China Schneider LC1D65M7C TeSys Deca Contactor 80A Rated Current With DIN Rail
China Schneider LC1D65M7C TeSys Deca Contactor 80A Rated Current With DIN Rail

  1. China Schneider LC1D65M7C TeSys Deca Contactor 80A Rated Current With DIN Rail
  2. China Schneider LC1D65M7C TeSys Deca Contactor 80A Rated Current With DIN Rail
  3. China Schneider LC1D65M7C TeSys Deca Contactor 80A Rated Current With DIN Rail

Schneider LC1D65M7C TeSys Deca Contactor 80A Rated Current With DIN Rail

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Number_of_Inputs 14
Dimensions 90 x 100 x 75 mm
Manufacturer Siemens
Output Typt Relay
Model S7-1200
Weight 0.5 kg
Input_Voltage 24 V DC
Power Supply Voltage 100 – 240VAC.
Output Points 16DO
Payment Terms T/T
Supply Ability 1000
Delivery Time 5-7 days
Mounting_Type DIN Rail
Color Normal
CPU_Speed 100 MHz
Output Method Transistor
Application Oil and Gas Factory
Actual Price based on offer
Brand Name Schneider
Model Number LC1D65M7C
Certification Brand new original

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Number_of_Inputs 14 Dimensions 90 x 100 x 75 mm
Manufacturer Siemens Output Typt Relay
Model S7-1200 Weight 0.5 kg
Input_Voltage 24 V DC Power Supply Voltage 100 – 240VAC.
Output Points 16DO Payment Terms T/T
Supply Ability 1000 Delivery Time 5-7 days
Mounting_Type DIN Rail Color Normal
CPU_Speed 100 MHz Output Method Transistor
Application Oil and Gas Factory Actual Price based on offer
Brand Name Schneider Model Number LC1D65M7C
Certification Brand new original
High Light LC1D65M7C ,TeSys Deca Contactor 80A ,Schneider TeSys Deca Contactor

Product Series
TeSys Deca
Product Series
TeSys Deca
Product Type
Contactor
Short Product Name
LC1D
Contactor Applications
Applications: Non-inductive or slightly inductive loads, resistance furnaces
Applications: AC loads with a power factor greater than or equal to 0.95
Usage Category
AC-4
AC-1
AC-3
AC-3e
Number of Poles
3P
Rated Operating Voltage [Ue]
Power Circuit: <= 690 V AC 25...400 Hz
Power Circuit: <= 300 V DC
Rated Operating Current [Ie]
80 A (when operating temperature <= 60 °C) when operating voltage <= 440 V AC
AC-1 for power circuit
65 A (when operating temperature <= 60 °C) when operating voltage <= 440 V AC
AC-3 for power circuit
65 A (when operating temperature <= 60 °C) when operating voltage <= 440 V AC
AC-3e for power circuit
Control Circuit Voltage [Uc]
220 V AC 50/60 Hz

Supplementary Information
Motor Power (kW)
11 kW when operating voltage <= 400 V AC 50/60 Hz (AC-4)
37 kW when operating voltage <= 500 V AC 50/60 Hz (AC-3)
18.5 kW when operating voltage <= 220/240 V AC 50/60 Hz (AC-3)
30 kW when operating voltage <= 380/400 V AC 50/60 Hz (AC-3)
37 kW when operating voltage <= 660/690 V AC 50/60 Hz (AC-3)
37 kW when operating voltage <= 415/440 V AC 50/60 Hz (AC-3)
37 kW when operating voltage <= 500 V AC 50/60 Hz (AC-3e)
18.5 kW when operating voltage <= 220/240 V AC 50/60 Hz (AC-3e)
30 kW when operating voltage <= 380/400 V AC 50/60 Hz (AC-3e)
37 kW when operating voltage <= 660/690 V AC 50/60 Hz (AC-3e)
37 kW when operating voltage <= 415/440 V AC 50/60 Hz (AC-3e)
Model
LC1D
Circuit Contact Type
3 NO
Protective Cover
With
Rated Thermal Current [Ith]
10 A (when operating temperature <= 60 °C) for signal circuits
80 A (when operating temperature <= 60 °C) for power circuits
Rated Short-Time Withstand Current [Icw]
520 A when operating temperature <= 40 °C for 10 s for power circuits
900 A When operating temperature <= 40 °C, continuous for 1 s for power circuits

110 A When operating temperature <= 40 °C, continuous for 10 minutes for power circuits

260 A When operating temperature <= 40 °C, continuous for 1 minute for power circuits

100 A Continuous for 1 s for signal circuits

120 A Continuous for 500 ms for signal circuits

140 A Continuous for 100 ms for signal circuits

Fuses for use with relays

10 A gG, for signal circuits, conforming to IEC 60947-5-1

125 A gG When operating voltage <= 690 V, type 2, for power circuits

160 A gG When operating voltage <= 690 V, type 1, for power circuits

Average impedance

1 mΩ - Ith 80 A 50 Hz for power circuits

Rated insulation voltage [Ui]

Signal circuits: 690 V, conforming to IEC 60947-1
Power Circuit: 1000 V compliant with IEC 60947-4-1
Overvoltage Category:
III
Pollution Degree:
3
Rated Impulse Withstand Voltage [Uimp]:
6 kV compliant with IEC 60947
Safety and Reliability Class:
B10d = 1,369,863 cycles for contactors with nominal loads compliant with EN/ISO 13849-1
B10d = 20,000,000 cycles for contactors with mechanical loads compliant with EN/ISO 13849-1
Mechanical Life:
6 Mcycles
Electrical Life:
1.5 Mcycles <= 440 V under 80 A AC-1 Ue conditions
1.5 Mcycles <= 440 V under 65 A AC-3 Ue conditions
2.5 Mcycles 660/690 V under 42 A AC-3 Ue conditions
1.5 Mcycles 65 A AC-3e Ue conditions <= 440 V
2.5 Mcycles 42 A AC-3e Ue conditions 660/690 V
Control circuit characteristics
AC at 50/60 Hz
Surge suppression module
No built-in surge suppression module
Control voltage limit
0.3...0.6 Uc (-40…60 °C): Coil release 50/60 Hz
0.8...1.1 Uc (-40…60 °C): Coil start 50 Hz
0.85...1.1 Uc (-40…60 °C): Coil start 60 Hz

(~50Hz start) power consumption (VA)
245 VA 60 Hz cos phi 0.75 (at 20 °C)
245 VA 50 Hz cos phi 0.75 (at 20 °C)

(~50Hz hold) power consumption (VA)
26 VA 60 Hz cos phi 0.3 (at 20 °C)

26 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation

6…10 W at 50/60 Hz

Action time

20...26 ms Closing

8...12 ms Breaking

Maximum operating frequency

3600 times/hour at 60 °C

Wiring capability

Control circuit: Bolted 1 1…4 mm² Cable type: Flexible wire without terminals

Control circuit: Bolted 2 1…4 mm² Cable type: Flexible wire without terminals

Control circuit: Bolted 2 1…2.5 mm² Cable type: Flexible wire with terminals

Control circuit: Bolted 1 1…4 mm² Cable type: Hard wire without terminals

Control circuit: Bolted 2 1…4 mm² Cable type: Hard wire without terminals

Control circuit: Bolt Tightening 1 1…2.5 mm² Cable Type: Flexible Wire with Terminal Block

Power Circuit: Terminal Block 1 2.5…25 mm² Outer Diameter of Connector Ø: 13 mm Cable Type: Flexible Wire without Terminal Block

Power Circuit: Terminal Block 2 2.5…16 mm² Outer Diameter of Connector Ø: 13 mm Cable Type: Flexible Wire without Terminal Block

Power Circuit: Terminal Block 1 2.5…25 mm² Outer Diameter of Connector Ø: 13 mm Cable Type: Flexible Wire with Terminal Block

Power Circuit: Terminal Block 2 2.5…10 mm² Outer Diameter of Connector Ø: 13 mm Cable Type: Flexible Wire with Terminal Block

Power Circuit: Terminal Block 1 2.5…25 mm² Outer Diameter of Connector Ø: 13 mm Cable Type: Solid Wire without Terminal Block

Power Circuit: Terminal Block 2 2.5…16 mm² Connector outer diameter Ø: 13 mm Cable type: Hard wire, without terminals
Tightening torque
Control circuit: 1.2 N.m via bolt tightening with screwdriver Ø 6 flathead
Control circuit: 1.2 N.m via bolt tightening with screwdriver No. 2 Phillips head screw
Power circuit: 5 N.m via bolt tightening with screwdriver Ø 6...8 mm slotted head
Power circuit: 5 N.m via cable connector tightening with screwdriver Ø 8 slotted head screw: M6
Power circuit: 5 N.m via cable connector tightening with screwdriver No. 3 Phillips head screw: M6
Control circuit: 1.2 N.m via bolt tightening with screwdriver No. 2
Auxiliary contact type
Type Mechanical connection 1 NO + 1 NC Complies with IEC 60947-5-1
Type Mirror image of main contact state 1 NC Complies with IEC 60947-4-1 Auxiliary Contacts Available on Each Contactor:
1 NO + 1 NC
Signal Circuit Frequency:
25...400 Hz
Minimum Switching Current [1 min]:
5 mA for signal circuit
Insulation Resistance:
> 10 MΩ for signal circuit
Non-overlap Time:
1.5 ms de-energization between NC and NO contacts
1.5 ms energization between NC and NO contacts
Mounting Method:
DIN rail mounting
Base plate mounting
Environment:
Complies with:
IEC 60947-1
IEC 60947-4-1
GB/T 14048.4
Product Certifications:
CE
UKCA
CCC
IP Protection Rating:
IP2X (Front panel, main circuit applicable, compliant with IEC 60529)
Protection Measures:
TH (Complies with IEC 60068-2-30)
Ambient Air Temperature:
-40…60 °C (Operating),
60…70 °C (Derating),
-60…80 °C °C Storage
Operating Altitude
3000 m No Degradation
Fire Resistance and Resistance to Abnormal High Temperatures
850 °C Complies with IEC 60695-2-11
Shock and Vibration Resistance
Shock Resistance: Contact Open (2 gn (5...300 Hz)) Complies with IEC 60068-2-6
Shock Resistance: 11 ms Contact Open (8 gn) Complies with IEC 60068-2-27
Shock Resistance: 11 ms Contact Close (10 gn) Complies with IEC 60068-2-27
Shock Resistance: Contact Close (3 gn (5...300 Hz)) Complies with IEC 60068-2-6
Height
127 mm
Width
75 mm
Depth
119 mm
Net Weight
1.4 kg

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Manufacturer,Agent,Exporter,Trading Company,Seller

  • Year Established:

    2018

  • Total Annual:

    2,000,000$-3,000,000$

  • Employee Number:

    15~20

  • Ecer Certification:

    Verified Supplier

Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd. Founded in 2018 | Headquartered in Fengdong New Town, Xi'an, Shaanxi Province, China Company Overview Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd. is a leading manufacturer and supplier of industrial automation contr... Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd. Founded in 2018 | Headquartered in Fengdong New Town, Xi'an, Shaanxi Province, China Company Overview Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd. is a leading manufacturer and supplier of industrial automation contr...

+ Read More

Get in touch with us

  • Reach Us
  • Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
  • F1-803, Guorun Silu Jin Rong Zhongxin, Qindu District, Xianyang City, Shaanxi Province
  • https://www.industrial-controlautomation.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement