China factories

Chat Now Send Email
China factory - Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.

Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.

  • China,Xianyang ,Shaanxi
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China 16 Channel Analog Input Communication Card Module Honeywell 51403776-100
China 16 Channel Analog Input Communication Card Module Honeywell 51403776-100

  1. China 16 Channel Analog Input Communication Card Module Honeywell 51403776-100
  2. China 16 Channel Analog Input Communication Card Module Honeywell 51403776-100

16 Channel Analog Input Communication Card Module Honeywell 51403776-100

  1. MOQ: 1 pcs
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 10000 pcs
Delivery Time 5-7 days
Supportedindustries Oil & Gas, Chemical, Power Generation, Manufacturing
Securityfeatures Role-based access control, encryption
Architecture Distributed, modular
Datalogging Comprehensive data historian and logging
Redundancy Yes, supports redundant controllers and communication paths
Integrationcapability Integrates with SCADA, PLC, and MES systems
Function Automated control of industrial processes
Realtimeprocessing Yes, real-time data acquisition and control
Userinterface Graphical Human-Machine Interface (HMI)
Maintenance Remote diagnostics and predictive maintenance support
Scalability High, supports expansion
Communicationprotocol Supports multiple protocols (e.g., Ethernet/IP, Modbus, Profibus)
Alarmmanagement Advanced alarm and event management
Controltype Closed-loop control
Productname Distributed Control System (DCS)
Brand Name Honeywell
Model Number 51403776-100
Certification Brand new original

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 10000 pcs
Delivery Time 5-7 days Supportedindustries Oil & Gas, Chemical, Power Generation, Manufacturing
Securityfeatures Role-based access control, encryption Architecture Distributed, modular
Datalogging Comprehensive data historian and logging Redundancy Yes, supports redundant controllers and communication paths
Integrationcapability Integrates with SCADA, PLC, and MES systems Function Automated control of industrial processes
Realtimeprocessing Yes, real-time data acquisition and control Userinterface Graphical Human-Machine Interface (HMI)
Maintenance Remote diagnostics and predictive maintenance support Scalability High, supports expansion
Communicationprotocol Supports multiple protocols (e.g., Ethernet/IP, Modbus, Profibus) Alarmmanagement Advanced alarm and event management
Controltype Closed-loop control Productname Distributed Control System (DCS)
Brand Name Honeywell Model Number 51403776-100
Certification Brand new original
High Light 16 Channel Communication CardCommunication Card Module51403776-100
51403776-100 Honeywell Communication Card Module
Core Technical Specifications
Model 51403776-100
Manufacturer Honeywell
Type 16-Channel Analog Input Module (AI)
Applicable Systems Experion® PKS C300 Controller
Input Channels 16 Independent 4–20mA (Active/Passive)
Protocol Supports HART
Accuracy ±0.1% (Full Scale)
Isolation ≥500V DC (Channel-to-Channel/Channel-to-Ground)
Update Cycle Fastest 100ms (Configurable)
Communication I/O Link → C300 → FTE Network
Operating Temperature 0°C~+60°C
Mounting C300 I/O Rack, Hot-Swap
Protection IP20 (Control Room Environment)
Key Features and Benefits
  • High-Density Integration: 16 channels per slot, optimizing rack space utilization
  • High-Precision Acquisition: ±0.1% full-scale accuracy, compatible with Advanced Process Control (APC)
  • Native HART Support: Directly reads transmitter diagnostic information without multiplexers
  • Superior Anti-Interference: Channel-level isolation suppresses common-mode interference and ground loop noise
  • High Availability: Supports hot-swapping and online diagnostics with FTE redundant networks
Typical Industrial Applications
  • Refining/Chemical: Tower bottom temperature, feed flow rate, and pressure acquisition
  • Power Generation: Boiler drum water level monitoring and denitrification system parameters
  • Pharmaceutical/Food: Level control of fermenters, reactors, and storage tanks
  • Oil & Gas: Pressure/flow monitoring of LNG receiving stations and long-distance pipelines
Compatibility and Replacements
Compatible Base: 51403760-100 (IOTA Base)
Same Series Output: 51403780-100 (16-channel AO)
Replacement/Compatibility: 51403777-100 (8-channel high-voltage AI)
Installation and Maintenance Guidelines
Critical Installation Notes:
• Requires dedicated IOTA docking station (e.g., 51403760-100)
• Power off recommended for initial installation
• Hot-swapping requires setting to Maintenance Mode first
• Channel status (open circuit/over-range) can be diagnosed online using Experion PKS engineer station

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Manufacturer,Agent,Exporter,Trading Company,Seller

  • Year Established:

    2018

  • Total Annual:

    2,000,000$-3,000,000$

  • Employee Number:

    15~20

  • Ecer Certification:

    Verified Supplier

.gtr-container-7f3a9e { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; box-sizing: border-box; font-size: 14px; } .gtr-container-7f... .gtr-container-7f3a9e { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; box-sizing: border-box; font-size: 14px; } .gtr-container-7f...

+ Read More

Get in touch with us

  • Reach Us
  • Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
  • F1-803, Guorun Silu Jin Rong Zhongxin, Qindu District, Xianyang City, Shaanxi Province
  • https://www.industrial-controlautomation.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement