
One year, and yes — it is a user-replaceable CR2450 coin cell. The one-year figure assumes a 15-minute logging interval at 25 °C. Logging every 10 seconds in a cold room will shorten it; estimate roughly proportional to interval. Swap the cell and the stored data is retained.
±0.4 °C on 961A and 961C; ±(0.3 + 0.005 × |reading|) °C on 961B. Resolution is 0.1 °C and 0.1 %RH. The published figures are manufacturer specifications; the datasheet does not state an accredited calibration certificate in the box, so if your SOP requires ISO 17025 traceability, budget for a third-party calibration at purchase.
Company Details
Business Type:
Manufacturer,Exporter
Ecer Certification:
Verified Supplier
About Us: Beyond Components, We Deliver Certainty Shanghai Fradwell Industrial Automation Co., Ltd — Your Trusted Partner in Industrial Automation. With over two decades of industry expertise, we have evolved from a traditional supplier into a one-stop integrated solutions provider f... About Us: Beyond Components, We Deliver Certainty Shanghai Fradwell Industrial Automation Co., Ltd — Your Trusted Partner in Industrial Automation. With over two decades of industry expertise, we have evolved from a traditional supplier into a one-stop integrated solutions provider f...
Get in touch with us
Leave a Message, we will call you back quickly!